FabDigitFabDigit

Stainless Steel 347H Cold Drawn vs 347H Stabilize Annealed

Stainless Steel · 347H temper comparison

347H Cold Drawn and 347H Stabilize Annealed are two conditions of the same stainless steel grade, 347H: Cold Drawn versus Stabilize Annealed (885–950 °C hold after solution anneal or welding). The chemistry is identical, so every difference below comes from the condition. 347H Cold Drawn is the stronger of the two: yield strength 520 MPa (75.4 ksi) against 280 MPa (40.6 ksi) for 347H Stabilize Annealed, about 86% more; tensile strength follows at 790 MPa (115 ksi) vs 615 MPa (89.2 ksi). In exchange, 347H Stabilize Annealed is the more ductile: elongation 43% versus 28% for 347H Cold Drawn, and 347H Cold Drawn is harder (225 HB vs 165 HB).

347H Cold DrawnChoose it when strength drives the design.

347H Stabilize AnnealedChoose it when the part is bent, formed or impact-loaded.

347H Cold Drawn vs 347H Stabilize Annealed: properties

347H Cold Drawn347H Stabilize Annealed

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

790 MPa115 ksi
615 MPa89.2 ksi

Yield Strength (0.2% offset)

520 MPa75.4 ksi
280 MPa40.6 ksi

Elongation at Break

28%
43%

Reduction in Area

45%
58%

Compressive Strength

275 MPa39.9 ksi
285 MPa41.3 ksi

Fatigue Strength (Endurance Limit)

310 MPa45 ksi
240 MPa34.8 ksi

Charpy V-Notch Impact (RT)

90 J66.4 ft·lbf
140 J103 ft·lbf

Hardness, Brinell

225 HB
165 HB

Hardness, Rockwell B

97 HRB
85 HRB

Same in both: Elastic (Young's) Modulus 195 GPa28.3 Msi · Shear Modulus 77 GPa11.2 Msi · Bulk Modulus 158 GPa22.9 Msi · Poisson's Ratio 0.3 · Shear Strength 400 MPa58 ksi · Fracture Toughness (K_IC) 200 MPa·√m182 ksi·√in

Physical

Density and transition temperatures.

Same in both: Density 7.96 g/cm³0.29 lb/in³ · Melting Point (Solidus) 1,400°C2,552 °F · Liquidus Temperature 1,450°C2,642 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 16.1 W/m·K9.3 BTU/hr·ft·°F · Specific Heat Capacity 500 J/kg·K0.12 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 16.6 µm/m·K9.2 µin/in·°F · Latent Heat of Fusion 285 J/g123 BTU/lb · Max Service Temperature (continuous) 815°C1,499 °F · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 2.4 % IACS · Electrical Resistivity 7.3×10⁻⁷ Ω·m28.7 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

57 / 100
60 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.1 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

40 / 100
33 / 100

Machinability Rating (AISI 1212 = 100 %)

45%
38%

Weldability

78 / 100
80 / 100

Formability (cold)

40 / 100
65 / 100

Same in both: Castability 45 / 100 · Brazeability / Solderability 65 / 100 · Polishability 75 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 60 MJ/kg25,795 BTU/lb · Embodied Carbon (primary production) 5.3 kg CO₂/kg · Embodied Water 165 L/kg19.8 gal/lb · Typical Recycled Content 60%

Strength versus weight

Yield strength against density for every stainless steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

3005007001,0001,5002,0007.27.47.67.888.2Density (g/cm³)Yield strength (MPa) — log scale347H

347H Cold Drawn vs 347H Stabilize Annealed — frequently asked

Is 347H Cold Drawn stronger than 347H Stabilize Annealed?

Yes. 347H Cold Drawn has a typical yield strength of 520 MPa (75.4 ksi) against 280 MPa (40.6 ksi) for 347H Stabilize Annealed — about 86% more. Tensile strength is 790 MPa (115 ksi) vs 615 MPa (89.2 ksi).

Which condition does FabDigit quote by default, Cold Drawn or Stabilize Annealed?

Solution Annealed is the default 347H condition in the FabDigit quote flow (neither Cold Drawn nor Stabilize Annealed). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 347H Cold Drawn or 347H Stabilize Annealed?

347H Cold Drawn. Its machinability rates fair (40/100) against poor (33/100) for 347H Stabilize Annealed.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 347H Cold Drawn and 347H Stabilize Annealed side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.