FabDigitFabDigit

Stainless Steel 1.4462-CD vs 1.4462 WELD-SA

Stainless Steel · 1.4462 temper comparison

1.4462-CD and 1.4462 WELD-SA are two conditions of the same stainless steel grade, 1.4462: CD (cold drawn) versus WELD-SA (welded tube/pipe, solution annealed after welding). The chemistry is identical, so every difference below comes from the condition. 1.4462-CD is the stronger of the two: yield strength 660 MPa (95.7 ksi) against 520 MPa (75.4 ksi) for 1.4462 WELD-SA, about 27% more; tensile strength follows at 860 MPa (125 ksi) vs 750 MPa (109 ksi). In exchange, 1.4462 WELD-SA is the more ductile: elongation 28% versus 22% for 1.4462-CD, and 1.4462-CD is harder (280 HB vs 250 HB).

1.4462-CDChoose it when strength drives the design.

1.4462 WELD-SAChoose it when the part is bent, formed or impact-loaded.

1.4462-CD vs 1.4462 WELD-SA: properties

1.4462-CD1.4462 WELD-SA

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

860 MPa125 ksi
750 MPa109 ksi

Yield Strength (0.2% offset)

660 MPa95.7 ksi
520 MPa75.4 ksi

Elongation at Break

22%
28%

Reduction in Area

48%
55%

Compressive Strength

670 MPa97.2 ksi
520 MPa75.4 ksi

Shear Strength

515 MPa74.7 ksi
450 MPa65.3 ksi

Fatigue Strength (Endurance Limit)

460 MPa66.7 ksi
400 MPa58 ksi

Fracture Toughness (K_IC)

100 MPa·√m91 ksi·√in
110 MPa·√m100 ksi·√in

Charpy V-Notch Impact (RT)

120 J88.5 ft·lbf
160 J118 ft·lbf

Hardness, Brinell

280 HB
250 HB

Hardness, Rockwell C

29 HRC
25 HRC

Hardness, Vickers

295 HV
260 HV

Same in both: Elastic (Young's) Modulus 200 GPa29 Msi · Shear Modulus 77 GPa11.2 Msi · Bulk Modulus 165 GPa23.9 Msi · Poisson's Ratio 0.3

Physical

Density and transition temperatures.

Same in both: Density 7.8 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,385°C2,525 °F · Liquidus Temperature 1,445°C2,633 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 15 W/m·K8.7 BTU/hr·ft·°F · Specific Heat Capacity 480 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 13 µm/m·K7.2 µin/in·°F · Latent Heat of Fusion 260 J/g112 BTU/lb · Max Service Temperature (continuous) 250°C482 °F · Min Service Temperature -50°C-58 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 2.2 % IACS · Electrical Resistivity 8×10⁻⁷ Ω·m31.5 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

76 / 100
77 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.05 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

33 / 100
30 / 100

Machinability Rating (AISI 1212 = 100 %)

22%
20%

Weldability

70 / 100
72 / 100

Formability (cold)

30 / 100
42 / 100

Same in both: Brazeability / Solderability 40 / 100 · Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 62 MJ/kg26,655 BTU/lb · Embodied Carbon (primary production) 4.5 kg CO₂/kg · Embodied Water 200 L/kg24 gal/lb · Typical Recycled Content 70%

Strength versus weight

Yield strength against density for every stainless steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

3005007001,0001,5002,0007.27.47.67.888.2Density (g/cm³)Yield strength (MPa) — log scale1.4462

1.4462-CD vs 1.4462 WELD-SA — frequently asked

Is 1.4462-CD stronger than 1.4462 WELD-SA?

Yes. 1.4462-CD has a typical yield strength of 660 MPa (95.7 ksi) against 520 MPa (75.4 ksi) for 1.4462 WELD-SA — about 27% more. Tensile strength is 860 MPa (125 ksi) vs 750 MPa (109 ksi).

Which condition does FabDigit quote by default, CD or WELD-SA?

SA is the default 1.4462 condition in the FabDigit quote flow (neither CD nor WELD-SA). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose 1.4462-CD over 1.4462 WELD-SA?

Pick 1.4462-CD when strength drives the design. Pick 1.4462 WELD-SA when the part is bent, formed or impact-loaded.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 1.4462-CD and 1.4462 WELD-SA side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.