1070-CD and 1070-CR are two conditions of the same steel grade, 1070: CD (cold drawn) versus CR (cold rolled). The chemistry is identical, so every difference below comes from the condition. 1070-CD is the stronger of the two: yield strength 720 MPa (104 ksi) against 650 MPa (94.3 ksi) for 1070-CR, about 11% more; tensile strength follows at 830 MPa (120 ksi) vs 780 MPa (113 ksi). 1070-CD is the more ductile: elongation 9% versus 8% for 1070-CR, and 1070-CD is harder (248 HB vs 225 HB). 1070-CD runs hotter in service (300°C vs 200°C continuous).

1070-CDChoose it when strength drives the design, or when the part is bent, formed or impact-loaded.

1070-CD vs 1070-CR: properties

1070-CD1070-CR

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

830 MPa120 ksi
780 MPa113 ksi

Yield Strength (0.2% offset)

720 MPa104 ksi
650 MPa94.3 ksi

Elongation at Break

9%
8%

Shear Strength

450 MPa65.3 ksi
500 MPa72.5 ksi

Fatigue Strength (Endurance Limit)

380 MPa55.1 ksi
350 MPa50.8 ksi

Fracture Toughness (K_IC)

45 MPa·√m41 ksi·√in
40 MPa·√m36.4 ksi·√in

Charpy V-Notch Impact (RT)

12 J8.9 ft·lbf
8 J5.9 ft·lbf

Hardness, Brinell

248 HB
225 HB

Hardness, Rockwell B

93 HRB
98 HRB

Hardness, Vickers

211 HV
236 HV

Same in both: Elastic (Young's) Modulus 205 GPa29.7 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29 · Reduction in Area 25%

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,425°C2,597 °F · Liquidus Temperature 1,480°C2,696 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

49 W/m·K28.3 BTU/hr·ft·°F
48 W/m·K27.7 BTU/hr·ft·°F

Max Service Temperature (continuous)

300°C572 °F
200°C392 °F

Same in both: Specific Heat Capacity 470 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 11.5 µm/m·K6.4 µin/in·°F · Latent Heat of Fusion 250 J/g107 BTU/lb · Min Service Temperature -20°C-4 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 9 % IACS · Electrical Resistivity 1.9×10⁻⁷ Ω·m7.48 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.61 V · Corrosion Resistance 9 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

42 / 100
40 / 100

Weldability

20 / 100
15 / 100

Formability (cold)

20 / 100
25 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 50% · Brazeability / Solderability 45 / 100 · Polishability 65 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 25 MJ/kg10,748 BTU/lb · Embodied Carbon (primary production) 2.1 kg CO₂/kg · Embodied Water 45 L/kg5.4 gal/lb · Typical Recycled Content 25%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale1070

1070-CD vs 1070-CR — frequently asked

Is 1070-CD stronger than 1070-CR?

Yes. 1070-CD has a typical yield strength of 720 MPa (104 ksi) against 650 MPa (94.3 ksi) for 1070-CR — about 11% more. Tensile strength is 830 MPa (120 ksi) vs 780 MPa (113 ksi).

Which condition does FabDigit quote by default, CD or CR?

HR is the default 1070 condition in the FabDigit quote flow (neither CD nor CR). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which welds better, 1070-CD or 1070-CR?

1070-CD. Its weldability rates poor (20/100) against poor (15/100) for 1070-CR.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 1070-CD and 1070-CR side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.