FabDigitFabDigit

Stainless Steel 1.4729-A vs 1.4729-SR

Stainless Steel · 1.4729 temper comparison

1.4729-A and 1.4729-SR are two conditions of the same stainless steel grade, 1.4729: A (solution annealed) versus SR (stress relieved). The chemistry is identical, so every difference below comes from the condition. Both yield at about 420 MPa — the mechanical properties are the same, and the difference is in how the stock is processed and what it is certified to (solution annealed versus stress relieved). 1.4729-A is the more ductile: elongation 10% versus 8% for 1.4729-SR, and 1.4729-SR is harder (245 HB vs 230 HB).

1.4729-AChoose it when the part is bent, formed or impact-loaded.

1.4729-A vs 1.4729-SR: properties

1.4729-A1.4729-SR

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

680 MPa98.6 ksi
700 MPa102 ksi

Yield Strength (0.2% offset)

420 MPa60.9 ksi
440 MPa63.8 ksi

Elongation at Break

10%
8%

Reduction in Area

18%
14%

Compressive Strength

700 MPa102 ksi
720 MPa104 ksi

Shear Strength

440 MPa63.8 ksi
450 MPa65.3 ksi

Fatigue Strength (Endurance Limit)

280 MPa40.6 ksi
285 MPa41.3 ksi

Fracture Toughness (K_IC)

35 MPa·√m31.9 ksi·√in
30 MPa·√m27.3 ksi·√in

Charpy V-Notch Impact (RT)

10 J7.4 ft·lbf
9 J6.6 ft·lbf

Hardness, Brinell

230 HB
245 HB

Hardness, Rockwell C

21 HRC
23 HRC

Hardness, Vickers

240 HV
257 HV

Same in both: Elastic (Young's) Modulus 215 GPa31.2 Msi · Shear Modulus 83 GPa12 Msi · Bulk Modulus 165 GPa23.9 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Same in both: Density 7.7 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,400°C2,552 °F · Liquidus Temperature 1,470°C2,678 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 24 W/m·K13.9 BTU/hr·ft·°F · Specific Heat Capacity 460 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 10.5 µm/m·K5.8 µin/in·°F · Latent Heat of Fusion 260 J/g112 BTU/lb · Max Service Temperature (continuous) 850°C1,562 °F · Min Service Temperature -20°C-4 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 2.5 % IACS · Electrical Resistivity 7×10⁻⁷ Ω·m27.6 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.3 V · Corrosion Resistance 45 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

35 / 100
33 / 100

Machinability Rating (AISI 1212 = 100 %)

40%
37%

Weldability

25 / 100
24 / 100

Formability (cold)

8 / 100
7 / 100

Same in both: Castability 65 / 100 · Brazeability / Solderability 40 / 100 · Polishability 55 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 45 MJ/kg19,347 BTU/lb · Embodied Carbon (primary production) 3.4 kg CO₂/kg · Embodied Water 130 L/kg15.6 gal/lb · Typical Recycled Content 70%

Strength versus weight

Yield strength against density for every stainless steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

3005007001,0001,5002,0007.27.47.67.888.2Density (g/cm³)Yield strength (MPa) — log scale1.4729

1.4729-A vs 1.4729-SR — frequently asked

What is the difference between 1.4729-A and 1.4729-SR?

1.4729-A and 1.4729-SR are two conditions of the same stainless steel grade, 1.4729: A (solution annealed) versus SR (stress relieved). The chemistry is identical, so every difference below comes from the condition. Both yield at about 420 MPa — the mechanical properties are the same, and the difference is in how the stock is processed and what it is certified to (solution annealed versus stress relieved).

Which condition does FabDigit quote by default, A or SR?

A is the default 1.4729 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose 1.4729-A over 1.4729-SR?

Pick 1.4729-A when the part is bent, formed or impact-loaded.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 1.4729-A and 1.4729-SR side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.