FabDigitFabDigit

Stainless Steel S32202 Annealed vs S32202-CD

Stainless Steel · S32202 temper comparison

S32202 Annealed and S32202-CD are two conditions of the same stainless steel grade, S32202: Annealed versus CD (cold drawn). The chemistry is identical, so every difference below comes from the condition. S32202-CD is the stronger of the two: yield strength 680 MPa (98.6 ksi) against 520 MPa (75.4 ksi) for S32202 Annealed, about 31% more; tensile strength follows at 850 MPa (123 ksi) vs 750 MPa (109 ksi). In exchange, S32202 Annealed is the more ductile: elongation 35% versus 20% for S32202-CD, and S32202-CD is harder (290 HB vs 250 HB). S32202 Annealed runs hotter in service (280°C vs 250°C continuous).

S32202 AnnealedChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

S32202-CDChoose it when strength drives the design.

S32202 Annealed vs S32202-CD: properties

S32202 AnnealedS32202-CD

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

750 MPa109 ksi
850 MPa123 ksi

Yield Strength (0.2% offset)

520 MPa75.4 ksi
680 MPa98.6 ksi

Elongation at Break

35%
20%

Reduction in Area

60%
45%

Compressive Strength

530 MPa76.9 ksi
700 MPa102 ksi

Shear Strength

460 MPa66.7 ksi
520 MPa75.4 ksi

Fatigue Strength (Endurance Limit)

420 MPa60.9 ksi
460 MPa66.7 ksi

Fracture Toughness (K_IC)

120 MPa·√m109 ksi·√in
95 MPa·√m86.5 ksi·√in

Charpy V-Notch Impact (RT)

150 J111 ft·lbf
90 J66.4 ft·lbf

Hardness, Brinell

250 HB
290 HB

Hardness, Rockwell C

23 HRC
29 HRC

Hardness, Vickers

260 HV
305 HV

Same in both: Elastic (Young's) Modulus 200 GPa29 Msi · Shear Modulus 77 GPa11.2 Msi · Bulk Modulus 166 GPa24.1 Msi · Poisson's Ratio 0.3 · Hardness, Rockwell B 99 HRB

Physical

Density and transition temperatures.

Same in both: Density 7.7 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,420°C2,588 °F · Liquidus Temperature 1,465°C2,669 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

280°C536 °F
250°C482 °F

Same in both: Thermal Conductivity 15 W/m·K8.7 BTU/hr·ft·°F · Specific Heat Capacity 500 J/kg·K0.12 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 13 µm/m·K7.2 µin/in·°F · Latent Heat of Fusion 265 J/g114 BTU/lb · Min Service Temperature -50°C-58 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 2.2 % IACS · Electrical Resistivity 8×10⁻⁷ Ω·m31.5 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

60 / 100
58 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.15 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

35 / 100
40 / 100

Machinability Rating (AISI 1212 = 100 %)

35%
40%

Weldability

70 / 100
65 / 100

Formability (cold)

55 / 100
35 / 100

Same in both: Castability 40 / 100 · Brazeability / Solderability 35 / 100 · Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 53 MJ/kg22,786 BTU/lb · Embodied Carbon (primary production) 4.5 kg CO₂/kg · Embodied Water 130 L/kg15.6 gal/lb · Typical Recycled Content 70%

Strength versus weight

Yield strength against density for every stainless steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

3005007001,0001,5002,0007.27.47.67.888.2Density (g/cm³)Yield strength (MPa) — log scaleS32202

S32202 Annealed vs S32202-CD — frequently asked

Is S32202-CD stronger than S32202 Annealed?

Yes. S32202-CD has a typical yield strength of 680 MPa (98.6 ksi) against 520 MPa (75.4 ksi) for S32202 Annealed — about 31% more. Tensile strength is 850 MPa (123 ksi) vs 750 MPa (109 ksi).

Which condition does FabDigit quote by default, Annealed or CD?

Annealed is the default S32202 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, S32202 Annealed or S32202-CD?

S32202-CD, by a small margin. Both rate fair for machinability — 40/100 against 35/100 for S32202 Annealed; for welding the order is S32202 Annealed first (very good, 70/100) then S32202-CD (good, 65/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in S32202 Annealed and S32202-CD side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.