FabDigitFabDigit

Stainless Steel CB30 vs CC50

Stainless Steel · grade comparison

Stainless Steel CB30 and CC50 are both stainless steel grades. CB30 is the stronger of the two: yield strength 415 MPa (60.2 ksi) against 275 MPa (39.9 ksi) for CC50, about 51% more; tensile strength follows at 655 MPa (95 ksi) vs 480 MPa (69.6 ksi). CB30 is the more ductile: elongation 15% versus 10% for CC50, and CC50 is harder (210 HB vs 195 HB). CC50 runs hotter in service (1,090°C vs 400°C continuous) and CB30 conducts heat better (23 W/m·K vs 20.5 W/m·K).

CB30Choose it when strength drives the design, or when the part is bent, formed or impact-loaded.

CC50Choose it when the part sees heat.

CB30 vs CC50: properties

CB30CC50

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Bulk Modulus

152 GPa22 Msi
160 GPa23.2 Msi

Tensile Strength (Ultimate)

655 MPa95 ksi
480 MPa69.6 ksi

Yield Strength (0.2% offset)

415 MPa60.2 ksi
275 MPa39.9 ksi

Elongation at Break

15%
10%

Reduction in Area

25%
12%

Compressive Strength

420 MPa60.9 ksi
290 MPa42.1 ksi

Shear Strength

430 MPa62.4 ksi
300 MPa43.5 ksi

Fatigue Strength (Endurance Limit)

250 MPa36.3 ksi
175 MPa25.4 ksi

Fracture Toughness (K_IC)

45 MPa·√m41 ksi·√in
40 MPa·√m36.4 ksi·√in

Charpy V-Notch Impact (RT)

3 J2.2 ft·lbf
8 J5.9 ft·lbf

Hardness, Brinell

195 HB
210 HB

Hardness, Rockwell B

92 HRB
95 HRB

Hardness, Rockwell C

13 HRC
—

Hardness, Vickers

205 HV
220 HV

Same in both: Elastic (Young's) Modulus 200 GPa29 Msi · Shear Modulus 77 GPa11.2 Msi · Poisson's Ratio 0.28

Physical

Density and transition temperatures.

Density

7.53 g/cm³0.27 lb/in³
7.6 g/cm³0.27 lb/in³

Melting Point (Solidus)

1,425°C2,597 °F
1,370°C2,498 °F

Liquidus Temperature

1,505°C2,741 °F
1,450°C2,642 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

23 W/m·K13.3 BTU/hr·ft·°F
20.5 W/m·K11.8 BTU/hr·ft·°F

Specific Heat Capacity

460 J/kg·K0.11 BTU/lb·°F
500 J/kg·K0.12 BTU/lb·°F

Thermal Expansion (CTE, 20–100 °C)

10.4 µm/m·K5.8 µin/in·°F
10.5 µm/m·K5.8 µin/in·°F

Max Service Temperature (continuous)

400°C752 °F
1,090°C1,994 °F

Min Service Temperature

0°C32 °F
-20°C-4 °F

Same in both: Latent Heat of Fusion 270 J/g116 BTU/lb

Electrical

Conductivity and insulation.

Electrical Conductivity

2.5 % IACS
2.3 % IACS

Electrical Resistivity

7×10⁻⁷ Ω·m27.6 µΩ·in
7.5×10⁻⁷ Ω·m29.5 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Galvanic Potential (seawater, vs SCE)

-0.2 V
-0.25 V

Corrosion Resistance

55 / 100
72 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

42 / 100
35 / 100

Machinability Rating (AISI 1212 = 100 %)

45%
40%

Brazeability / Solderability

40 / 100
45 / 100

Same in both: Weldability 30 / 100 · Formability (cold) 10 / 100 · Castability 65 / 100 · Polishability 55 / 100

Sustainability

Primary-production footprint per kilogram.

Embodied Energy (primary production)

53 MJ/kg22,786 BTU/lb
55 MJ/kg23,646 BTU/lb

Embodied Carbon (primary production)

3.6 kg CO₂/kg
4.2 kg CO₂/kg

Embodied Water

120 L/kg14.4 gal/lb
110 L/kg13.2 gal/lb

Typical Recycled Content

75%
65%

Common Calculations

Ratios derived from the values above.

Specific Strength (UTS / density)

87 kN·m/kg
63 kN·m/kg

Specific Stiffness (E / density)

26.6 MN·m/kg
26.3 MN·m/kg

Modulus of Resilience

431 kJ/m³
189 kJ/m³

Thermal Diffusivity

6.6 mm²/s
5.4 mm²/s

Thermal Shock Resistance Index

7
5

Strength versus weight

Yield strength against density for every stainless steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

3005007001,0001,5002,0007.27.47.67.888.2Density (g/cm³)Yield strength (MPa) — log scaleCB30CC50

Manufacturing and finishing

CapabilityCB30CC50
Default condition——
Relative cost$$$ Premium$$$ Premium
Min. machined wall——
Best machined surface——

Both take the same 7 finishes: Electroless Nickel (EN), Epoxy Coating, Gold Plating, Hard Chrome Plating, Pickling, Plasma Spray, Silver Plating.

CB30 vs CC50 — frequently asked

Is CB30 stronger than CC50?

Yes. CB30 has a typical yield strength of 415 MPa (60.2 ksi) against 275 MPa (39.9 ksi) for CC50 — about 51% more. Tensile strength is 655 MPa (95 ksi) vs 480 MPa (69.6 ksi).

Which is cheaper, CB30 or CC50?

Both sit in the same relative cost tier ($$$, premium); the part price will be decided by machining time, tolerance and quantity rather than by the material.

Which is easier to machine, CB30 or CC50?

CB30, by a small margin. Both rate fair for machinability — 42/100 against 35/100 for CC50.

Ready to make it?

Upload a CAD file and FabDigit prices the part in CB30 and CC50 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.