FabDigitFabDigit

Stainless Steel Discaloy-CD vs Discaloy-STA

Stainless Steel · Discaloy temper comparison

Discaloy-CD and Discaloy-STA are two conditions of the same stainless steel grade, Discaloy: CD (cold drawn) versus STA (solution treated and aged). The chemistry is identical, so every difference below comes from the condition. Discaloy-CD is the stronger of the two: yield strength 950 MPa (138 ksi) against 730 MPa (106 ksi) for Discaloy-STA, about 30% more; tensile strength follows at 1,150 MPa (167 ksi) vs 1,000 MPa (145 ksi). In exchange, Discaloy-STA is the more ductile: elongation 20% versus 12% for Discaloy-CD, and Discaloy-CD is harder (330 HB vs 290 HB). Discaloy-STA runs hotter in service (650°C vs 540°C continuous).

Discaloy-CDChoose it when strength drives the design.

Discaloy-STAChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

Discaloy-CD vs Discaloy-STA: properties

Discaloy-CDDiscaloy-STA

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

1,150 MPa167 ksi
1,000 MPa145 ksi

Yield Strength (0.2% offset)

950 MPa138 ksi
730 MPa106 ksi

Elongation at Break

12%
20%

Reduction in Area

25%
30%

Shear Strength

700 MPa102 ksi
640 MPa92.8 ksi

Fatigue Strength (Endurance Limit)

430 MPa62.4 ksi
380 MPa55.1 ksi

Charpy V-Notch Impact (RT)

25 J18.4 ft·lbf
35 J25.8 ft·lbf

Hardness, Brinell

330 HB
290 HB

Hardness, Rockwell C

35 HRC
30 HRC

Hardness, Vickers

350 HV
305 HV

Same in both: Elastic (Young's) Modulus 196 GPa28.4 Msi · Shear Modulus 76 GPa11 Msi · Bulk Modulus 165 GPa23.9 Msi · Poisson's Ratio 0.3

Physical

Density and transition temperatures.

Same in both: Density 7.97 g/cm³0.29 lb/in³ · Melting Point (Solidus) 1,380°C2,516 °F · Liquidus Temperature 1,430°C2,606 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

540°C1,004 °F
650°C1,202 °F

Same in both: Thermal Conductivity 14 W/m·K8.1 BTU/hr·ft·°F · Specific Heat Capacity 460 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 15.5 µm/m·K8.6 µin/in·°F · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Resistivity

9.2×10⁻⁷ Ω·m36.2 µΩ·in
9.1×10⁻⁷ Ω·m35.8 µΩ·in

Same in both: Electrical Conductivity 1.9 % IACS

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

60 / 100
62 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

16 / 100
18 / 100

Machinability Rating (AISI 1212 = 100 %)

12%
14%

Weldability

30 / 100
35 / 100

Formability (cold)

15 / 100
25 / 100

Same in both: Castability 35 / 100 · Brazeability / Solderability 45 / 100 · Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 80 MJ/kg34,394 BTU/lb · Embodied Carbon (primary production) 5.5 kg CO₂/kg · Embodied Water 190 L/kg22.8 gal/lb · Typical Recycled Content 35%

Strength versus weight

Yield strength against density for every stainless steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

3005007001,0001,5002,0007.27.47.67.888.2Density (g/cm³)Yield strength (MPa) — log scaleDiscaloy

Discaloy-CD vs Discaloy-STA — frequently asked

Is Discaloy-CD stronger than Discaloy-STA?

Yes. Discaloy-CD has a typical yield strength of 950 MPa (138 ksi) against 730 MPa (106 ksi) for Discaloy-STA — about 30% more. Tensile strength is 1,150 MPa (167 ksi) vs 1,000 MPa (145 ksi).

Which condition does FabDigit quote by default, CD or STA?

STA is the default Discaloy condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which welds better, Discaloy-CD or Discaloy-STA?

Discaloy-STA. Its weldability rates fair (35/100) against poor (30/100) for Discaloy-CD.

Ready to make it?

Upload a CAD file and FabDigit prices the part in Discaloy-CD and Discaloy-STA side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.