FabDigitFabDigit

Stainless Steel N08332-CD vs N08332-HF

Stainless Steel · N08332 temper comparison

N08332-CD and N08332-HF are two conditions of the same stainless steel grade, N08332: CD (cold drawn) versus HF (hot Finished bar / forged and annealed). The chemistry is identical, so every difference below comes from the condition. N08332-CD is the stronger of the two: yield strength 550 MPa (79.8 ksi) against 290 MPa (42.1 ksi) for N08332-HF, about 90% more; tensile strength follows at 760 MPa (110 ksi) vs 605 MPa (87.7 ksi). In exchange, N08332-HF is the more ductile: elongation 40% versus 25% for N08332-CD, and N08332-CD is harder (215 HB vs 165 HB). N08332-HF runs hotter in service (1,100°C vs 600°C continuous).

N08332-CDChoose it when strength drives the design.

N08332-HFChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

N08332-CD vs N08332-HF: properties

N08332-CDN08332-HF

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

760 MPa110 ksi
605 MPa87.7 ksi

Yield Strength (0.2% offset)

550 MPa79.8 ksi
290 MPa42.1 ksi

Elongation at Break

25%
40%

Reduction in Area

45%
55%

Compressive Strength

255 MPa37 ksi
295 MPa42.8 ksi

Shear Strength

400 MPa58 ksi
410 MPa59.5 ksi

Fatigue Strength (Endurance Limit)

300 MPa43.5 ksi
250 MPa36.3 ksi

Fracture Toughness (K_IC)

200 MPa·√m182 ksi·√in
185 MPa·√m168 ksi·√in

Charpy V-Notch Impact (RT)

90 J66.4 ft·lbf
140 J103 ft·lbf

Hardness, Brinell

215 HB
165 HB

Hardness, Rockwell B

96 HRB
85 HRB

Hardness, Vickers

158 HV
175 HV

Same in both: Elastic (Young's) Modulus 196 GPa28.4 Msi · Shear Modulus 75 GPa10.9 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Same in both: Density 7.94 g/cm³0.29 lb/in³ · Melting Point (Solidus) 1,345°C2,453 °F · Liquidus Temperature 1,400°C2,552 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

600°C1,112 °F
1,100°C2,012 °F

Same in both: Thermal Conductivity 12.6 W/m·K7.3 BTU/hr·ft·°F · Specific Heat Capacity 460 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 14.4 µm/m·K8 µin/in·°F · Latent Heat of Fusion 285 J/g123 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 1.7 % IACS · Electrical Resistivity 1.02×10⁻⁶ Ω·m40.2 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.15 V · Corrosion Resistance 58 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

30 / 100
32 / 100

Machinability Rating (AISI 1212 = 100 %)

32%
27%

Formability (cold)

45 / 100
64 / 100

Same in both: Weldability 70 / 100 · Castability 55 / 100 · Brazeability / Solderability 60 / 100 · Polishability 65 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 95 MJ/kg40,843 BTU/lb · Embodied Carbon (primary production) 7 kg CO₂/kg · Embodied Water 210 L/kg25.2 gal/lb · Typical Recycled Content 40%

Strength versus weight

Yield strength against density for every stainless steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

3005007001,0001,5002,0007.27.47.67.888.2Density (g/cm³)Yield strength (MPa) — log scaleN08332

N08332-CD vs N08332-HF — frequently asked

Is N08332-CD stronger than N08332-HF?

Yes. N08332-CD has a typical yield strength of 550 MPa (79.8 ksi) against 290 MPa (42.1 ksi) for N08332-HF — about 90% more. Tensile strength is 760 MPa (110 ksi) vs 605 MPa (87.7 ksi).

Which condition does FabDigit quote by default, CD or HF?

Annealed is the default N08332 condition in the FabDigit quote flow (neither CD nor HF). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose N08332-CD over N08332-HF?

Pick N08332-CD when strength drives the design. Pick N08332-HF when the part is bent, formed or impact-loaded, or when the part sees heat.

Ready to make it?

Upload a CAD file and FabDigit prices the part in N08332-CD and N08332-HF side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.