FabDigitFabDigit

Steel 1020-CD vs 1020-HR

Steel · 1020 temper comparison

1020-CD and 1020-HR are two conditions of the same steel grade, 1020: CD (cold drawn) versus HR (hot rolled). The chemistry is identical, so every difference below comes from the condition. 1020-CD is the stronger of the two: yield strength 350 MPa (50.8 ksi) against 250 MPa (36.3 ksi) for 1020-HR, about 40% more; tensile strength follows at 420 MPa (60.9 ksi) vs 395 MPa (57.3 ksi). In exchange, 1020-HR is the more ductile: elongation 27% versus 15% for 1020-CD, and 1020-CD is harder (121 HB vs 111 HB).

1020-CDChoose it when strength drives the design.

1020-HRChoose it when the part is bent, formed or impact-loaded.

1020-CD vs 1020-HR: properties

1020-CD1020-HR

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

420 MPa60.9 ksi
395 MPa57.3 ksi

Yield Strength (0.2% offset)

350 MPa50.8 ksi
250 MPa36.3 ksi

Elongation at Break

15%
27%

Reduction in Area

40%
50%

Shear Strength

310 MPa45 ksi
290 MPa42.1 ksi

Fatigue Strength (Endurance Limit)

230 MPa33.4 ksi
200 MPa29 ksi

Charpy V-Notch Impact (RT)

45 J33.2 ft·lbf
70 J51.6 ft·lbf

Hardness, Brinell

121 HB
111 HB

Hardness, Rockwell B

68 HRB
62 HRB

Same in both: Elastic (Young's) Modulus 205 GPa29.7 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 140 GPa20.3 Msi · Poisson's Ratio 0.29 · Compressive Strength 350 MPa50.8 ksi · Fracture Toughness (K_IC) 90 MPa·√m81.9 ksi·√in · Hardness, Vickers 127 HV

Physical

Density and transition temperatures.

Same in both: Density 7.87 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,495°C2,723 °F · Liquidus Temperature 1,518°C2,764 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 51.9 W/m·K30 BTU/hr·ft·°F · Specific Heat Capacity 486 J/kg·K0.12 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 11.7 µm/m·K6.5 µin/in·°F · Latent Heat of Fusion 247 J/g106 BTU/lb · Max Service Temperature (continuous) 425°C797 °F · Min Service Temperature -20°C-4 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 10.8 % IACS · Electrical Resistivity 1.6×10⁻⁷ Ω·m6.3 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.61 V · Corrosion Resistance 10 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

57 / 100
54 / 100

Machinability Rating (AISI 1212 = 100 %)

65%
62%

Weldability

92 / 100
95 / 100

Formability (cold)

70 / 100
85 / 100

Same in both: Castability 45 / 100 · Brazeability / Solderability 80 / 100 · Polishability 45 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 25 MJ/kg10,748 BTU/lb · Embodied Carbon (primary production) 1.9 kg CO₂/kg · Embodied Water 45 L/kg5.4 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale1020

1020-CD vs 1020-HR — frequently asked

Is 1020-CD stronger than 1020-HR?

Yes. 1020-CD has a typical yield strength of 350 MPa (50.8 ksi) against 250 MPa (36.3 ksi) for 1020-HR — about 40% more. Tensile strength is 420 MPa (60.9 ksi) vs 395 MPa (57.3 ksi).

Which condition does FabDigit quote by default, CD or HR?

CD is the default 1020 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose 1020-CD over 1020-HR?

Pick 1020-CD when strength drives the design. Pick 1020-HR when the part is bent, formed or impact-loaded.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 1020-CD and 1020-HR side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.