Stainless Steel 1.4162-CD vs 1.4162 REBAR-CW
Stainless Steel · 1.4162 temper comparison
1.4162-CD and 1.4162 REBAR-CW are two conditions of the same stainless steel grade, 1.4162: CD (cold drawn) versus REBAR-CW (cold worked deformed reinforcing bar). The chemistry is identical, so every difference below comes from the condition. Both yield at about 680 MPa — the mechanical properties are the same, and the difference is in how the stock is processed and what it is certified to (cold drawn versus cold worked deformed reinforcing bar). 1.4162-CD is the more ductile: elongation 25% versus 22% for 1.4162 REBAR-CW, and 1.4162-CD is harder (26 HRC vs 24 HRC).
1.4162-CDChoose it when the part is bent, formed or impact-loaded.
1.4162-CD vs 1.4162 REBAR-CW: propertiesHow to read these bars
- One bar per material. A full bar is the highest value among all stainless steel grades in the FabDigit library; each bar is drawn as a share of that.
- The better value (by the usual engineering direction) is in bold. Rows with no direction — density, thermal conductivity — have no bold.
- Values are typical room-temperature figures for the condition named on each card.
- Confirm against the certified mill or resin datasheet before design release.
How to read these bars
- One bar per material. A full bar is the highest value among all stainless steel grades in the FabDigit library; each bar is drawn as a share of that.
- The better value (by the usual engineering direction) is in bold. Rows with no direction — density, thermal conductivity — have no bold.
- Values are typical room-temperature figures for the condition named on each card.
- Confirm against the certified mill or resin datasheet before design release.
Mechanical
Strength, stiffness, ductility and hardness at room temperature.
Tensile Strength (Ultimate)
Yield Strength (0.2% offset)
Elongation at Break
Reduction in Area
Compressive Strength
Shear Strength
Fatigue Strength (Endurance Limit)
Fracture Toughness (K_IC)
Charpy V-Notch Impact (RT)
Hardness, Brinell
Hardness, Rockwell B
Hardness, Rockwell C
Hardness, Vickers
Same in both: Elastic (Young's) Modulus 200 GPa29 Msi · Shear Modulus 77 GPa11.2 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.3
Physical
Density and transition temperatures.
Same in both: Density 7.75 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,420°C2,588 °F · Liquidus Temperature 1,465°C2,669 °F
Thermal
How each material carries heat and how hot it can run.
Same in both: Thermal Conductivity 15 W/m·K8.7 BTU/hr·ft·°F · Specific Heat Capacity 500 J/kg·K0.12 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 13 µm/m·K7.2 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Max Service Temperature (continuous) 300°C572 °F · Min Service Temperature -50°C-58 °F
Electrical
Conductivity and insulation.
Same in both: Electrical Conductivity 2.2 % IACS · Electrical Resistivity 8×10⁻⁷ Ω·m31.5 µΩ·in
Chemical & Environmental
Corrosion and environmental resistance (0–100 scores).
Corrosion Resistance
Same in both: Galvanic Potential (seawater, vs SCE) -0.15 V
Manufacturability
FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.
Machinability
Machinability Rating (AISI 1212 = 100 %)
Formability (cold)
Same in both: Weldability 65 / 100 · Brazeability / Solderability 40 / 100 · Polishability 65 / 100
Sustainability
Primary-production footprint per kilogram.
Same in both: Embodied Energy (primary production) 48 MJ/kg20,636 BTU/lb · Embodied Carbon (primary production) 4.2 kg CO₂/kg · Embodied Water 150 L/kg18 gal/lb · Typical Recycled Content 75%
Strength versus weight
Yield strength against density for every stainless steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.
1.4162-CD vs 1.4162 REBAR-CW — frequently asked
What is the difference between 1.4162-CD and 1.4162 REBAR-CW?
1.4162-CD and 1.4162 REBAR-CW are two conditions of the same stainless steel grade, 1.4162: CD (cold drawn) versus REBAR-CW (cold worked deformed reinforcing bar). The chemistry is identical, so every difference below comes from the condition. Both yield at about 680 MPa — the mechanical properties are the same, and the difference is in how the stock is processed and what it is certified to (cold drawn versus cold worked deformed reinforcing bar).
Which condition does FabDigit quote by default, CD or REBAR-CW?
ANN is the default 1.4162 condition in the FabDigit quote flow (neither CD nor REBAR-CW). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.
Which is easier to machine, 1.4162-CD or 1.4162 REBAR-CW?
1.4162-CD, by a small margin. Both rate fair for machinability — 42/100 against 35/100 for 1.4162 REBAR-CW.
Ready to make it?
Upload a CAD file and FabDigit prices the part in 1.4162-CD and 1.4162 REBAR-CW side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.
Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.