FabDigitFabDigit

Stainless Steel 1.4742-A vs 1.4742-C

Stainless Steel · 1.4742 temper comparison

1.4742-A and 1.4742-C are two conditions of the same stainless steel grade, 1.4742: A (solution annealed) versus C. The chemistry is identical, so every difference below comes from the condition. 1.4742-C is the stronger of the two: yield strength 540 MPa (78.3 ksi) against 300 MPa (43.5 ksi) for 1.4742-A, about 80% more; tensile strength follows at 700 MPa (102 ksi) vs 600 MPa (87 ksi). In exchange, 1.4742-A is the more ductile: elongation 20% versus 12% for 1.4742-C, and 1.4742-C is harder (225 HB vs 180 HB).

1.4742-AChoose it when the part is bent, formed or impact-loaded.

1.4742-CChoose it when strength drives the design.

1.4742-A vs 1.4742-C: properties

1.4742-A1.4742-C

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

600 MPa87 ksi
700 MPa102 ksi

Yield Strength (0.2% offset)

300 MPa43.5 ksi
540 MPa78.3 ksi

Elongation at Break

20%
12%

Reduction in Area

45%
35%

Shear Strength

390 MPa56.6 ksi
450 MPa65.3 ksi

Fatigue Strength (Endurance Limit)

260 MPa37.7 ksi
300 MPa43.5 ksi

Charpy V-Notch Impact (RT)

25 J18.4 ft·lbf
14 J10.3 ft·lbf

Hardness, Brinell

180 HB
225 HB

Hardness, Rockwell B

88 HRB
98 HRB

Hardness, Vickers

190 HV
235 HV

Same in both: Elastic (Young's) Modulus 220 GPa31.9 Msi · Shear Modulus 85 GPa12.3 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.3

Physical

Density and transition temperatures.

Same in both: Density 7.7 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,450°C2,642 °F · Liquidus Temperature 1,510°C2,750 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 17 W/m·K9.8 BTU/hr·ft·°F · Specific Heat Capacity 500 J/kg·K0.12 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 11.5 µm/m·K6.4 µin/in·°F · Latent Heat of Fusion 260 J/g112 BTU/lb · Max Service Temperature (continuous) 1,000°C1,832 °F · Min Service Temperature -20°C-4 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 1.7 % IACS · Electrical Resistivity 1×10⁻⁶ Ω·m39.4 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

45 / 100
44 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.25 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

40 / 100
48 / 100

Machinability Rating (AISI 1212 = 100 %)

45%
52%

Weldability

40 / 100
33 / 100

Formability (cold)

50 / 100
30 / 100

Same in both: Brazeability / Solderability 50 / 100 · Polishability 50 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 52 MJ/kg22,356 BTU/lb · Embodied Carbon (primary production) 3.6 kg CO₂/kg · Embodied Water 110 L/kg13.2 gal/lb · Typical Recycled Content 60%

Strength versus weight

Yield strength against density for every stainless steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

3005007001,0001,5002,0007.27.47.67.888.2Density (g/cm³)Yield strength (MPa) — log scale1.4742

1.4742-A vs 1.4742-C — frequently asked

Is 1.4742-C stronger than 1.4742-A?

Yes. 1.4742-C has a typical yield strength of 540 MPa (78.3 ksi) against 300 MPa (43.5 ksi) for 1.4742-A — about 80% more. Tensile strength is 700 MPa (102 ksi) vs 600 MPa (87 ksi).

Which condition does FabDigit quote by default, A or C?

A is the default 1.4742 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 1.4742-A or 1.4742-C?

1.4742-C, by a small margin. Both rate fair for machinability — 48/100 against 40/100 for 1.4742-A; for welding the order is 1.4742-A first (fair, 40/100) then 1.4742-C (poor, 33/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in 1.4742-A and 1.4742-C side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.