FabDigitFabDigit

Stainless Steel 1.4710-A vs 1.4710-AC

Stainless Steel · 1.4710 temper comparison

1.4710-A and 1.4710-AC are two conditions of the same stainless steel grade, 1.4710: A (solution annealed) versus AC (spheroidize annealed). The chemistry is identical, so every difference below comes from the condition. 1.4710-AC is the stronger of the two: yield strength 400 MPa (58 ksi) against 290 MPa (42.1 ksi) for 1.4710-A, about 38% more; tensile strength follows at 640 MPa (92.8 ksi) vs 520 MPa (75.4 ksi). In exchange, 1.4710-A is the more ductile: elongation 6% versus 2% for 1.4710-AC, and 1.4710-AC is harder (265 HB vs 205 HB). On the shop floor, 1.4710-A machines more easily (fair vs poor).

1.4710-AChoose it when the part is bent, formed or impact-loaded, or when the part is machined in volume.

1.4710-ACChoose it when strength drives the design.

1.4710-A vs 1.4710-AC: properties

1.4710-A1.4710-AC

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

520 MPa75.4 ksi
640 MPa92.8 ksi

Yield Strength (0.2% offset)

290 MPa42.1 ksi
400 MPa58 ksi

Elongation at Break

6%
2%

Reduction in Area

8%
3%

Compressive Strength

550 MPa79.8 ksi
680 MPa98.6 ksi

Shear Strength

370 MPa53.7 ksi
455 MPa66 ksi

Fatigue Strength (Endurance Limit)

210 MPa30.5 ksi
255 MPa37 ksi

Charpy V-Notch Impact (RT)

8 J5.9 ft·lbf
4 J3 ft·lbf

Hardness, Brinell

205 HB
265 HB

Hardness, Vickers

215 HV
278 HV

Same in both: Elastic (Young's) Modulus 205 GPa29.7 Msi · Shear Modulus 79 GPa11.5 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Same in both: Density 7.65 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,400°C2,552 °F · Liquidus Temperature 1,470°C2,678 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 26 W/m·K15 BTU/hr·ft·°F · Specific Heat Capacity 470 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 11.5 µm/m·K6.4 µin/in·°F · Latent Heat of Fusion 265 J/g114 BTU/lb · Max Service Temperature (continuous) 850°C1,562 °F · Min Service Temperature 0°C32 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Resistivity 7.2×10⁻⁷ Ω·m28.3 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

30 / 100
28 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

40 / 100
25 / 100

Machinability Rating (AISI 1212 = 100 %)

40%
25%

Weldability

30 / 100
22 / 100

Formability (cold)

5 / 100
3 / 100

Same in both: Castability 70 / 100 · Brazeability / Solderability 35 / 100 · Polishability 40 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 34 MJ/kg14,617 BTU/lb · Embodied Carbon (primary production) 2.6 kg CO₂/kg · Embodied Water 60 L/kg7.2 gal/lb · Typical Recycled Content 80%

Strength versus weight

Yield strength against density for every stainless steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

3005007001,0001,5002,0007.27.47.67.888.2Density (g/cm³)Yield strength (MPa) — log scale1.4710

1.4710-A vs 1.4710-AC — frequently asked

Is 1.4710-AC stronger than 1.4710-A?

Yes. 1.4710-AC has a typical yield strength of 400 MPa (58 ksi) against 290 MPa (42.1 ksi) for 1.4710-A — about 38% more. Tensile strength is 640 MPa (92.8 ksi) vs 520 MPa (75.4 ksi).

Which condition does FabDigit quote by default, A or AC?

A is the default 1.4710 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 1.4710-A or 1.4710-AC?

1.4710-A. Its machinability rates fair (40/100) against poor (25/100) for 1.4710-AC; for welding the order is 1.4710-A first (poor, 30/100) then 1.4710-AC (poor, 22/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in 1.4710-A and 1.4710-AC side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.