1.4650 +AT and 1.4650 +LC are two conditions of the same stainless steel grade, 1.4650: +AT (solution annealed) versus +LC (annealed and lightly cold drawn). The chemistry is identical, so every difference below comes from the condition. 1.4650 +LC is the stronger of the two: yield strength 320 MPa (46.4 ksi) against 220 MPa (31.9 ksi) for 1.4650 +AT, about 45% more; tensile strength follows at 620 MPa (89.9 ksi) vs 570 MPa (82.7 ksi). In exchange, 1.4650 +AT is the more ductile: elongation 50% versus 40% for 1.4650 +LC, and 1.4650 +LC is harder (180 HB vs 150 HB). 1.4650 +AT runs hotter in service (400°C vs 350°C continuous).

1.4650 +ATChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

1.4650 +LCChoose it when strength drives the design.

1.4650 +AT vs 1.4650 +LC: properties

1.4650 +AT1.4650 +LC

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

200 GPa29 Msi
195 GPa28.3 Msi

Tensile Strength (Ultimate)

570 MPa82.7 ksi
620 MPa89.9 ksi

Yield Strength (0.2% offset)

220 MPa31.9 ksi
320 MPa46.4 ksi

Elongation at Break

50%
40%

Reduction in Area

70%
65%

Shear Strength

400 MPa58 ksi
390 MPa56.6 ksi

Fatigue Strength (Endurance Limit)

240 MPa34.8 ksi
265 MPa38.4 ksi

Fracture Toughness (K_IC)

200 MPa·√m182 ksi·√in
180 MPa·√m164 ksi·√in

Charpy V-Notch Impact (RT)

150 J111 ft·lbf
130 J95.9 ft·lbf

Hardness, Brinell

150 HB
180 HB

Hardness, Rockwell B

80 HRB
88 HRB

Hardness, Vickers

160 HV
190 HV

Same in both: Shear Modulus 77 GPa11.2 Msi · Bulk Modulus 145 GPa21 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Same in both: Density 7.9 g/cm³0.29 lb/in³ · Melting Point (Solidus) 1,400°C2,552 °F · Liquidus Temperature 1,450°C2,642 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

400°C752 °F
350°C662 °F

Same in both: Thermal Conductivity 15 W/m·K8.7 BTU/hr·ft·°F · Specific Heat Capacity 500 J/kg·K0.12 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 16.5 µm/m·K9.2 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 2.4 % IACS · Electrical Resistivity 7.3×10⁻⁷ Ω·m28.7 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.08 V · Corrosion Resistance 65 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

40 / 100
43 / 100

Machinability Rating (AISI 1212 = 100 %)

45%
50%

Formability (cold)

97 / 100
92 / 100

Same in both: Weldability 88 / 100 · Brazeability / Solderability 70 / 100 · Polishability 85 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 57 MJ/kg24,506 BTU/lb · Embodied Carbon (primary production) 4.5 kg CO₂/kg · Embodied Water 130 L/kg15.6 gal/lb · Typical Recycled Content 65%

Strength versus weight

Yield strength against density for every stainless steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

3005007001,0001,5002,0007.27.47.67.888.2Density (g/cm³)Yield strength (MPa) — log scale1.4650

1.4650 +AT vs 1.4650 +LC — frequently asked

Is 1.4650 +LC stronger than 1.4650 +AT?

Yes. 1.4650 +LC has a typical yield strength of 320 MPa (46.4 ksi) against 220 MPa (31.9 ksi) for 1.4650 +AT — about 45% more. Tensile strength is 620 MPa (89.9 ksi) vs 570 MPa (82.7 ksi).

Which condition does FabDigit quote by default, +AT or +LC?

+AT is the default 1.4650 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose 1.4650 +AT over 1.4650 +LC?

Pick 1.4650 +AT when the part is bent, formed or impact-loaded, or when the part sees heat. Pick 1.4650 +LC when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 1.4650 +AT and 1.4650 +LC side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.