Steel 1060 Annealed vs 1060-CR

Steel · 1060 temper comparison

1060 Annealed and 1060-CR are two conditions of the same steel grade, 1060: Annealed versus CR (cold rolled). The chemistry is identical, so every difference below comes from the condition. 1060-CR is the stronger of the two: yield strength 700 MPa (102 ksi) against 372 MPa (54 ksi) for 1060 Annealed, about 88% more; tensile strength follows at 830 MPa (120 ksi) vs 626 MPa (90.8 ksi). In exchange, 1060 Annealed is the more ductile: elongation 22% versus 8% for 1060-CR, and 1060-CR is harder (250 HB vs 179 HB). 1060 Annealed runs hotter in service (300°C vs 200°C continuous).

1060 AnnealedChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

1060-CRChoose it when strength drives the design.

1060 Annealed vs 1060-CR: properties

1060 Annealed1060-CR

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

626 MPa90.8 ksi
830 MPa120 ksi

Yield Strength (0.2% offset)

372 MPa54 ksi
700 MPa102 ksi

Elongation at Break

22%
8%

Reduction in Area

38%
25%

Shear Strength

420 MPa60.9 ksi
500 MPa72.5 ksi

Fatigue Strength (Endurance Limit)

280 MPa40.6 ksi
370 MPa53.7 ksi

Fracture Toughness (K_IC)

45 MPa·√m41 ksi·√in
40 MPa·√m36.4 ksi·√in

Charpy V-Notch Impact (RT)

11 J8.1 ft·lbf
8 J5.9 ft·lbf

Hardness, Brinell

179 HB
250 HB

Hardness, Rockwell B

89 HRB
100 HRB

Hardness, Vickers

210 HV
263 HV

Same in both: Elastic (Young's) Modulus 205 GPa29.7 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,400°C2,552 °F · Liquidus Temperature 1,470°C2,678 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

49 W/m·K28.3 BTU/hr·ft·°F
48 W/m·K27.7 BTU/hr·ft·°F

Max Service Temperature (continuous)

300°C572 °F
200°C392 °F

Same in both: Specific Heat Capacity 470 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 11.3 µm/m·K6.3 µin/in·°F · Latent Heat of Fusion 250 J/g107 BTU/lb · Min Service Temperature -20°C-4 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

9.6 % IACS
9.5 % IACS

Electrical Resistivity

1.8×10⁻⁷ Ω·m7.09 µΩ·in
1.81×10⁻⁷ Ω·m7.13 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.61 V · Corrosion Resistance 10 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

48 / 100
40 / 100

Machinability Rating (AISI 1212 = 100 %)

60%
55%

Formability (cold)

40 / 100
20 / 100

Same in both: Weldability 25 / 100 · Castability 45 / 100 · Brazeability / Solderability 55 / 100 · Polishability 65 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 25 MJ/kg10,748 BTU/lb · Embodied Carbon (primary production) 1.9 kg CO₂/kg · Embodied Water 45 L/kg5.4 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale1060

1060 Annealed vs 1060-CR — frequently asked

Is 1060-CR stronger than 1060 Annealed?

Yes. 1060-CR has a typical yield strength of 700 MPa (102 ksi) against 372 MPa (54 ksi) for 1060 Annealed — about 88% more. Tensile strength is 830 MPa (120 ksi) vs 626 MPa (90.8 ksi).

Which condition does FabDigit quote by default, Annealed or CR?

HR is the default 1060 condition in the FabDigit quote flow (neither Annealed nor CR). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 1060 Annealed or 1060-CR?

1060 Annealed, by a small margin. Both rate fair for machinability — 48/100 against 40/100 for 1060-CR.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 1060 Annealed and 1060-CR side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.