FabDigitFabDigit

Stainless Steel 310S Cold Drawn vs 310S Solution Annealed

Stainless Steel · 310S temper comparison

310S Cold Drawn and 310S Solution Annealed are two conditions of the same stainless steel grade, 310S: Cold Drawn versus Solution Annealed. The chemistry is identical, so every difference below comes from the condition. 310S Cold Drawn is the stronger of the two: yield strength 520 MPa (75.4 ksi) against 260 MPa (37.7 ksi) for 310S Solution Annealed, about 100% more; tensile strength follows at 760 MPa (110 ksi) vs 590 MPa (85.6 ksi). In exchange, 310S Solution Annealed is the more ductile: elongation 45% versus 25% for 310S Cold Drawn, and 310S Cold Drawn is harder (230 HB vs 160 HB).

310S Cold DrawnChoose it when strength drives the design.

310S Solution AnnealedChoose it when the part is bent, formed or impact-loaded.

310S Cold Drawn vs 310S Solution Annealed: properties

310S Cold Drawn310S Solution Annealed

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

760 MPa110 ksi
590 MPa85.6 ksi

Yield Strength (0.2% offset)

520 MPa75.4 ksi
260 MPa37.7 ksi

Elongation at Break

25%
45%

Reduction in Area

45%
60%

Fatigue Strength (Endurance Limit)

300 MPa43.5 ksi
240 MPa34.8 ksi

Hardness, Brinell

230 HB
160 HB

Hardness, Rockwell B

98 HRB
82 HRB

Same in both: Elastic (Young's) Modulus 200 GPa29 Msi · Shear Modulus 77 GPa11.2 Msi · Bulk Modulus 152 GPa22 Msi · Poisson's Ratio 0.3 · Compressive Strength 260 MPa37.7 ksi · Shear Strength 380 MPa55.1 ksi · Charpy V-Notch Impact (RT) 130 J95.9 ft·lbf · Hardness, Vickers 170 HV

Physical

Density and transition temperatures.

Same in both: Density 7.98 g/cm³0.29 lb/in³ · Melting Point (Solidus) 1,400°C2,552 °F · Liquidus Temperature 1,450°C2,642 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 14.2 W/m·K8.2 BTU/hr·ft·°F · Specific Heat Capacity 500 J/kg·K0.12 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 15.9 µm/m·K8.8 µin/in·°F · Latent Heat of Fusion 280 J/g120 BTU/lb · Max Service Temperature (continuous) 1,050°C1,922 °F · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 2.2 % IACS · Electrical Resistivity 7.8×10⁻⁷ Ω·m30.7 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.05 V · Corrosion Resistance 66 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability Rating (AISI 1212 = 100 %)

45%
40%

Formability (cold)

45 / 100
70 / 100

Same in both: Machinability 32 / 100 · Weldability 75 / 100 · Castability 55 / 100 · Brazeability / Solderability 60 / 100 · Polishability 75 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 85 MJ/kg36,543 BTU/lb · Embodied Carbon (primary production) 6.5 kg CO₂/kg · Embodied Water 120 L/kg14.4 gal/lb · Typical Recycled Content 55%

Strength versus weight

Yield strength against density for every stainless steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

3005007001,0001,5002,0007.27.47.67.888.2Density (g/cm³)Yield strength (MPa) — log scale310S

310S Cold Drawn vs 310S Solution Annealed — frequently asked

Is 310S Cold Drawn stronger than 310S Solution Annealed?

Yes. 310S Cold Drawn has a typical yield strength of 520 MPa (75.4 ksi) against 260 MPa (37.7 ksi) for 310S Solution Annealed — about 100% more. Tensile strength is 760 MPa (110 ksi) vs 590 MPa (85.6 ksi).

Which condition does FabDigit quote by default, Cold Drawn or Solution Annealed?

Solution Annealed is the default 310S condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose 310S Cold Drawn over 310S Solution Annealed?

Pick 310S Cold Drawn when strength drives the design. Pick 310S Solution Annealed when the part is bent, formed or impact-loaded.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 310S Cold Drawn and 310S Solution Annealed side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.