FabDigitFabDigit

Stainless Steel X20Cr13 +C vs X20Cr13 H+T350

Stainless Steel · X20Cr13 temper comparison

X20Cr13 +C and X20Cr13 H+T350 are two conditions of the same stainless steel grade, X20Cr13: +C (cold drawn) versus H+T350 (hardened ~1000 °C, tempered ~350 °C). The chemistry is identical, so every difference below comes from the condition. X20Cr13 H+T350 is the stronger of the two: yield strength 1,200 MPa (174 ksi) against 640 MPa (92.8 ksi) for X20Cr13 +C, about 88% more; tensile strength follows at 1,450 MPa (210 ksi) vs 820 MPa (119 ksi). In exchange, X20Cr13 +C is the more ductile: elongation 12% versus 8% for X20Cr13 H+T350, and X20Cr13 H+T350 is harder (420 HB vs 250 HB). X20Cr13 +C runs hotter in service (400°C vs 300°C continuous). On the shop floor, X20Cr13 +C machines more easily (good vs poor).

X20Cr13 +CChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

X20Cr13 H+T350Choose it when strength drives the design.

X20Cr13 +C vs X20Cr13 H+T350: properties

X20Cr13 +CX20Cr13 H+T350

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

820 MPa119 ksi
1,450 MPa210 ksi

Yield Strength (0.2% offset)

640 MPa92.8 ksi
1,200 MPa174 ksi

Elongation at Break

12%
8%

Reduction in Area

40%
25%

Compressive Strength

650 MPa94.3 ksi
430 MPa62.4 ksi

Shear Strength

500 MPa72.5 ksi
430 MPa62.4 ksi

Fatigue Strength (Endurance Limit)

380 MPa55.1 ksi
560 MPa81.2 ksi

Fracture Toughness (K_IC)

50 MPa·√m45.5 ksi·√in
32 MPa·√m29.1 ksi·√in

Charpy V-Notch Impact (RT)

20 J14.8 ft·lbf
14 J10.3 ft·lbf

Hardness, Brinell

250 HB
420 HB

Hardness, Rockwell B

100 HRB
93 HRB

Hardness, Vickers

263 HV
445 HV

Same in both: Elastic (Young's) Modulus 215 GPa31.2 Msi · Shear Modulus 83 GPa12 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.3

Physical

Density and transition temperatures.

Same in both: Density 7.7 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,450°C2,642 °F · Liquidus Temperature 1,510°C2,750 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

400°C752 °F
300°C572 °F

Same in both: Thermal Conductivity 30 W/m·K17.3 BTU/hr·ft·°F · Specific Heat Capacity 460 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 10.5 µm/m·K5.8 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Min Service Temperature -30°C-22 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 3.1 % IACS · Electrical Resistivity 5.5×10⁻⁷ Ω·m21.7 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

38 / 100
42 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.3 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

58 / 100
28 / 100

Machinability Rating (AISI 1212 = 100 %)

55%
22%

Weldability

25 / 100
30 / 100

Formability (cold)

20 / 100
40 / 100

Polishability

80 / 100
85 / 100

Same in both: Brazeability / Solderability 45 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 55 MJ/kg23,646 BTU/lb · Embodied Carbon (primary production) 4.6 kg CO₂/kg · Embodied Water 130 L/kg15.6 gal/lb · Typical Recycled Content 60%

Strength versus weight

Yield strength against density for every stainless steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

3005007001,0001,5002,0007.27.47.67.888.2Density (g/cm³)Yield strength (MPa) — log scaleX20Cr13

X20Cr13 +C vs X20Cr13 H+T350 — frequently asked

Is X20Cr13 H+T350 stronger than X20Cr13 +C?

Yes. X20Cr13 H+T350 has a typical yield strength of 1,200 MPa (174 ksi) against 640 MPa (92.8 ksi) for X20Cr13 +C — about 88% more. Tensile strength is 1,450 MPa (210 ksi) vs 820 MPa (119 ksi).

Which condition does FabDigit quote by default, +C or H+T350?

+A is the default X20Cr13 condition in the FabDigit quote flow (neither +C nor H+T350). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, X20Cr13 +C or X20Cr13 H+T350?

X20Cr13 +C. Its machinability rates good (58/100) against poor (28/100) for X20Cr13 H+T350; for welding the order is X20Cr13 H+T350 first (poor, 30/100) then X20Cr13 +C (poor, 25/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in X20Cr13 +C and X20Cr13 H+T350 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.