FabDigitFabDigit

Stainless Steel S33550-ANN vs S33550-AW

Stainless Steel · S33550 temper comparison

S33550-ANN and S33550-AW are two conditions of the same stainless steel grade, S33550: ANN (annealed) versus AW (as-welded deposit). The chemistry is identical, so every difference below comes from the condition. S33550-AW is the stronger of the two: yield strength 340 MPa (49.3 ksi) against 310 MPa (45 ksi) for S33550-ANN, about 10% more. In exchange, S33550-ANN is the more ductile: elongation 45% versus 32% for S33550-AW, and S33550-AW is harder (185 HB vs 170 HB).

S33550-ANNChoose it when the part is bent, formed or impact-loaded.

S33550-AWChoose it when strength drives the design.

S33550-ANN vs S33550-AW: properties

S33550-ANNS33550-AW

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

690 MPa100 ksi
650 MPa94.3 ksi

Yield Strength (0.2% offset)

310 MPa45 ksi
340 MPa49.3 ksi

Elongation at Break

45%
32%

Reduction in Area

50%
35%

Compressive Strength

310 MPa45 ksi
340 MPa49.3 ksi

Shear Strength

450 MPa65.3 ksi
430 MPa62.4 ksi

Fatigue Strength (Endurance Limit)

280 MPa40.6 ksi
200 MPa29 ksi

Fracture Toughness (K_IC)

180 MPa·√m164 ksi·√in
140 MPa·√m127 ksi·√in

Charpy V-Notch Impact (RT)

150 J111 ft·lbf
60 J44.3 ft·lbf

Hardness, Brinell

170 HB
185 HB

Hardness, Rockwell B

86 HRB
89 HRB

Hardness, Vickers

180 HV
195 HV

Same in both: Elastic (Young's) Modulus 200 GPa29 Msi · Shear Modulus 77 GPa11.2 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Same in both: Density 8.14 g/cm³0.29 lb/in³ · Melting Point (Solidus) 1,330°C2,426 °F · Liquidus Temperature 1,400°C2,552 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

1,150°C2,102 °F
1,100°C2,012 °F

Same in both: Thermal Conductivity 11.5 W/m·K6.6 BTU/hr·ft·°F · Specific Heat Capacity 460 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 14.4 µm/m·K8 µin/in·°F · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 1.5 % IACS · Electrical Resistivity 1.16×10⁻⁶ Ω·m45.7 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

72 / 100
65 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

25 / 100
22 / 100

Machinability Rating (AISI 1212 = 100 %)

15%
13%

Weldability

75 / 100
72 / 100

Formability (cold)

65 / 100
35 / 100

Same in both: Brazeability / Solderability 60 / 100 · Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 115 MJ/kg49,441 BTU/lb · Embodied Carbon (primary production) 8.5 kg CO₂/kg · Embodied Water 200 L/kg24 gal/lb · Typical Recycled Content 40%

Strength versus weight

Yield strength against density for every stainless steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

3005007001,0001,5002,0007.27.47.67.888.2Density (g/cm³)Yield strength (MPa) — log scaleS33550

S33550-ANN vs S33550-AW — frequently asked

Is S33550-AW stronger than S33550-ANN?

Yes. S33550-AW has a typical yield strength of 340 MPa (49.3 ksi) against 310 MPa (45 ksi) for S33550-ANN — about 10% more. Tensile strength is 650 MPa (94.3 ksi) vs 690 MPa (100 ksi).

Which condition does FabDigit quote by default, ANN or AW?

ANN is the default S33550 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose S33550-ANN over S33550-AW?

Pick S33550-ANN when the part is bent, formed or impact-loaded. Pick S33550-AW when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in S33550-ANN and S33550-AW side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.