FabDigitFabDigit

Stainless Steel 1.4662-AT vs 1.4662-CD

Stainless Steel · 1.4662 temper comparison

1.4662-AT and 1.4662-CD are two conditions of the same stainless steel grade, 1.4662: AT (solution annealed and quenched) versus CD (cold drawn). The chemistry is identical, so every difference below comes from the condition. 1.4662-CD is the stronger of the two: yield strength 680 MPa (98.6 ksi) against 520 MPa (75.4 ksi) for 1.4662-AT, about 31% more; tensile strength follows at 850 MPa (123 ksi) vs 750 MPa (109 ksi). In exchange, 1.4662-AT is the more ductile: elongation 30% versus 20% for 1.4662-CD, and 1.4662-CD is harder (285 HB vs 245 HB).

1.4662-ATChoose it when the part is bent, formed or impact-loaded.

1.4662-CDChoose it when strength drives the design.

1.4662-AT vs 1.4662-CD: properties

1.4662-AT1.4662-CD

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

750 MPa109 ksi
850 MPa123 ksi

Yield Strength (0.2% offset)

520 MPa75.4 ksi
680 MPa98.6 ksi

Elongation at Break

30%
20%

Reduction in Area

55%
45%

Compressive Strength

530 MPa76.9 ksi
700 MPa102 ksi

Shear Strength

455 MPa66 ksi
510 MPa74 ksi

Fatigue Strength (Endurance Limit)

390 MPa56.6 ksi
430 MPa62.4 ksi

Fracture Toughness (K_IC)

110 MPa·√m100 ksi·√in
90 MPa·√m81.9 ksi·√in

Charpy V-Notch Impact (RT)

150 J111 ft·lbf
80 J59 ft·lbf

Hardness, Brinell

245 HB
285 HB

Hardness, Rockwell B

99 HRB
103 HRB

Hardness, Rockwell C

23 HRC
29 HRC

Hardness, Vickers

255 HV
300 HV

Same in both: Elastic (Young's) Modulus 200 GPa29 Msi · Shear Modulus 77 GPa11.2 Msi · Bulk Modulus 152 GPa22 Msi · Poisson's Ratio 0.3

Physical

Density and transition temperatures.

Same in both: Density 7.7 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,385°C2,525 °F · Liquidus Temperature 1,440°C2,624 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 15 W/m·K8.7 BTU/hr·ft·°F · Specific Heat Capacity 480 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 13 µm/m·K7.2 µin/in·°F · Max Service Temperature (continuous) 300°C572 °F · Min Service Temperature -40°C-40 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 2.2 % IACS · Electrical Resistivity 8×10⁻⁷ Ω·m31.5 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

77 / 100
76 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.15 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

32 / 100
28 / 100

Machinability Rating (AISI 1212 = 100 %)

27%
22%

Weldability

75 / 100
70 / 100

Formability (cold)

50 / 100
30 / 100

Same in both: Brazeability / Solderability 35 / 100 · Polishability 68 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 52 MJ/kg22,356 BTU/lb · Embodied Carbon (primary production) 4.8 kg CO₂/kg · Embodied Water 140 L/kg16.8 gal/lb · Typical Recycled Content 75%

Strength versus weight

Yield strength against density for every stainless steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

3005007001,0001,5002,0007.27.47.67.888.2Density (g/cm³)Yield strength (MPa) — log scale1.4662

1.4662-AT vs 1.4662-CD — frequently asked

Is 1.4662-CD stronger than 1.4662-AT?

Yes. 1.4662-CD has a typical yield strength of 680 MPa (98.6 ksi) against 520 MPa (75.4 ksi) for 1.4662-AT — about 31% more. Tensile strength is 850 MPa (123 ksi) vs 750 MPa (109 ksi).

Which condition does FabDigit quote by default, AT or CD?

Specify the condition in the material field or the drawing note; FabDigit prices the quote for the state you call out.

Which welds better, 1.4662-AT or 1.4662-CD?

1.4662-AT. Its weldability rates very good (75/100) against very good (70/100) for 1.4662-CD.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 1.4662-AT and 1.4662-CD side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.