FabDigitFabDigit

Stainless Steel 1.4567 +AT vs 1.4567 +LC

Stainless Steel · 1.4567 temper comparison

1.4567 +AT and 1.4567 +LC are two conditions of the same stainless steel grade, 1.4567: +AT (solution annealed) versus +LC (light cold drawn). The chemistry is identical, so every difference below comes from the condition. 1.4567 +LC is the stronger of the two: yield strength 320 MPa (46.4 ksi) against 210 MPa (30.5 ksi) for 1.4567 +AT, about 52% more; tensile strength follows at 570 MPa (82.7 ksi) vs 520 MPa (75.4 ksi). In exchange, 1.4567 +AT is the more ductile: elongation 55% versus 40% for 1.4567 +LC, and 1.4567 +LC is harder (175 HB vs 150 HB). 1.4567 +AT runs hotter in service (550°C vs 400°C continuous).

1.4567 +ATChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

1.4567 +LCChoose it when strength drives the design.

1.4567 +AT vs 1.4567 +LC: properties

1.4567 +AT1.4567 +LC

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

520 MPa75.4 ksi
570 MPa82.7 ksi

Yield Strength (0.2% offset)

210 MPa30.5 ksi
320 MPa46.4 ksi

Elongation at Break

55%
40%

Reduction in Area

75%
68%

Compressive Strength

215 MPa31.2 ksi
330 MPa47.9 ksi

Shear Strength

380 MPa55.1 ksi
405 MPa58.7 ksi

Fatigue Strength (Endurance Limit)

240 MPa34.8 ksi
265 MPa38.4 ksi

Fracture Toughness (K_IC)

180 MPa·√m164 ksi·√in
165 MPa·√m150 ksi·√in

Charpy V-Notch Impact (RT)

160 J118 ft·lbf
140 J103 ft·lbf

Hardness, Brinell

150 HB
175 HB

Hardness, Rockwell B

80 HRB
88 HRB

Hardness, Vickers

160 HV
185 HV

Same in both: Elastic (Young's) Modulus 193 GPa28 Msi · Shear Modulus 77 GPa11.2 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Same in both: Density 7.9 g/cm³0.29 lb/in³ · Melting Point (Solidus) 1,400°C2,552 °F · Liquidus Temperature 1,450°C2,642 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

550°C1,022 °F
400°C752 °F

Same in both: Thermal Conductivity 16 W/m·K9.2 BTU/hr·ft·°F · Specific Heat Capacity 500 J/kg·K0.12 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 16.5 µm/m·K9.2 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Resistivity

7.3×10⁻⁷ Ω·m28.7 µΩ·in
7.4×10⁻⁷ Ω·m29.1 µΩ·in

Same in both: Electrical Conductivity 2.4 % IACS

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

58 / 100
56 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.08 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

38 / 100
42 / 100

Machinability Rating (AISI 1212 = 100 %)

45%
50%

Weldability

68 / 100
66 / 100

Formability (cold)

95 / 100
88 / 100

Same in both: Castability 40 / 100 · Brazeability / Solderability 70 / 100 · Polishability 80 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 53 MJ/kg22,786 BTU/lb · Embodied Carbon (primary production) 4.7 kg CO₂/kg · Embodied Water 180 L/kg21.6 gal/lb · Typical Recycled Content 60%

Strength versus weight

Yield strength against density for every stainless steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

3005007001,0001,5002,0007.27.47.67.888.2Density (g/cm³)Yield strength (MPa) — log scale1.4567

1.4567 +AT vs 1.4567 +LC — frequently asked

Is 1.4567 +LC stronger than 1.4567 +AT?

Yes. 1.4567 +LC has a typical yield strength of 320 MPa (46.4 ksi) against 210 MPa (30.5 ksi) for 1.4567 +AT — about 52% more. Tensile strength is 570 MPa (82.7 ksi) vs 520 MPa (75.4 ksi).

Which condition does FabDigit quote by default, +AT or +LC?

+AT is the default 1.4567 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose 1.4567 +AT over 1.4567 +LC?

Pick 1.4567 +AT when the part is bent, formed or impact-loaded, or when the part sees heat. Pick 1.4567 +LC when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 1.4567 +AT and 1.4567 +LC side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.