Stainless Steel N08700 Annealed vs N08700-CD
Stainless Steel · N08700 temper comparison
N08700 Annealed and N08700-CD are two conditions of the same stainless steel grade, N08700: Annealed versus CD (cold drawn). The chemistry is identical, so every difference below comes from the condition. N08700-CD is the stronger of the two: yield strength 550 MPa (79.8 ksi) against 275 MPa (39.9 ksi) for N08700 Annealed, about 100% more; tensile strength follows at 760 MPa (110 ksi) vs 585 MPa (84.8 ksi). In exchange, N08700 Annealed is the more ductile: elongation 45% versus 25% for N08700-CD, and N08700-CD is harder (215 HB vs 160 HB). N08700 Annealed runs hotter in service (500°C vs 300°C continuous).
N08700 AnnealedChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.
N08700-CDChoose it when strength drives the design.
N08700 Annealed vs N08700-CD: propertiesHow to read these bars
- One bar per material. A full bar is the highest value among all stainless steel grades in the FabDigit library; each bar is drawn as a share of that.
- The better value (by the usual engineering direction) is in bold. Rows with no direction — density, thermal conductivity — have no bold.
- Values are typical room-temperature figures for the condition named on each card.
- Confirm against the certified mill or resin datasheet before design release.
How to read these bars
- One bar per material. A full bar is the highest value among all stainless steel grades in the FabDigit library; each bar is drawn as a share of that.
- The better value (by the usual engineering direction) is in bold. Rows with no direction — density, thermal conductivity — have no bold.
- Values are typical room-temperature figures for the condition named on each card.
- Confirm against the certified mill or resin datasheet before design release.
Mechanical
Strength, stiffness, ductility and hardness at room temperature.
Tensile Strength (Ultimate)
Yield Strength (0.2% offset)
Elongation at Break
Reduction in Area
Shear Strength
Fatigue Strength (Endurance Limit)
Fracture Toughness (K_IC)
Charpy V-Notch Impact (RT)
Hardness, Brinell
Hardness, Rockwell B
Hardness, Vickers
Same in both: Elastic (Young's) Modulus 195 GPa28.3 Msi · Shear Modulus 75 GPa10.9 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.3
Physical
Density and transition temperatures.
Same in both: Density 8 g/cm³0.29 lb/in³ · Melting Point (Solidus) 1,370°C2,498 °F · Liquidus Temperature 1,400°C2,552 °F
Thermal
How each material carries heat and how hot it can run.
Max Service Temperature (continuous)
Same in both: Thermal Conductivity 11.5 W/m·K6.6 BTU/hr·ft·°F · Specific Heat Capacity 460 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 14.8 µm/m·K8.2 µin/in·°F · Latent Heat of Fusion 285 J/g123 BTU/lb · Min Service Temperature -196°C-321 °F
Electrical
Conductivity and insulation.
Same in both: Electrical Conductivity 1.7 % IACS · Electrical Resistivity 1.03×10⁻⁶ Ω·m40.6 µΩ·in
Chemical & Environmental
Corrosion and environmental resistance (0–100 scores).
Corrosion Resistance
Same in both: Galvanic Potential (seawater, vs SCE) -0.12 V
Manufacturability
FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.
Machinability
Machinability Rating (AISI 1212 = 100 %)
Weldability
Formability (cold)
Same in both: Castability 40 / 100 · Brazeability / Solderability 55 / 100 · Polishability 80 / 100
Sustainability
Primary-production footprint per kilogram.
Same in both: Embodied Energy (primary production) 75 MJ/kg32,244 BTU/lb · Embodied Carbon (primary production) 5.5 kg CO₂/kg · Embodied Water 220 L/kg26.4 gal/lb · Typical Recycled Content 40%
Strength versus weight
Yield strength against density for every stainless steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.
N08700 Annealed vs N08700-CD — frequently asked
Is N08700-CD stronger than N08700 Annealed?
Yes. N08700-CD has a typical yield strength of 550 MPa (79.8 ksi) against 275 MPa (39.9 ksi) for N08700 Annealed — about 100% more. Tensile strength is 760 MPa (110 ksi) vs 585 MPa (84.8 ksi).
Which condition does FabDigit quote by default, Annealed or CD?
Annealed is the default N08700 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.
Which welds better, N08700 Annealed or N08700-CD?
N08700 Annealed. Its weldability rates very good (72/100) against good (66/100) for N08700-CD.
Ready to make it?
Upload a CAD file and FabDigit prices the part in N08700 Annealed and N08700-CD side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.
Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.