FabDigitFabDigit

Stainless Steel 17-4 PH Condition A vs 17-4 PH-H1025

Stainless Steel · 17-4 PH temper comparison

17-4 PH Condition A and 17-4 PH-H1025 are two conditions of the same stainless steel grade, 17-4 PH: Condition A (solution annealed) versus H1025 (aged 552 °C (1025 °F) for 4 h). The chemistry is identical, so every difference below comes from the condition. 17-4 PH-H1025 is the stronger of the two: yield strength 1,070 MPa (155 ksi) against 760 MPa (110 ksi) for 17-4 PH Condition A, about 41% more; tensile strength follows at 1,140 MPa (165 ksi) vs 1,030 MPa (149 ksi). 17-4 PH-H1025 is the more ductile: elongation 15% versus 12% for 17-4 PH Condition A, and 17-4 PH-H1025 is harder (352 HB vs 311 HB). 17-4 PH-H1025 runs hotter in service (300°C vs 200°C continuous).

17-4 PH-H1025Choose it when strength drives the design, or when the part is bent, formed or impact-loaded.

17-4 PH Condition A vs 17-4 PH-H1025: properties

17-4 PH Condition A17-4 PH-H1025

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

1,030 MPa149 ksi
1,140 MPa165 ksi

Yield Strength (0.2% offset)

760 MPa110 ksi
1,070 MPa155 ksi

Elongation at Break

12%
15%

Reduction in Area

45%
54%

Fatigue Strength (Endurance Limit)

550 MPa79.8 ksi
600 MPa87 ksi

Fracture Toughness (K_IC)

90 MPa·√m81.9 ksi·√in
95 MPa·√m86.5 ksi·√in

Charpy V-Notch Impact (RT)

35 J25.8 ft·lbf
45 J33.2 ft·lbf

Hardness, Brinell

311 HB
352 HB

Hardness, Rockwell C

33 HRC
38 HRC

Same in both: Elastic (Young's) Modulus 196 GPa28.4 Msi · Shear Modulus 77 GPa11.2 Msi · Bulk Modulus 142 GPa20.6 Msi · Poisson's Ratio 0.27 · Compressive Strength 790 MPa115 ksi · Shear Strength 660 MPa95.7 ksi · Hardness, Vickers 330 HV

Physical

Density and transition temperatures.

Same in both: Density 7.78 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,404°C2,559 °F · Liquidus Temperature 1,440°C2,624 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

200°C392 °F
300°C572 °F

Same in both: Thermal Conductivity 16.3 W/m·K9.4 BTU/hr·ft·°F · Specific Heat Capacity 460 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 10.8 µm/m·K6 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Min Service Temperature -73°C-99 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 2.2 % IACS · Electrical Resistivity 8×10⁻⁷ Ω·m31.5 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.15 V · Corrosion Resistance 52 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability Rating (AISI 1212 = 100 %)

48%
40%

Same in both: Machinability 45 / 100 · Weldability 70 / 100 · Formability (cold) 35 / 100 · Castability 65 / 100 · Brazeability / Solderability 45 / 100 · Polishability 75 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 55 MJ/kg23,646 BTU/lb · Embodied Carbon (primary production) 5.2 kg CO₂/kg · Embodied Water 200 L/kg24 gal/lb · Typical Recycled Content 50%

Strength versus weight

Yield strength against density for every stainless steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

3005007001,0001,5002,0007.27.47.67.888.2Density (g/cm³)Yield strength (MPa) — log scale17-4 PH

17-4 PH Condition A vs 17-4 PH-H1025 — frequently asked

Is 17-4 PH-H1025 stronger than 17-4 PH Condition A?

Yes. 17-4 PH-H1025 has a typical yield strength of 1,070 MPa (155 ksi) against 760 MPa (110 ksi) for 17-4 PH Condition A — about 41% more. Tensile strength is 1,140 MPa (165 ksi) vs 1,030 MPa (149 ksi).

Which condition does FabDigit quote by default, Condition A or H1025?

Condition A is the default 17-4 PH condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose 17-4 PH Condition A over 17-4 PH-H1025?

Pick 17-4 PH-H1025 when strength drives the design, or when the part is bent, formed or impact-loaded.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 17-4 PH Condition A and 17-4 PH-H1025 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.