Stainless Steel · grade comparison

Stainless Steel 2304 and 329 are both stainless steel grades. 329 is the stronger of the two: yield strength 540 MPa (78.3 ksi) against 460 MPa (66.7 ksi) for 2304, about 17% more; tensile strength follows at 720 MPa (104 ksi) vs 680 MPa (98.6 ksi). In exchange, 2304 is the more ductile: elongation 30% versus 25% for 329. On the shop floor, 2304 welds better (very good vs fair).

2304Choose it when the part is bent, formed or impact-loaded, or when it will be welded.

329Choose it when strength drives the design.

2304 vs 329: properties

2304329

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Bulk Modulus

150 GPa21.8 Msi
145 GPa21 Msi

Tensile Strength (Ultimate)

680 MPa98.6 ksi
720 MPa104 ksi

Yield Strength (0.2% offset)

460 MPa66.7 ksi
540 MPa78.3 ksi

Elongation at Break

30%
25%

Reduction in Area

55%
50%

Compressive Strength

470 MPa68.2 ksi
540 MPa78.3 ksi

Shear Strength

420 MPa60.9 ksi
430 MPa62.4 ksi

Fatigue Strength (Endurance Limit)

400 MPa58 ksi
350 MPa50.8 ksi

Fracture Toughness (K_IC)

120 MPa·√m109 ksi·√in
100 MPa·√m91 ksi·√in

Charpy V-Notch Impact (RT)

220 J162 ft·lbf
80 J59 ft·lbf

Hardness, Brinell

240 HB
230 HB

Hardness, Rockwell B

99 HRB
98 HRB

Hardness, Vickers

250 HV
240 HV

Same in both: Elastic (Young's) Modulus 200 GPa29 Msi · Shear Modulus 77 GPa11.2 Msi · Poisson's Ratio 0.3 · Hardness, Rockwell C 22 HRC

Physical

Density and transition temperatures.

Density

7.75 g/cm³0.28 lb/in³
7.8 g/cm³0.28 lb/in³

Melting Point (Solidus)

1,385°C2,525 °F
1,400°C2,552 °F

Liquidus Temperature

1,445°C2,633 °F
1,450°C2,642 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

16 W/m·K9.2 BTU/hr·ft·°F
15.5 W/m·K9 BTU/hr·ft·°F

Specific Heat Capacity

480 J/kg·K0.11 BTU/lb·°F
460 J/kg·K0.11 BTU/lb·°F

Thermal Expansion (CTE, 20–100 °C)

13 µm/m·K7.2 µin/in·°F
10.9 µm/m·K6.1 µin/in·°F

Latent Heat of Fusion

275 J/g118 BTU/lb
260 J/g112 BTU/lb

Max Service Temperature (continuous)

300°C572 °F
290°C554 °F

Min Service Temperature

-50°C-58 °F
-40°C-40 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 2.2 % IACS · Electrical Resistivity 8×10⁻⁷ Ω·m31.5 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

74 / 100
72 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.15 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

35 / 100
30 / 100

Machinability Rating (AISI 1212 = 100 %)

40%
22%

Weldability

72 / 100
45 / 100

Formability (cold)

55 / 100
40 / 100

Castability

45 / 100
55 / 100

Polishability

70 / 100
65 / 100

Same in both: Brazeability / Solderability 40 / 100

Sustainability

Primary-production footprint per kilogram.

Embodied Energy (primary production)

46 MJ/kg19,776 BTU/lb
55 MJ/kg23,646 BTU/lb

Embodied Carbon (primary production)

3.8 kg CO₂/kg
5.5 kg CO₂/kg

Embodied Water

100 L/kg12 gal/lb
130 L/kg15.6 gal/lb

Typical Recycled Content

70%
60%

Common Calculations

Ratios derived from the values above.

Specific Strength (UTS / density)

88 kN·m/kg
92 kN·m/kg

Specific Stiffness (E / density)

25.8 MN·m/kg
25.6 MN·m/kg

Modulus of Resilience

529 kJ/m³
729 kJ/m³

Thermal Shock Resistance Index

4
5

Same in both: Thermal Diffusivity 4.3 mm²/s

Strength versus weight

Yield strength against density for every stainless steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

3005007001,0001,5002,0007.27.47.67.888.2Density (g/cm³)Yield strength (MPa) — log scale3292304

Manufacturing and finishing

Capability2304329
CNC machiningYes—
Sheet metalYes—
Default conditionSolution Annealed—
Relative cost$$$ Premium$$$ Premium
Min. machined wall0.8 mm—
Best machined surfaceRa 1.6 µm—
AlCrNYes—
AlTiNYes—
Black OxideYes—
CVD Al2O3Yes—
CVD TiCNYes—
CVD TiNYes—
CerakoteYes—
Chrome PlatingYes—
CrNYes—
DLCYes—
ElectropolishingYes—
HVOF CoatingYes—
MoS2Yes—
Multilayer CVDYes—
Nickel PlatingYes—
PTFE CoatingYes—
PaintingYes—
Passivation (Stainless Steel)Yes—

They share 7 finishes: Electroless Nickel (EN), Epoxy Coating, Gold Plating, Hard Chrome Plating, Pickling, Plasma Spray, Silver Plating.

2304 vs 329 — frequently asked

Is 329 stronger than 2304?

Yes. 329 has a typical yield strength of 540 MPa (78.3 ksi) against 460 MPa (66.7 ksi) for 2304 — about 17% more. Tensile strength is 720 MPa (104 ksi) vs 680 MPa (98.6 ksi).

Which is cheaper, 2304 or 329?

Both sit in the same relative cost tier ($$$, premium); the part price will be decided by machining time, tolerance and quantity rather than by the material.

Which is easier to machine, 2304 or 329?

2304. Its machinability rates fair (35/100) against poor (30/100) for 329; for welding the order is 2304 first (very good, 72/100) then 329 (fair, 45/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in 2304 and 329 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.