FabDigitFabDigit

Stainless Steel 1.4319 3/4H vs 1.4319 Annealed

Stainless Steel · 1.4319 temper comparison

1.4319 3/4H and 1.4319 Annealed are two conditions of the same stainless steel grade, 1.4319: 3/4H (three-quarter hard) versus Annealed. The chemistry is identical, so every difference below comes from the condition. 1.4319 3/4H is the stronger of the two: yield strength 960 MPa (139 ksi) against 290 MPa (42.1 ksi) for 1.4319 Annealed, about 3.3 times as much; tensile strength follows at 1,230 MPa (178 ksi) vs 700 MPa (102 ksi). In exchange, 1.4319 Annealed is the more ductile: elongation 55% versus 12% for 1.4319 3/4H, and 1.4319 3/4H is harder (345 HB vs 170 HB). 1.4319 Annealed runs hotter in service (800°C vs 300°C continuous). On the shop floor, 1.4319 Annealed machines more easily (fair vs poor) and 1.4319 Annealed welds better (very good vs good).

1.4319 3/4HChoose it when strength drives the design.

1.4319 AnnealedChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

1.4319 3/4H vs 1.4319 Annealed: properties

1.4319 3/4H1.4319 Annealed

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

200 GPa29 Msi
195 GPa28.3 Msi

Tensile Strength (Ultimate)

1,230 MPa178 ksi
700 MPa102 ksi

Yield Strength (0.2% offset)

960 MPa139 ksi
290 MPa42.1 ksi

Elongation at Break

12%
55%

Reduction in Area

35%
68%

Compressive Strength

960 MPa139 ksi
290 MPa42.1 ksi

Shear Strength

740 MPa107 ksi
450 MPa65.3 ksi

Fatigue Strength (Endurance Limit)

500 MPa72.5 ksi
280 MPa40.6 ksi

Fracture Toughness (K_IC)

75 MPa·√m68.3 ksi·√in
150 MPa·√m137 ksi·√in

Charpy V-Notch Impact (RT)

35 J25.8 ft·lbf
150 J111 ft·lbf

Hardness, Brinell

345 HB
170 HB

Hardness, Vickers

370 HV
180 HV

Same in both: Shear Modulus 77 GPa11.2 Msi · Bulk Modulus 152 GPa22 Msi · Poisson's Ratio 0.3 · Hardness, Rockwell B 88 HRB

Physical

Density and transition temperatures.

Same in both: Density 7.9 g/cm³0.29 lb/in³ · Melting Point (Solidus) 1,400°C2,552 °F · Liquidus Temperature 1,450°C2,642 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

15 W/m·K8.7 BTU/hr·ft·°F
15.5 W/m·K9 BTU/hr·ft·°F

Max Service Temperature (continuous)

300°C572 °F
800°C1,472 °F

Same in both: Specific Heat Capacity 500 J/kg·K0.12 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 16.5 µm/m·K9.2 µin/in·°F · Latent Heat of Fusion 280 J/g120 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

2.3 % IACS
2.4 % IACS

Electrical Resistivity

7.4×10⁻⁷ Ω·m29.1 µΩ·in
7.3×10⁻⁷ Ω·m28.7 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

50 / 100
55 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.1 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

30 / 100
40 / 100

Machinability Rating (AISI 1212 = 100 %)

35%
45%

Weldability

55 / 100
70 / 100

Formability (cold)

38 / 100
88 / 100

Same in both: Brazeability / Solderability 60 / 100 · Polishability 75 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 53 MJ/kg22,786 BTU/lb · Embodied Carbon (primary production) 5 kg CO₂/kg · Embodied Water 250 L/kg30 gal/lb · Typical Recycled Content 60%

Strength versus weight

Yield strength against density for every stainless steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

3005007001,0001,5002,0007.27.47.67.888.2Density (g/cm³)Yield strength (MPa) — log scale1.4319

1.4319 3/4H vs 1.4319 Annealed — frequently asked

Is 1.4319 3/4H stronger than 1.4319 Annealed?

Yes. 1.4319 3/4H has a typical yield strength of 960 MPa (139 ksi) against 290 MPa (42.1 ksi) for 1.4319 Annealed — about 3.3 times as much. Tensile strength is 1,230 MPa (178 ksi) vs 700 MPa (102 ksi).

Which condition does FabDigit quote by default, 3/4H or Annealed?

Annealed is the default 1.4319 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 1.4319 3/4H or 1.4319 Annealed?

1.4319 Annealed. Its machinability rates fair (40/100) against poor (30/100) for 1.4319 3/4H; for welding the order is 1.4319 Annealed first (very good, 70/100) then 1.4319 3/4H (good, 55/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in 1.4319 3/4H and 1.4319 Annealed side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.