FabDigitFabDigit

Stainless Steel 1.4821 +A vs 1.4821 +AT

Stainless Steel · 1.4821 temper comparison

1.4821 +A and 1.4821 +AT are two conditions of the same stainless steel grade, 1.4821: +A (annealed) versus +AT (solution annealed). The chemistry is identical, so every difference below comes from the condition. 1.4821 +AT is the stronger of the two: yield strength 470 MPa (68.2 ksi) against 440 MPa (63.8 ksi) for 1.4821 +A, about 7% more; tensile strength follows at 780 MPa (113 ksi) vs 740 MPa (107 ksi). 1.4821 +AT is the more ductile: elongation 20% versus 18% for 1.4821 +A, and 1.4821 +AT is harder (230 HB vs 215 HB).

1.4821 +ATChoose it when strength drives the design, or when the part is bent, formed or impact-loaded.

1.4821 +A vs 1.4821 +AT: properties

1.4821 +A1.4821 +AT

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

740 MPa107 ksi
780 MPa113 ksi

Yield Strength (0.2% offset)

440 MPa63.8 ksi
470 MPa68.2 ksi

Elongation at Break

18%
20%

Reduction in Area

33%
30%

Compressive Strength

450 MPa65.3 ksi
480 MPa69.6 ksi

Shear Strength

455 MPa66 ksi
480 MPa69.6 ksi

Fatigue Strength (Endurance Limit)

300 MPa43.5 ksi
320 MPa46.4 ksi

Fracture Toughness (K_IC)

60 MPa·√m54.6 ksi·√in
55 MPa·√m50.1 ksi·√in

Charpy V-Notch Impact (RT)

25 J18.4 ft·lbf
30 J22.1 ft·lbf

Hardness, Brinell

215 HB
230 HB

Hardness, Rockwell B

95 HRB
98 HRB

Hardness, Rockwell C

17 HRC
20 HRC

Hardness, Vickers

225 HV
240 HV

Same in both: Elastic (Young's) Modulus 200 GPa29 Msi · Shear Modulus 77 GPa11.2 Msi · Bulk Modulus 155 GPa22.5 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Same in both: Density 7.7 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,400°C2,552 °F · Liquidus Temperature 1,450°C2,642 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 15 W/m·K8.7 BTU/hr·ft·°F · Specific Heat Capacity 500 J/kg·K0.12 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 11 µm/m·K6.1 µin/in·°F · Max Service Temperature (continuous) 1,100°C2,012 °F · Min Service Temperature -20°C-4 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 1.9 % IACS · Electrical Resistivity 9×10⁻⁷ Ω·m35.4 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Corrosion Resistance 65 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

32 / 100
30 / 100

Machinability Rating (AISI 1212 = 100 %)

32%
30%

Formability (cold)

33 / 100
30 / 100

Same in both: Weldability 35 / 100 · Brazeability / Solderability 45 / 100 · Polishability 55 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 50 MJ/kg21,496 BTU/lb · Embodied Carbon (primary production) 4.5 kg CO₂/kg · Embodied Water 120 L/kg14.4 gal/lb · Typical Recycled Content 65%

Strength versus weight

Yield strength against density for every stainless steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

3005007001,0001,5002,0007.27.47.67.888.2Density (g/cm³)Yield strength (MPa) — log scale1.4821

1.4821 +A vs 1.4821 +AT — frequently asked

Is 1.4821 +AT stronger than 1.4821 +A?

Yes. 1.4821 +AT has a typical yield strength of 470 MPa (68.2 ksi) against 440 MPa (63.8 ksi) for 1.4821 +A — about 7% more. Tensile strength is 780 MPa (113 ksi) vs 740 MPa (107 ksi).

Which condition does FabDigit quote by default, +A or +AT?

+AT is the default 1.4821 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose 1.4821 +A over 1.4821 +AT?

Pick 1.4821 +AT when strength drives the design, or when the part is bent, formed or impact-loaded.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 1.4821 +A and 1.4821 +AT side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.