Stainless Steel 314 Cold Drawn vs 314 Solution Annealed

Stainless Steel · 314 temper comparison

314 Cold Drawn and 314 Solution Annealed are two conditions of the same stainless steel grade, 314: Cold Drawn versus Solution Annealed. The chemistry is identical, so every difference below comes from the condition. 314 Cold Drawn is the stronger of the two: yield strength 550 MPa (79.8 ksi) against 345 MPa (50 ksi) for 314 Solution Annealed, about 59% more; tensile strength follows at 810 MPa (117 ksi) vs 690 MPa (100 ksi). In exchange, 314 Solution Annealed is the more ductile: elongation 40% versus 25% for 314 Cold Drawn, and 314 Cold Drawn is harder (235 HB vs 180 HB).

314 Cold DrawnChoose it when strength drives the design.

314 Solution AnnealedChoose it when the part is bent, formed or impact-loaded.

314 Cold Drawn vs 314 Solution Annealed: properties

314 Cold Drawn314 Solution Annealed

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

810 MPa117 ksi
690 MPa100 ksi

Yield Strength (0.2% offset)

550 MPa79.8 ksi
345 MPa50 ksi

Elongation at Break

25%
40%

Reduction in Area

45%
50%

Shear Strength

500 MPa72.5 ksi
450 MPa65.3 ksi

Fatigue Strength (Endurance Limit)

300 MPa43.5 ksi
250 MPa36.3 ksi

Charpy V-Notch Impact (RT)

55 J40.6 ft·lbf
80 J59 ft·lbf

Hardness, Brinell

235 HB
180 HB

Hardness, Rockwell B

98 HRB
87 HRB

Hardness, Vickers

247 HV
190 HV

Same in both: Elastic (Young's) Modulus 200 GPa29 Msi · Shear Modulus 77 GPa11.2 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Same in both: Density 7.72 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,400°C2,552 °F · Liquidus Temperature 1,425°C2,597 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 17 W/m·K9.8 BTU/hr·ft·°F · Specific Heat Capacity 500 J/kg·K0.12 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 15 µm/m·K8.3 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Max Service Temperature (continuous) 1,100°C2,012 °F · Min Service Temperature -100°C-148 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 2 % IACS · Electrical Resistivity 8.5×10⁻⁷ Ω·m33.5 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

66 / 100
68 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.05 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

32 / 100
28 / 100

Machinability Rating (AISI 1212 = 100 %)

35%
30%

Weldability

42 / 100
45 / 100

Formability (cold)

35 / 100
55 / 100

Same in both: Brazeability / Solderability 50 / 100 · Polishability 55 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 82 MJ/kg35,254 BTU/lb · Embodied Carbon (primary production) 5.8 kg CO₂/kg · Embodied Water 150 L/kg18 gal/lb · Typical Recycled Content 55%

Strength versus weight

Yield strength against density for every stainless steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

3005007001,0001,5002,0007.27.47.67.888.2Density (g/cm³)Yield strength (MPa) — log scale314

314 Cold Drawn vs 314 Solution Annealed — frequently asked

Is 314 Cold Drawn stronger than 314 Solution Annealed?

Yes. 314 Cold Drawn has a typical yield strength of 550 MPa (79.8 ksi) against 345 MPa (50 ksi) for 314 Solution Annealed — about 59% more. Tensile strength is 810 MPa (117 ksi) vs 690 MPa (100 ksi).

Which condition does FabDigit quote by default, Cold Drawn or Solution Annealed?

Solution Annealed is the default 314 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose 314 Cold Drawn over 314 Solution Annealed?

Pick 314 Cold Drawn when strength drives the design. Pick 314 Solution Annealed when the part is bent, formed or impact-loaded.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 314 Cold Drawn and 314 Solution Annealed side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.