1.4539-CD and 1.4539 FORGED-AT are two conditions of the same stainless steel grade, 1.4539: CD (cold drawn) versus FORGED-AT (forged + solution annealed). The chemistry is identical, so every difference below comes from the condition. 1.4539-CD is the stronger of the two: yield strength 480 MPa (69.6 ksi) against 250 MPa (36.3 ksi) for 1.4539 FORGED-AT, about 92% more; tensile strength follows at 720 MPa (104 ksi) vs 580 MPa (84.1 ksi). In exchange, 1.4539 FORGED-AT is the more ductile: elongation 43% versus 28% for 1.4539-CD, and 1.4539-CD is harder (220 HB vs 160 HB). 1.4539 FORGED-AT runs hotter in service (400°C vs 350°C continuous).

1.4539-CDChoose it when strength drives the design.

1.4539 FORGED-ATChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

1.4539-CD vs 1.4539 FORGED-AT: properties

1.4539-CD1.4539 FORGED-AT

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

720 MPa104 ksi
580 MPa84.1 ksi

Yield Strength (0.2% offset)

480 MPa69.6 ksi
250 MPa36.3 ksi

Elongation at Break

28%
43%

Reduction in Area

55%
62%

Shear Strength

440 MPa63.8 ksi
370 MPa53.7 ksi

Fatigue Strength (Endurance Limit)

310 MPa45 ksi
250 MPa36.3 ksi

Fracture Toughness (K_IC)

150 MPa·√m137 ksi·√in
200 MPa·√m182 ksi·√in

Charpy V-Notch Impact (RT)

120 J88.5 ft·lbf
170 J125 ft·lbf

Hardness, Brinell

220 HB
160 HB

Hardness, Rockwell B

96 HRB
82 HRB

Hardness, Vickers

232 HV
170 HV

Same in both: Elastic (Young's) Modulus 195 GPa28.3 Msi · Shear Modulus 75 GPa10.9 Msi · Bulk Modulus 163 GPa23.6 Msi · Poisson's Ratio 0.3

Physical

Density and transition temperatures.

Same in both: Density 7.95 g/cm³0.29 lb/in³ · Melting Point (Solidus) 1,320°C2,408 °F · Liquidus Temperature 1,390°C2,534 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

350°C662 °F
400°C752 °F

Same in both: Thermal Conductivity 11.5 W/m·K6.6 BTU/hr·ft·°F · Specific Heat Capacity 450 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 15.8 µm/m·K8.8 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 1.7 % IACS · Electrical Resistivity 1×10⁻⁶ Ω·m39.4 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

76 / 100
78 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.05 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

32 / 100
28 / 100

Machinability Rating (AISI 1212 = 100 %)

35%
30%

Weldability

76 / 100
80 / 100

Formability (cold)

60 / 100
72 / 100

Same in both: Brazeability / Solderability 55 / 100 · Polishability 80 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 88 MJ/kg37,833 BTU/lb · Embodied Carbon (primary production) 6.5 kg CO₂/kg · Embodied Water 220 L/kg26.4 gal/lb · Typical Recycled Content 60%

Strength versus weight

Yield strength against density for every stainless steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

3005007001,0001,5002,0007.27.47.67.888.2Density (g/cm³)Yield strength (MPa) — log scale1.4539

1.4539-CD vs 1.4539 FORGED-AT — frequently asked

Is 1.4539-CD stronger than 1.4539 FORGED-AT?

Yes. 1.4539-CD has a typical yield strength of 480 MPa (69.6 ksi) against 250 MPa (36.3 ksi) for 1.4539 FORGED-AT — about 92% more. Tensile strength is 720 MPa (104 ksi) vs 580 MPa (84.1 ksi).

Which condition does FabDigit quote by default, CD or FORGED-AT?

AT is the default 1.4539 condition in the FabDigit quote flow (neither CD nor FORGED-AT). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose 1.4539-CD over 1.4539 FORGED-AT?

Pick 1.4539-CD when strength drives the design. Pick 1.4539 FORGED-AT when the part is bent, formed or impact-loaded, or when the part sees heat.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 1.4539-CD and 1.4539 FORGED-AT side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.