FabDigitFabDigit

Stainless Steel 301 vs Nitronic 60

Stainless Steel · grade comparison

Stainless Steel 301 and Nitronic 60 are both stainless steel grades. 301 is the stronger of the two: yield strength 570 MPa (82.7 ksi) against 414 MPa (60 ksi) for Nitronic 60, about 38% more; tensile strength follows at 900 MPa (131 ksi) vs 717 MPa (104 ksi). In exchange, Nitronic 60 is the more ductile: elongation 60% versus 25% for 301, and 301 is harder (270 HB vs 210 HB). Nitronic 60 is lighter (7.63 g/cm³ vs 7.88 g/cm³ for 301) and Nitronic 60 runs hotter in service (870°C vs 425°C continuous). On the shop floor, 301 sits in a lower cost tier (premium, $$$) than Nitronic 60 (specialty, $$$$$).

301Choose it when strength drives the design, or when cost is the deciding factor.

Nitronic 60Choose it when the part is bent, formed or impact-loaded, or when weight is the constraint.

301 vs Nitronic 60: properties

301Nitronic 60

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

193 GPa28 Msi
196 GPa28.4 Msi

Bulk Modulus

152 GPa22 Msi
160 GPa23.2 Msi

Poisson's Ratio

0.28
0.29

Tensile Strength (Ultimate)

900 MPa131 ksi
717 MPa104 ksi

Yield Strength (0.2% offset)

570 MPa82.7 ksi
414 MPa60 ksi

Elongation at Break

25%
60%

Reduction in Area

45%
65%

Compressive Strength

580 MPa84.1 ksi
—

Shear Strength

560 MPa81.2 ksi
450 MPa65.3 ksi

Fatigue Strength (Endurance Limit)

400 MPa58 ksi
380 MPa55.1 ksi

Fracture Toughness (K_IC)

110 MPa·√m100 ksi·√in
—

Charpy V-Notch Impact (RT)

60 J44.3 ft·lbf
135 J99.6 ft·lbf

Hardness, Brinell

270 HB
210 HB

Hardness, Rockwell B

100 HRB
95 HRB

Hardness, Rockwell C

27 HRC
—

Hardness, Vickers

285 HV
220 HV

Same in both: Shear Modulus 77 GPa11.2 Msi

Physical

Density and transition temperatures.

Density

7.88 g/cm³0.28 lb/in³
7.63 g/cm³0.28 lb/in³

Melting Point (Solidus)

1,395°C2,543 °F
1,343°C2,449 °F

Liquidus Temperature

1,420°C2,588 °F
1,399°C2,550 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

16.2 W/m·K9.4 BTU/hr·ft·°F
12.9 W/m·K7.5 BTU/hr·ft·°F

Specific Heat Capacity

500 J/kg·K0.12 BTU/lb·°F
502 J/kg·K0.12 BTU/lb·°F

Thermal Expansion (CTE, 20–100 °C)

16.9 µm/m·K9.4 µin/in·°F
15.5 µm/m·K8.6 µin/in·°F

Latent Heat of Fusion

270 J/g116 BTU/lb
—

Max Service Temperature (continuous)

425°C797 °F
870°C1,598 °F

Same in both: Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

2.4 % IACS
2.2 % IACS

Electrical Resistivity

7.2×10⁻⁷ Ω·m28.3 µΩ·in
8×10⁻⁷ Ω·m31.5 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

60 / 100
58 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.1 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

35 / 100
28 / 100

Machinability Rating (AISI 1212 = 100 %)

40%
30%

Weldability

65 / 100
72 / 100

Formability (cold)

65 / 100
58 / 100

Brazeability / Solderability

60 / 100
50 / 100

Polishability

80 / 100
60 / 100

Sustainability

Primary-production footprint per kilogram.

Embodied Carbon (primary production)

5.8 kg CO₂/kg
4.5 kg CO₂/kg

Embodied Water

150 L/kg18 gal/lb
130 L/kg15.6 gal/lb

Same in both: Embodied Energy (primary production) 53 MJ/kg22,786 BTU/lb · Typical Recycled Content 55%

Common Calculations

Ratios derived from the values above.

Specific Strength (UTS / density)

114 kN·m/kg
94 kN·m/kg

Specific Stiffness (E / density)

24.5 MN·m/kg
25.7 MN·m/kg

Modulus of Resilience

842 kJ/m³
437 kJ/m³

Thermal Diffusivity

4.1 mm²/s
3.4 mm²/s

Thermal Shock Resistance Index

4
3

Strength versus weight

Yield strength against density for every stainless steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

3005007001,0001,5002,0007.27.47.67.888.2Density (g/cm³)Yield strength (MPa) — log scale301Nitronic 60

Manufacturing and finishing

Capability301Nitronic 60
CNC machining—Yes
Default conditionCold RolledSolution Annealed
Relative cost$$$ Premium$$$$$ Specialty
Min. machined wall—0.8 mm
Best machined surface—Ra 1.6 µm
AlCrN—Yes
AlTiN—Yes
CVD Al2O3—Yes
CVD TiCN—Yes
CVD TiN—Yes
CrN—Yes
DLC—Yes
HVOF Coating—Yes
MoS2—Yes
Multilayer CVD—Yes
TiAlN—Yes
TiB2—Yes
TiCN—Yes
TiN—Yes
WC/C—Yes
ZrN—Yes

Both are offered for Sheet metal. They share 16 finishes: Black Oxide, Cerakote, Chrome Plating, Electroless Nickel (EN), Electropolishing, Epoxy Coating, Gold Plating, Hard Chrome Plating, Nickel Plating, PTFE Coating, Painting, Passivation (Stainless Steel) and 4 more.

301 vs Nitronic 60 — frequently asked

Is 301 stronger than Nitronic 60?

Yes. 301 has a typical yield strength of 570 MPa (82.7 ksi) against 414 MPa (60 ksi) for Nitronic 60 — about 38% more. Tensile strength is 900 MPa (131 ksi) vs 717 MPa (104 ksi).

Which is cheaper, 301 or Nitronic 60?

301 is the lower-cost material: it sits in the premium tier ($$$) while Nitronic 60 is specialty ($$$$$). Part price depends far more on geometry, tolerance and quantity than on raw stock — upload a CAD file for a live quote.

Which is easier to machine, 301 or Nitronic 60?

301. Its machinability rates fair (35/100) against poor (28/100) for Nitronic 60; for welding the order is Nitronic 60 first (very good, 72/100) then 301 (good, 65/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in 301 and Nitronic 60 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.