Stainless Steel CB7Cu-1 vs CD4MCuN
Stainless Steel · grade comparison
Stainless Steel CB7Cu-1 and CD4MCuN are both stainless steel grades. CB7Cu-1 is the stronger of the two: yield strength 790 MPa (115 ksi) against 550 MPa (79.8 ksi) for CD4MCuN, about 44% more; tensile strength follows at 895 MPa (130 ksi) vs 730 MPa (106 ksi). In exchange, CD4MCuN is the more ductile: elongation 25% versus 14% for CB7Cu-1, and CB7Cu-1 is harder (270 HB vs 250 HB). CB7Cu-1 conducts heat better (18.3 W/m·K vs 16 W/m·K). On the shop floor, CB7Cu-1 machines more easily (fair vs poor).
CB7Cu-1Choose it when strength drives the design, or when the part is machined in volume.
CD4MCuNChoose it when the part is bent, formed or impact-loaded.
CB7Cu-1 vs CD4MCuN: propertiesHow to read these bars
- One bar per material. A full bar is the highest value among all stainless steel grades in the FabDigit library; each bar is drawn as a share of that.
- The better value (by the usual engineering direction) is in bold. Rows with no direction — density, thermal conductivity — have no bold.
- Values are typical room-temperature figures for the condition named on each card.
- Confirm against the certified mill or resin datasheet before design release.
How to read these bars
- One bar per material. A full bar is the highest value among all stainless steel grades in the FabDigit library; each bar is drawn as a share of that.
- The better value (by the usual engineering direction) is in bold. Rows with no direction — density, thermal conductivity — have no bold.
- Values are typical room-temperature figures for the condition named on each card.
- Confirm against the certified mill or resin datasheet before design release.
Mechanical
Strength, stiffness, ductility and hardness at room temperature.
Elastic (Young's) Modulus
Bulk Modulus
Poisson's Ratio
Tensile Strength (Ultimate)
Yield Strength (0.2% offset)
Elongation at Break
Compressive Strength
Shear Strength
Fatigue Strength (Endurance Limit)
Fracture Toughness (K_IC)
Charpy V-Notch Impact (RT)
Hardness, Brinell
Hardness, Rockwell C
Hardness, Vickers
Same in both: Shear Modulus 77 GPa11.2 Msi · Reduction in Area 40%
Physical
Density and transition temperatures.
Melting Point (Solidus)
Liquidus Temperature
Same in both: Density 7.75 g/cm³0.28 lb/in³
Thermal
How each material carries heat and how hot it can run.
Thermal Conductivity
Specific Heat Capacity
Thermal Expansion (CTE, 20–100 °C)
Max Service Temperature (continuous)
Min Service Temperature
Same in both: Latent Heat of Fusion 270 J/g116 BTU/lb
Electrical
Conductivity and insulation.
Same in both: Electrical Conductivity 2.2 % IACS · Electrical Resistivity 8×10⁻⁷ Ω·m31.5 µΩ·in
Chemical & Environmental
Corrosion and environmental resistance (0–100 scores).
Galvanic Potential (seawater, vs SCE)
Corrosion Resistance
Manufacturability
FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.
Machinability
Machinability Rating (AISI 1212 = 100 %)
Weldability
Formability (cold)
Castability
Brazeability / Solderability
Polishability
Sustainability
Primary-production footprint per kilogram.
Embodied Energy (primary production)
Embodied Carbon (primary production)
Embodied Water
Typical Recycled Content
Common Calculations
Ratios derived from the values above.
Specific Strength (UTS / density)
Specific Stiffness (E / density)
Modulus of Resilience
Thermal Diffusivity
Thermal Shock Resistance Index
Strength versus weight
Yield strength against density for every stainless steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.
Manufacturing and finishing
| Capability | CB7Cu-1 | CD4MCuN |
|---|---|---|
| Default condition | — | — |
| Relative cost | $$$ Premium | $$$ Premium |
| Min. machined wall | — | — |
| Best machined surface | — | — |
Both take the same 7 finishes: Electroless Nickel (EN), Epoxy Coating, Gold Plating, Hard Chrome Plating, Pickling, Plasma Spray, Silver Plating.
CB7Cu-1 vs CD4MCuN — frequently asked
Is CB7Cu-1 stronger than CD4MCuN?
Yes. CB7Cu-1 has a typical yield strength of 790 MPa (115 ksi) against 550 MPa (79.8 ksi) for CD4MCuN — about 44% more. Tensile strength is 895 MPa (130 ksi) vs 730 MPa (106 ksi).
Which is cheaper, CB7Cu-1 or CD4MCuN?
Both sit in the same relative cost tier ($$$, premium); the part price will be decided by machining time, tolerance and quantity rather than by the material.
Which is easier to machine, CB7Cu-1 or CD4MCuN?
CB7Cu-1. Its machinability rates fair (45/100) against poor (30/100) for CD4MCuN; for welding the order is CB7Cu-1 first (good, 60/100) then CD4MCuN (good, 55/100).
Ready to make it?
Upload a CAD file and FabDigit prices the part in CB7Cu-1 and CD4MCuN side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.
Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.