FabDigitFabDigit

Steel 1020-CD vs 1020-WQT

Steel · 1020 temper comparison

1020-CD and 1020-WQT are two conditions of the same steel grade, 1020: CD (cold drawn) versus WQT (water quenched and tempered). The chemistry is identical, so every difference below comes from the condition. 1020-WQT is the stronger of the two: yield strength 400 MPa (58 ksi) against 350 MPa (50.8 ksi) for 1020-CD, about 14% more; tensile strength follows at 550 MPa (79.8 ksi) vs 420 MPa (60.9 ksi). 1020-WQT is the more ductile: elongation 22% versus 15% for 1020-CD, and 1020-WQT is harder (165 HB vs 121 HB).

1020-WQTChoose it when strength drives the design, or when the part is bent, formed or impact-loaded.

1020-CD vs 1020-WQT: properties

1020-CD1020-WQT

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

420 MPa60.9 ksi
550 MPa79.8 ksi

Yield Strength (0.2% offset)

350 MPa50.8 ksi
400 MPa58 ksi

Elongation at Break

15%
22%

Reduction in Area

40%
55%

Compressive Strength

350 MPa50.8 ksi
400 MPa58 ksi

Shear Strength

310 MPa45 ksi
385 MPa55.8 ksi

Fatigue Strength (Endurance Limit)

230 MPa33.4 ksi
260 MPa37.7 ksi

Fracture Toughness (K_IC)

90 MPa·√m81.9 ksi·√in
105 MPa·√m95.6 ksi·√in

Charpy V-Notch Impact (RT)

45 J33.2 ft·lbf
80 J59 ft·lbf

Hardness, Brinell

121 HB
165 HB

Hardness, Rockwell B

68 HRB
85 HRB

Hardness, Vickers

127 HV
173 HV

Same in both: Elastic (Young's) Modulus 205 GPa29.7 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 140 GPa20.3 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Same in both: Density 7.87 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,495°C2,723 °F · Liquidus Temperature 1,518°C2,764 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

51.9 W/m·K30 BTU/hr·ft·°F
49 W/m·K28.3 BTU/hr·ft·°F

Max Service Temperature (continuous)

425°C797 °F
400°C752 °F

Same in both: Specific Heat Capacity 486 J/kg·K0.12 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 11.7 µm/m·K6.5 µin/in·°F · Latent Heat of Fusion 247 J/g106 BTU/lb · Min Service Temperature -20°C-4 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

10.8 % IACS
10.5 % IACS

Electrical Resistivity

1.6×10⁻⁷ Ω·m6.3 µΩ·in
1.64×10⁻⁷ Ω·m6.46 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.61 V · Corrosion Resistance 10 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

57 / 100
48 / 100

Machinability Rating (AISI 1212 = 100 %)

65%
55%

Weldability

92 / 100
85 / 100

Formability (cold)

70 / 100
55 / 100

Same in both: Castability 45 / 100 · Brazeability / Solderability 80 / 100 · Polishability 45 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 25 MJ/kg10,748 BTU/lb · Embodied Carbon (primary production) 1.9 kg CO₂/kg · Embodied Water 45 L/kg5.4 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale1020

1020-CD vs 1020-WQT — frequently asked

Is 1020-WQT stronger than 1020-CD?

Yes. 1020-WQT has a typical yield strength of 400 MPa (58 ksi) against 350 MPa (50.8 ksi) for 1020-CD — about 14% more. Tensile strength is 550 MPa (79.8 ksi) vs 420 MPa (60.9 ksi).

Which condition does FabDigit quote by default, CD or WQT?

CD is the default 1020 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 1020-CD or 1020-WQT?

1020-CD. Its machinability rates good (57/100) against fair (48/100) for 1020-WQT; for welding the order is 1020-CD first (excellent, 92/100) then 1020-WQT (excellent, 85/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in 1020-CD and 1020-WQT side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.