FabDigitFabDigit

Stainless Steel Incoloy 801 Annealed vs Incoloy 801 SolAnn

Stainless Steel · Incoloy 801 temper comparison

Incoloy 801 Annealed and Incoloy 801 SolAnn are two conditions of the same stainless steel grade, Incoloy 801: Annealed versus SolAnn (solution Annealed). The chemistry is identical, so every difference below comes from the condition. Incoloy 801 Annealed is the stronger of the two: yield strength 240 MPa (34.8 ksi) against 215 MPa (31.2 ksi) for Incoloy 801 SolAnn, about 12% more; tensile strength follows at 585 MPa (84.8 ksi) vs 550 MPa (79.8 ksi). Incoloy 801 Annealed is harder — 150 HB against 140 HB for Incoloy 801 SolAnn — which matters for wear surfaces and threads.

Incoloy 801 AnnealedChoose it when strength drives the design, or when surface hardness matters.

Incoloy 801 Annealed vs Incoloy 801 SolAnn: properties

Incoloy 801 AnnealedIncoloy 801 SolAnn

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

585 MPa84.8 ksi
550 MPa79.8 ksi

Yield Strength (0.2% offset)

240 MPa34.8 ksi
215 MPa31.2 ksi

Elongation at Break

42%
45%

Reduction in Area

55%
60%

Shear Strength

400 MPa58 ksi
380 MPa55.1 ksi

Fatigue Strength (Endurance Limit)

250 MPa36.3 ksi
235 MPa34.1 ksi

Charpy V-Notch Impact (RT)

150 J111 ft·lbf
175 J129 ft·lbf

Hardness, Brinell

150 HB
140 HB

Hardness, Rockwell B

80 HRB
75 HRB

Same in both: Elastic (Young's) Modulus 196 GPa28.4 Msi · Shear Modulus 76 GPa11 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.31

Physical

Density and transition temperatures.

Same in both: Density 7.94 g/cm³0.29 lb/in³ · Melting Point (Solidus) 1,355°C2,471 °F · Liquidus Temperature 1,385°C2,525 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

815°C1,499 °F
870°C1,598 °F

Same in both: Thermal Conductivity 11.5 W/m·K6.6 BTU/hr·ft·°F · Specific Heat Capacity 460 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 14.4 µm/m·K8 µin/in·°F · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 1.7 % IACS · Electrical Resistivity 1×10⁻⁶ Ω·m39.4 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

66 / 100
67 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.15 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

30 / 100
32 / 100

Machinability Rating (AISI 1212 = 100 %)

30%
32%

Weldability

70 / 100
72 / 100

Formability (cold)

70 / 100
72 / 100

Same in both: Castability 35 / 100 · Brazeability / Solderability 65 / 100 · Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 110 MJ/kg47,292 BTU/lb · Embodied Carbon (primary production) 8 kg CO₂/kg · Embodied Water 220 L/kg26.4 gal/lb · Typical Recycled Content 45%

Strength versus weight

Yield strength against density for every stainless steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

3005007001,0001,5002,0007.27.47.67.888.2Density (g/cm³)Yield strength (MPa) — log scaleIncoloy 801

Incoloy 801 Annealed vs Incoloy 801 SolAnn — frequently asked

Is Incoloy 801 Annealed stronger than Incoloy 801 SolAnn?

Yes. Incoloy 801 Annealed has a typical yield strength of 240 MPa (34.8 ksi) against 215 MPa (31.2 ksi) for Incoloy 801 SolAnn — about 12% more. Tensile strength is 585 MPa (84.8 ksi) vs 550 MPa (79.8 ksi).

Which condition does FabDigit quote by default, Annealed or SolAnn?

Annealed is the default Incoloy 801 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose Incoloy 801 Annealed over Incoloy 801 SolAnn?

Pick Incoloy 801 Annealed when strength drives the design, or when surface hardness matters.

Ready to make it?

Upload a CAD file and FabDigit prices the part in Incoloy 801 Annealed and Incoloy 801 SolAnn side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.