FabDigitFabDigit

Steel 1023-A vs 1023-HR

Steel · 1023 temper comparison

1023-A and 1023-HR are two conditions of the same steel grade, 1023: A (solution annealed) versus HR (hot rolled). The chemistry is identical, so every difference below comes from the condition. 1023-A is the stronger of the two: yield strength 285 MPa (41.3 ksi) against 255 MPa (37 ksi) for 1023-HR, about 12% more. 1023-A is the more ductile: elongation 34% versus 25% for 1023-HR, and 1023-HR is harder (123 HB vs 116 HB).

1023-AChoose it when strength drives the design, or when the part is bent, formed or impact-loaded.

1023-A vs 1023-HR: properties

1023-A1023-HR

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

400 MPa58 ksi
425 MPa61.6 ksi

Yield Strength (0.2% offset)

285 MPa41.3 ksi
255 MPa37 ksi

Elongation at Break

34%
25%

Reduction in Area

60%
50%

Shear Strength

320 MPa46.4 ksi
290 MPa42.1 ksi

Fatigue Strength (Endurance Limit)

195 MPa28.3 ksi
205 MPa29.7 ksi

Charpy V-Notch Impact (RT)

70 J51.6 ft·lbf
60 J44.3 ft·lbf

Hardness, Brinell

116 HB
123 HB

Hardness, Rockwell B

66 HRB
71 HRB

Hardness, Vickers

144 HV
129 HV

Same in both: Elastic (Young's) Modulus 200 GPa29 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29 · Compressive Strength 395 MPa57.3 ksi · Fracture Toughness (K_IC) 110 MPa·√m100 ksi·√in

Physical

Density and transition temperatures.

Same in both: Density 7.86 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,425°C2,597 °F · Liquidus Temperature 1,515°C2,759 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 51.9 W/m·K30 BTU/hr·ft·°F · Specific Heat Capacity 486 J/kg·K0.12 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 11.7 µm/m·K6.5 µin/in·°F · Latent Heat of Fusion 247 J/g106 BTU/lb · Max Service Temperature (continuous) 400°C752 °F · Min Service Temperature -30°C-22 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 10.8 % IACS · Electrical Resistivity 1.6×10⁻⁷ Ω·m6.3 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.61 V · Corrosion Resistance 10 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

47 / 100
48 / 100

Formability (cold)

88 / 100
80 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 55% · Weldability 93 / 100 · Castability 40 / 100 · Brazeability / Solderability 80 / 100 · Polishability 55 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 25 MJ/kg10,748 BTU/lb · Embodied Carbon (primary production) 1.9 kg CO₂/kg · Embodied Water 40 L/kg4.8 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale1023

1023-A vs 1023-HR — frequently asked

Is 1023-A stronger than 1023-HR?

Yes. 1023-A has a typical yield strength of 285 MPa (41.3 ksi) against 255 MPa (37 ksi) for 1023-HR — about 12% more. Tensile strength is 400 MPa (58 ksi) vs 425 MPa (61.6 ksi).

Which condition does FabDigit quote by default, A or HR?

CD is the default 1023 condition in the FabDigit quote flow (neither A nor HR). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose 1023-A over 1023-HR?

Pick 1023-A when strength drives the design, or when the part is bent, formed or impact-loaded.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 1023-A and 1023-HR side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.