FabDigitFabDigit

Stainless Steel 1.4570 +AT vs 1.4570 +CG

Stainless Steel · 1.4570 temper comparison

1.4570 +AT and 1.4570 +CG are two conditions of the same stainless steel grade, 1.4570: +AT (solution annealed) versus +CG (+CG / h6). The chemistry is identical, so every difference below comes from the condition. 1.4570 +CG is the stronger of the two: yield strength 520 MPa (75.4 ksi) against 260 MPa (37.7 ksi) for 1.4570 +AT, about 100% more; tensile strength follows at 720 MPa (104 ksi) vs 600 MPa (87 ksi). In exchange, 1.4570 +AT is the more ductile: elongation 45% versus 16% for 1.4570 +CG, and 1.4570 +CG is harder (225 HB vs 175 HB). 1.4570 +AT runs hotter in service (760°C vs 400°C continuous).

1.4570 +ATChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

1.4570 +CGChoose it when strength drives the design.

1.4570 +AT vs 1.4570 +CG: properties

1.4570 +AT1.4570 +CG

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

600 MPa87 ksi
720 MPa104 ksi

Yield Strength (0.2% offset)

260 MPa37.7 ksi
520 MPa75.4 ksi

Elongation at Break

45%
16%

Reduction in Area

55%
45%

Compressive Strength

260 MPa37.7 ksi
520 MPa75.4 ksi

Shear Strength

420 MPa60.9 ksi
435 MPa63.1 ksi

Fatigue Strength (Endurance Limit)

250 MPa36.3 ksi
290 MPa42.1 ksi

Fracture Toughness (K_IC)

100 MPa·√m91 ksi·√in
85 MPa·√m77.4 ksi·√in

Charpy V-Notch Impact (RT)

40 J29.5 ft·lbf
32 J23.6 ft·lbf

Hardness, Brinell

175 HB
225 HB

Hardness, Rockwell B

88 HRB
97 HRB

Hardness, Vickers

185 HV
235 HV

Same in both: Elastic (Young's) Modulus 193 GPa28 Msi · Shear Modulus 77 GPa11.2 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.3

Physical

Density and transition temperatures.

Same in both: Density 7.9 g/cm³0.29 lb/in³ · Melting Point (Solidus) 1,400°C2,552 °F · Liquidus Temperature 1,425°C2,597 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

760°C1,400 °F
400°C752 °F

Same in both: Thermal Conductivity 15 W/m·K8.7 BTU/hr·ft·°F · Specific Heat Capacity 500 J/kg·K0.12 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 16.5 µm/m·K9.2 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Min Service Temperature -100°C-148 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 2.4 % IACS · Electrical Resistivity 7.3×10⁻⁷ Ω·m28.7 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

55 / 100
58 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.1 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

72 / 100
74 / 100

Machinability Rating (AISI 1212 = 100 %)

78%
80%

Formability (cold)

35 / 100
25 / 100

Polishability

40 / 100
45 / 100

Same in both: Weldability 20 / 100 · Brazeability / Solderability 55 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 53 MJ/kg22,786 BTU/lb · Embodied Carbon (primary production) 5 kg CO₂/kg · Embodied Water 180 L/kg21.6 gal/lb · Typical Recycled Content 65%

Strength versus weight

Yield strength against density for every stainless steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

3005007001,0001,5002,0007.27.47.67.888.2Density (g/cm³)Yield strength (MPa) — log scale1.4570

1.4570 +AT vs 1.4570 +CG — frequently asked

Is 1.4570 +CG stronger than 1.4570 +AT?

Yes. 1.4570 +CG has a typical yield strength of 520 MPa (75.4 ksi) against 260 MPa (37.7 ksi) for 1.4570 +AT — about 100% more. Tensile strength is 720 MPa (104 ksi) vs 600 MPa (87 ksi).

Which condition does FabDigit quote by default, +AT or +CG?

+AT is the default 1.4570 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose 1.4570 +AT over 1.4570 +CG?

Pick 1.4570 +AT when the part is bent, formed or impact-loaded, or when the part sees heat. Pick 1.4570 +CG when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 1.4570 +AT and 1.4570 +CG side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.