FabDigitFabDigit

Stainless Steel CX Hardened & Tempered vs CX-HIP

Stainless Steel · CX temper comparison

CX Hardened & Tempered and CX-HIP are two conditions of the same stainless steel grade, CX: Hardened & Tempered (quenched and tempered) versus HIP (hot isostatic pressed). The chemistry is identical, so every difference below comes from the condition. CX Hardened & Tempered is the stronger of the two: yield strength 1,550 MPa (225 ksi) against 790 MPa (115 ksi) for CX-HIP, about 96% more; tensile strength follows at 1,670 MPa (242 ksi) vs 1,030 MPa (149 ksi). In exchange, CX-HIP is the more ductile: elongation 16% versus 5% for CX Hardened & Tempered, and CX Hardened & Tempered is harder (50 HRC vs 34 HRC). CX Hardened & Tempered is stiffer (200 GPa vs 190 GPa) and CX Hardened & Tempered runs hotter in service (400°C vs 350°C continuous). On the shop floor, CX-HIP machines more easily (fair vs poor).

CX Hardened & TemperedChoose it when strength drives the design, or when the part sees heat.

CX-HIPChoose it when the part is bent, formed or impact-loaded, or when the part is machined in volume.

CX Hardened & Tempered vs CX-HIP: properties

CX Hardened & TemperedCX-HIP

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

200 GPa29 Msi
190 GPa27.6 Msi

Tensile Strength (Ultimate)

1,670 MPa242 ksi
1,030 MPa149 ksi

Yield Strength (0.2% offset)

1,550 MPa225 ksi
790 MPa115 ksi

Elongation at Break

5%
16%

Reduction in Area

20%
48%

Compressive Strength

1,650 MPa239 ksi
860 MPa125 ksi

Shear Strength

1,000 MPa145 ksi
620 MPa89.9 ksi

Fatigue Strength (Endurance Limit)

650 MPa94.3 ksi
480 MPa69.6 ksi

Fracture Toughness (K_IC)

55 MPa·√m50.1 ksi·√in
95 MPa·√m86.5 ksi·√in

Charpy V-Notch Impact (RT)

12 J8.9 ft·lbf
35 J25.8 ft·lbf

Hardness, Brinell

310 HB
320 HB

Hardness, Rockwell C

50 HRC
34 HRC

Hardness, Vickers

545 HV
340 HV

Same in both: Shear Modulus 72 GPa10.4 Msi · Bulk Modulus 155 GPa22.5 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Same in both: Density 7.7 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,400°C2,552 °F · Liquidus Temperature 1,450°C2,642 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

400°C752 °F
350°C662 °F

Same in both: Thermal Conductivity 18 W/m·K10.4 BTU/hr·ft·°F · Specific Heat Capacity 430 J/kg·K0.1 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 10.8 µm/m·K6 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Min Service Temperature -60°C-76 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 2.2 % IACS · Electrical Resistivity 8×10⁻⁷ Ω·m31.5 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

58 / 100
60 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.25 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

22 / 100
42 / 100

Machinability Rating (AISI 1212 = 100 %)

20%
45%

Weldability

70 / 100
72 / 100

Formability (cold)

25 / 100
32 / 100

Polishability

90 / 100
85 / 100

Same in both: Castability 45 / 100 · Brazeability / Solderability 55 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 78 MJ/kg33,534 BTU/lb · Embodied Carbon (primary production) 6.8 kg CO₂/kg · Embodied Water 110 L/kg13.2 gal/lb · Typical Recycled Content 25%

Strength versus weight

Yield strength against density for every stainless steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

3005007001,0001,5002,0007.27.47.67.888.2Density (g/cm³)Yield strength (MPa) — log scaleCX

CX Hardened & Tempered vs CX-HIP — frequently asked

Is CX Hardened & Tempered stronger than CX-HIP?

Yes. CX Hardened & Tempered has a typical yield strength of 1,550 MPa (225 ksi) against 790 MPa (115 ksi) for CX-HIP — about 96% more. Tensile strength is 1,670 MPa (242 ksi) vs 1,030 MPa (149 ksi).

Which condition does FabDigit quote by default, Hardened & Tempered or HIP?

As Printed is the default CX condition in the FabDigit quote flow (neither Hardened & Tempered nor HIP). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, CX Hardened & Tempered or CX-HIP?

CX-HIP. Its machinability rates fair (42/100) against poor (22/100) for CX Hardened & Tempered.

Ready to make it?

Upload a CAD file and FabDigit prices the part in CX Hardened & Tempered and CX-HIP side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.