FabDigitFabDigit

Stainless Steel 347H Annealed vs 347H Cold Drawn

Stainless Steel · 347H temper comparison

347H Annealed and 347H Cold Drawn are two conditions of the same stainless steel grade, 347H: Annealed versus Cold Drawn. The chemistry is identical, so every difference below comes from the condition. 347H Cold Drawn is the stronger of the two: yield strength 520 MPa (75.4 ksi) against 255 MPa (37 ksi) for 347H Annealed, about 104% more; tensile strength follows at 790 MPa (115 ksi) vs 600 MPa (87 ksi). In exchange, 347H Annealed is the more ductile: elongation 50% versus 28% for 347H Cold Drawn, and 347H Cold Drawn is harder (225 HB vs 150 HB).

347H AnnealedChoose it when the part is bent, formed or impact-loaded.

347H Cold DrawnChoose it when strength drives the design.

347H Annealed vs 347H Cold Drawn: properties

347H Annealed347H Cold Drawn

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

600 MPa87 ksi
790 MPa115 ksi

Yield Strength (0.2% offset)

255 MPa37 ksi
520 MPa75.4 ksi

Elongation at Break

50%
28%

Reduction in Area

62%
45%

Compressive Strength

255 MPa37 ksi
275 MPa39.9 ksi

Shear Strength

390 MPa56.6 ksi
400 MPa58 ksi

Fatigue Strength (Endurance Limit)

235 MPa34.1 ksi
310 MPa45 ksi

Charpy V-Notch Impact (RT)

160 J118 ft·lbf
90 J66.4 ft·lbf

Hardness, Brinell

150 HB
225 HB

Hardness, Rockwell B

80 HRB
97 HRB

Same in both: Elastic (Young's) Modulus 195 GPa28.3 Msi · Shear Modulus 77 GPa11.2 Msi · Bulk Modulus 158 GPa22.9 Msi · Poisson's Ratio 0.3 · Fracture Toughness (K_IC) 200 MPa·√m182 ksi·√in

Physical

Density and transition temperatures.

Same in both: Density 7.96 g/cm³0.29 lb/in³ · Melting Point (Solidus) 1,400°C2,552 °F · Liquidus Temperature 1,450°C2,642 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 16.1 W/m·K9.3 BTU/hr·ft·°F · Specific Heat Capacity 500 J/kg·K0.12 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 16.6 µm/m·K9.2 µin/in·°F · Latent Heat of Fusion 285 J/g123 BTU/lb · Max Service Temperature (continuous) 815°C1,499 °F · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 2.4 % IACS · Electrical Resistivity 7.3×10⁻⁷ Ω·m28.7 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.1 V · Corrosion Resistance 57 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

37 / 100
40 / 100

Machinability Rating (AISI 1212 = 100 %)

42%
45%

Weldability

80 / 100
78 / 100

Formability (cold)

70 / 100
40 / 100

Same in both: Castability 45 / 100 · Brazeability / Solderability 65 / 100 · Polishability 75 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 60 MJ/kg25,795 BTU/lb · Embodied Carbon (primary production) 5.3 kg CO₂/kg · Embodied Water 165 L/kg19.8 gal/lb · Typical Recycled Content 60%

Strength versus weight

Yield strength against density for every stainless steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

3005007001,0001,5002,0007.27.47.67.888.2Density (g/cm³)Yield strength (MPa) — log scale347H

347H Annealed vs 347H Cold Drawn — frequently asked

Is 347H Cold Drawn stronger than 347H Annealed?

Yes. 347H Cold Drawn has a typical yield strength of 520 MPa (75.4 ksi) against 255 MPa (37 ksi) for 347H Annealed — about 104% more. Tensile strength is 790 MPa (115 ksi) vs 600 MPa (87 ksi).

Which condition does FabDigit quote by default, Annealed or Cold Drawn?

Solution Annealed is the default 347H condition in the FabDigit quote flow (neither Annealed nor Cold Drawn). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose 347H Annealed over 347H Cold Drawn?

Pick 347H Annealed when the part is bent, formed or impact-loaded. Pick 347H Cold Drawn when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 347H Annealed and 347H Cold Drawn side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.