FabDigitFabDigit

Stainless Steel 1.4449-CD vs 1.4449-HR

Stainless Steel · 1.4449 temper comparison

1.4449-CD and 1.4449-HR are two conditions of the same stainless steel grade, 1.4449: CD (cold drawn) versus HR (hot rolled). The chemistry is identical, so every difference below comes from the condition. 1.4449-CD is the stronger of the two: yield strength 450 MPa (65.3 ksi) against 250 MPa (36.3 ksi) for 1.4449-HR, about 80% more; tensile strength follows at 690 MPa (100 ksi) vs 540 MPa (78.3 ksi). In exchange, 1.4449-HR is the more ductile: elongation 45% versus 25% for 1.4449-CD, and 1.4449-CD is harder (210 HB vs 155 HB). 1.4449-HR runs hotter in service (800°C vs 425°C continuous).

1.4449-CDChoose it when strength drives the design.

1.4449-HRChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

1.4449-CD vs 1.4449-HR: properties

1.4449-CD1.4449-HR

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

690 MPa100 ksi
540 MPa78.3 ksi

Yield Strength (0.2% offset)

450 MPa65.3 ksi
250 MPa36.3 ksi

Elongation at Break

25%
45%

Reduction in Area

45%
65%

Compressive Strength

450 MPa65.3 ksi
250 MPa36.3 ksi

Shear Strength

480 MPa69.6 ksi
405 MPa58.7 ksi

Fatigue Strength (Endurance Limit)

300 MPa43.5 ksi
230 MPa33.4 ksi

Fracture Toughness (K_IC)

130 MPa·√m118 ksi·√in
180 MPa·√m164 ksi·√in

Charpy V-Notch Impact (RT)

80 J59 ft·lbf
120 J88.5 ft·lbf

Hardness, Brinell

210 HB
155 HB

Hardness, Rockwell B

95 HRB
79 HRB

Hardness, Vickers

225 HV
165 HV

Same in both: Elastic (Young's) Modulus 200 GPa29 Msi · Shear Modulus 77 GPa11.2 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.3

Physical

Density and transition temperatures.

Same in both: Density 8 g/cm³0.29 lb/in³ · Melting Point (Solidus) 1,370°C2,498 °F · Liquidus Temperature 1,400°C2,552 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

425°C797 °F
800°C1,472 °F

Same in both: Thermal Conductivity 15 W/m·K8.7 BTU/hr·ft·°F · Specific Heat Capacity 500 J/kg·K0.12 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 16 µm/m·K8.9 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 2.3 % IACS · Electrical Resistivity 7.5×10⁻⁷ Ω·m29.5 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

74 / 100
76 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.05 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

48 / 100
40 / 100

Machinability Rating (AISI 1212 = 100 %)

50%
43%

Weldability

80 / 100
85 / 100

Formability (cold)

55 / 100
80 / 100

Polishability

80 / 100
60 / 100

Same in both: Castability 45 / 100 · Brazeability / Solderability 60 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 53 MJ/kg22,786 BTU/lb · Embodied Carbon (primary production) 4.6 kg CO₂/kg · Embodied Water 120 L/kg14.4 gal/lb · Typical Recycled Content 60%

Strength versus weight

Yield strength against density for every stainless steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

3005007001,0001,5002,0007.27.47.67.888.2Density (g/cm³)Yield strength (MPa) — log scale1.4449

1.4449-CD vs 1.4449-HR — frequently asked

Is 1.4449-CD stronger than 1.4449-HR?

Yes. 1.4449-CD has a typical yield strength of 450 MPa (65.3 ksi) against 250 MPa (36.3 ksi) for 1.4449-HR — about 80% more. Tensile strength is 690 MPa (100 ksi) vs 540 MPa (78.3 ksi).

Which condition does FabDigit quote by default, CD or HR?

AT is the default 1.4449 condition in the FabDigit quote flow (neither CD nor HR). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 1.4449-CD or 1.4449-HR?

1.4449-CD, by a small margin. Both rate fair for machinability — 48/100 against 40/100 for 1.4449-HR; for welding the order is 1.4449-HR first (excellent, 85/100) then 1.4449-CD (very good, 80/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in 1.4449-CD and 1.4449-HR side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.