Stainless Steel 1.4982-CD vs 1.4982-ST

Stainless Steel · 1.4982 temper comparison

1.4982-CD and 1.4982-ST are two conditions of the same stainless steel grade, 1.4982: CD (cold drawn) versus ST (solution annealed). The chemistry is identical, so every difference below comes from the condition. 1.4982-CD is the stronger of the two: yield strength 600 MPa (87 ksi) against 330 MPa (47.9 ksi) for 1.4982-ST, about 82% more; tensile strength follows at 800 MPa (116 ksi) vs 660 MPa (95.7 ksi). In exchange, 1.4982-ST is the more ductile: elongation 45% versus 22% for 1.4982-CD, and 1.4982-CD is harder (250 HB vs 185 HB). 1.4982-ST runs hotter in service (700°C vs 600°C continuous).

1.4982-CDChoose it when strength drives the design.

1.4982-STChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

1.4982-CD vs 1.4982-ST: properties

1.4982-CD1.4982-ST

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

800 MPa116 ksi
660 MPa95.7 ksi

Yield Strength (0.2% offset)

600 MPa87 ksi
330 MPa47.9 ksi

Elongation at Break

22%
45%

Reduction in Area

45%
60%

Fatigue Strength (Endurance Limit)

330 MPa47.9 ksi
280 MPa40.6 ksi

Charpy V-Notch Impact (RT)

80 J59 ft·lbf
150 J111 ft·lbf

Hardness, Brinell

250 HB
185 HB

Hardness, Rockwell B

100 HRB
90 HRB

Same in both: Elastic (Young's) Modulus 200 GPa29 Msi · Shear Modulus 77 GPa11.2 Msi · Bulk Modulus 166 GPa24.1 Msi · Poisson's Ratio 0.3 · Shear Strength 430 MPa62.4 ksi · Hardness, Vickers 195 HV

Physical

Density and transition temperatures.

Same in both: Density 7.9 g/cm³0.29 lb/in³ · Melting Point (Solidus) 1,370°C2,498 °F · Liquidus Temperature 1,420°C2,588 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

600°C1,112 °F
700°C1,292 °F

Same in both: Thermal Conductivity 14.5 W/m·K8.4 BTU/hr·ft·°F · Specific Heat Capacity 500 J/kg·K0.12 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 17 µm/m·K9.4 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 2 % IACS · Electrical Resistivity 8.6×10⁻⁷ Ω·m33.9 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.1 V · Corrosion Resistance 58 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

35 / 100
30 / 100

Formability (cold)

35 / 100
60 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 30% · Weldability 70 / 100 · Brazeability / Solderability 50 / 100 · Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 58 MJ/kg24,936 BTU/lb · Embodied Carbon (primary production) 4.6 kg CO₂/kg · Embodied Water 130 L/kg15.6 gal/lb · Typical Recycled Content 40%

Strength versus weight

Yield strength against density for every stainless steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

3005007001,0001,5002,0007.27.47.67.888.2Density (g/cm³)Yield strength (MPa) — log scale1.4982

1.4982-CD vs 1.4982-ST — frequently asked

Is 1.4982-CD stronger than 1.4982-ST?

Yes. 1.4982-CD has a typical yield strength of 600 MPa (87 ksi) against 330 MPa (47.9 ksi) for 1.4982-ST — about 82% more. Tensile strength is 800 MPa (116 ksi) vs 660 MPa (95.7 ksi).

Which condition does FabDigit quote by default, CD or ST?

ST is the default 1.4982 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 1.4982-CD or 1.4982-ST?

1.4982-CD. Its machinability rates fair (35/100) against poor (30/100) for 1.4982-ST.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 1.4982-CD and 1.4982-ST side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.