FabDigitFabDigit

Stainless Steel 17-6PH-H1100 vs 17-6PH-H900

Stainless Steel · 17-6PH temper comparison

17-6PH-H1100 and 17-6PH-H900 are two conditions of the same stainless steel grade, 17-6PH: H1100 (aged 593 °C (1100 °F) for 4 h) versus H900 (aged 482 °C (900 °F) for 1 h, peak hardness). The chemistry is identical, so every difference below comes from the condition. 17-6PH-H900 is the stronger of the two: yield strength 1,275 MPa (185 ksi) against 900 MPa (131 ksi) for 17-6PH-H1100, about 42% more; tensile strength follows at 1,380 MPa (200 ksi) vs 1,035 MPa (150 ksi). In exchange, 17-6PH-H1100 is the more ductile: elongation 15% versus 8% for 17-6PH-H900, and 17-6PH-H900 is harder (45 HRC vs 33 HRC). 17-6PH-H1100 runs hotter in service (400°C vs 300°C continuous). On the shop floor, 17-6PH-H1100 machines more easily (33 vs 22 out of 100).

17-6PH-H1100Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

17-6PH-H900Choose it when strength drives the design.

17-6PH-H1100 vs 17-6PH-H900: properties

17-6PH-H110017-6PH-H900

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

1,035 MPa150 ksi
1,380 MPa200 ksi

Yield Strength (0.2% offset)

900 MPa131 ksi
1,275 MPa185 ksi

Elongation at Break

15%
8%

Reduction in Area

50%
30%

Fatigue Strength (Endurance Limit)

490 MPa71.1 ksi
630 MPa91.4 ksi

Charpy V-Notch Impact (RT)

45 J33.2 ft·lbf
14 J10.3 ft·lbf

Hardness, Rockwell C

33 HRC
45 HRC

Same in both: Elastic (Young's) Modulus 200 GPa29 Msi · Shear Modulus 77 GPa11.2 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.28 · Shear Strength 620 MPa89.9 ksi · Hardness, Brinell 285 HB · Hardness, Vickers 300 HV

Physical

Density and transition temperatures.

Same in both: Density 7.8 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,400°C2,552 °F · Liquidus Temperature 1,450°C2,642 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

400°C752 °F
300°C572 °F

Same in both: Thermal Conductivity 16 W/m·K9.2 BTU/hr·ft·°F · Specific Heat Capacity 460 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 10.8 µm/m·K6 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Min Service Temperature -75°C-103 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 2.2 % IACS · Electrical Resistivity 8×10⁻⁷ Ω·m31.5 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

63 / 100
55 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.25 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

33 / 100
22 / 100

Machinability Rating (AISI 1212 = 100 %)

33%
22%

Weldability

38 / 100
45 / 100

Formability (cold)

22 / 100
10 / 100

Same in both: Brazeability / Solderability 45 / 100 · Polishability 75 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 56 MJ/kg24,076 BTU/lb · Embodied Carbon (primary production) 5 kg CO₂/kg · Embodied Water 210 L/kg25.2 gal/lb · Typical Recycled Content 35%

Strength versus weight

Yield strength against density for every stainless steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

3005007001,0001,5002,0007.27.47.67.888.2Density (g/cm³)Yield strength (MPa) — log scale17-6PH

17-6PH-H1100 vs 17-6PH-H900 — frequently asked

Is 17-6PH-H900 stronger than 17-6PH-H1100?

Yes. 17-6PH-H900 has a typical yield strength of 1,275 MPa (185 ksi) against 900 MPa (131 ksi) for 17-6PH-H1100 — about 42% more. Tensile strength is 1,380 MPa (200 ksi) vs 1,035 MPa (150 ksi).

Which condition does FabDigit quote by default, H1100 or H900?

A is the default 17-6PH condition in the FabDigit quote flow (neither H1100 nor H900). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 17-6PH-H1100 or 17-6PH-H900?

17-6PH-H1100, by a small margin. Both rate poor for machinability — 33/100 against 22/100 for 17-6PH-H900; for welding the order is 17-6PH-H900 first (fair, 45/100) then 17-6PH-H1100 (fair, 38/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in 17-6PH-H1100 and 17-6PH-H900 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.