FabDigitFabDigit

Stainless Steel 15Cr25Ti-CD vs 15Cr25Ti-HR

Stainless Steel · 15Cr25Ti temper comparison

15Cr25Ti-CD and 15Cr25Ti-HR are two conditions of the same stainless steel grade, 15Cr25Ti: CD (cold drawn) versus HR (hot rolled). The chemistry is identical, so every difference below comes from the condition. 15Cr25Ti-CD is the stronger of the two: yield strength 500 MPa (72.5 ksi) against 360 MPa (52.2 ksi) for 15Cr25Ti-HR, about 39% more; tensile strength follows at 640 MPa (92.8 ksi) vs 560 MPa (81.2 ksi). In exchange, 15Cr25Ti-HR is the more ductile: elongation 18% versus 12% for 15Cr25Ti-CD, and 15Cr25Ti-CD is harder (225 HB vs 205 HB).

15Cr25Ti-CDChoose it when strength drives the design.

15Cr25Ti-HRChoose it when the part is bent, formed or impact-loaded.

15Cr25Ti-CD vs 15Cr25Ti-HR: properties

15Cr25Ti-CD15Cr25Ti-HR

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

640 MPa92.8 ksi
560 MPa81.2 ksi

Yield Strength (0.2% offset)

500 MPa72.5 ksi
360 MPa52.2 ksi

Elongation at Break

12%
18%

Reduction in Area

35%
38%

Shear Strength

340 MPa49.3 ksi
365 MPa52.9 ksi

Fatigue Strength (Endurance Limit)

280 MPa40.6 ksi
255 MPa37 ksi

Fracture Toughness (K_IC)

45 MPa·√m41 ksi·√in
35 MPa·√m31.9 ksi·√in

Charpy V-Notch Impact (RT)

8 J5.9 ft·lbf
10 J7.4 ft·lbf

Hardness, Brinell

225 HB
205 HB

Hardness, Rockwell B

97 HRB
93 HRB

Hardness, Vickers

190 HV
215 HV

Same in both: Elastic (Young's) Modulus 200 GPa29 Msi · Shear Modulus 78 GPa11.3 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Same in both: Density 7.6 g/cm³0.27 lb/in³ · Melting Point (Solidus) 1,425°C2,597 °F · Liquidus Temperature 1,510°C2,750 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 21 W/m·K12.1 BTU/hr·ft·°F · Specific Heat Capacity 500 J/kg·K0.12 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 10.4 µm/m·K5.8 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Max Service Temperature (continuous) 1,050°C1,922 °F · Min Service Temperature -20°C-4 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 2.6 % IACS · Electrical Resistivity 6.7×10⁻⁷ Ω·m26.4 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

62 / 100
58 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.2 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

45 / 100
42 / 100

Machinability Rating (AISI 1212 = 100 %)

50%
42%

Weldability

40 / 100
38 / 100

Formability (cold)

25 / 100
35 / 100

Same in both: Brazeability / Solderability 55 / 100 · Polishability 55 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 52 MJ/kg22,356 BTU/lb · Embodied Carbon (primary production) 4.6 kg CO₂/kg · Embodied Water 190 L/kg22.8 gal/lb · Typical Recycled Content 60%

Strength versus weight

Yield strength against density for every stainless steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

3005007001,0001,5002,0007.27.47.67.888.2Density (g/cm³)Yield strength (MPa) — log scale15Cr25Ti

15Cr25Ti-CD vs 15Cr25Ti-HR — frequently asked

Is 15Cr25Ti-CD stronger than 15Cr25Ti-HR?

Yes. 15Cr25Ti-CD has a typical yield strength of 500 MPa (72.5 ksi) against 360 MPa (52.2 ksi) for 15Cr25Ti-HR — about 39% more. Tensile strength is 640 MPa (92.8 ksi) vs 560 MPa (81.2 ksi).

Which condition does FabDigit quote by default, CD or HR?

Annealed is the default 15Cr25Ti condition in the FabDigit quote flow (neither CD nor HR). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose 15Cr25Ti-CD over 15Cr25Ti-HR?

Pick 15Cr25Ti-CD when strength drives the design. Pick 15Cr25Ti-HR when the part is bent, formed or impact-loaded.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 15Cr25Ti-CD and 15Cr25Ti-HR side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.