FabDigitFabDigit

Stainless Steel 1.4313 +A vs 1.4313 +QT700

Stainless Steel · 1.4313 temper comparison

1.4313 +A and 1.4313 +QT700 are two conditions of the same stainless steel grade, 1.4313: +A (annealed) versus +QT700 (quenched and tempered, Rm 700–900 MPa). The chemistry is identical, so every difference below comes from the condition. 1.4313 +QT700 is the stronger of the two: yield strength 620 MPa (89.9 ksi) against 550 MPa (79.8 ksi) for 1.4313 +A, about 13% more; tensile strength follows at 790 MPa (115 ksi) vs 750 MPa (109 ksi).

1.4313 +QT700Choose it when strength drives the design.

1.4313 +A vs 1.4313 +QT700: properties

1.4313 +A1.4313 +QT700

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

750 MPa109 ksi
790 MPa115 ksi

Yield Strength (0.2% offset)

550 MPa79.8 ksi
620 MPa89.9 ksi

Elongation at Break

18%
19%

Reduction in Area

55%
62%

Fatigue Strength (Endurance Limit)

340 MPa49.3 ksi
375 MPa54.4 ksi

Fracture Toughness (K_IC)

150 MPa·√m137 ksi·√in
165 MPa·√m150 ksi·√in

Charpy V-Notch Impact (RT)

60 J44.3 ft·lbf
115 J84.8 ft·lbf

Hardness, Brinell

250 HB
240 HB

Hardness, Rockwell C

24 HRC
23 HRC

Hardness, Vickers

262 HV
252 HV

Same in both: Elastic (Young's) Modulus 200 GPa29 Msi · Shear Modulus 77 GPa11.2 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.3 · Compressive Strength 710 MPa103 ksi · Shear Strength 520 MPa75.4 ksi

Physical

Density and transition temperatures.

Same in both: Density 7.7 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,440°C2,624 °F · Liquidus Temperature 1,500°C2,732 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

400°C752 °F
430°C806 °F

Same in both: Thermal Conductivity 25 W/m·K14.4 BTU/hr·ft·°F · Specific Heat Capacity 440 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 10.5 µm/m·K5.8 µin/in·°F · Latent Heat of Fusion 260 J/g112 BTU/lb · Min Service Temperature -80°C-112 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 2.9 % IACS · Electrical Resistivity 6×10⁻⁷ Ω·m23.6 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

44 / 100
47 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.28 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

45 / 100
38 / 100

Machinability Rating (AISI 1212 = 100 %)

45%
38%

Weldability

72 / 100
70 / 100

Formability (cold)

45 / 100
36 / 100

Same in both: Castability 70 / 100 · Brazeability / Solderability 45 / 100 · Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 53 MJ/kg22,786 BTU/lb · Embodied Carbon (primary production) 4.8 kg CO₂/kg · Embodied Water 220 L/kg26.4 gal/lb · Typical Recycled Content 60%

Strength versus weight

Yield strength against density for every stainless steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

3005007001,0001,5002,0007.27.47.67.888.2Density (g/cm³)Yield strength (MPa) — log scale1.4313

1.4313 +A vs 1.4313 +QT700 — frequently asked

Is 1.4313 +QT700 stronger than 1.4313 +A?

Yes. 1.4313 +QT700 has a typical yield strength of 620 MPa (89.9 ksi) against 550 MPa (79.8 ksi) for 1.4313 +A — about 13% more. Tensile strength is 790 MPa (115 ksi) vs 750 MPa (109 ksi).

Which condition does FabDigit quote by default, +A or +QT700?

+QT780 is the default 1.4313 condition in the FabDigit quote flow (neither +A nor +QT700). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 1.4313 +A or 1.4313 +QT700?

1.4313 +A, by a small margin. Both rate fair for machinability — 45/100 against 38/100 for 1.4313 +QT700.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 1.4313 +A and 1.4313 +QT700 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.