FabDigitFabDigit

Solder & Low-Melting Alloy Antimonial Lead 6%-O vs Antimonial Lead 6% ROLLED

Solder & Low-Melting Alloy · Antimonial Lead 6% temper comparison

Antimonial Lead 6%-O and Antimonial Lead 6% ROLLED are two conditions of the same solder & low-melting alloy grade, Antimonial Lead 6%: O (annealed) versus ROLLED (cold rolled sheet / plate). The chemistry is identical, so every difference below comes from the condition. Antimonial Lead 6% ROLLED is the stronger of the two: yield strength 30 MPa (4.35 ksi) against 20 MPa (2.9 ksi) for Antimonial Lead 6%-O, about 50% more; tensile strength follows at 55 MPa (7.98 ksi) vs 45 MPa (6.53 ksi). In exchange, Antimonial Lead 6%-O is the more ductile: elongation 40% versus 30% for Antimonial Lead 6% ROLLED, and Antimonial Lead 6% ROLLED is harder (14 HB vs 11 HB).

Antimonial Lead 6%-OChoose it when the part is bent, formed or impact-loaded.

Antimonial Lead 6% ROLLEDChoose it when strength drives the design.

Antimonial Lead 6%-O vs Antimonial Lead 6% ROLLED: properties

Antimonial Lead 6%-OAntimonial Lead 6% ROLLED

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

45 MPa6.5 ksi
55 MPa8 ksi

Yield Strength (0.2% offset)

20 MPa2.9 ksi
30 MPa4.4 ksi

Elongation at Break

40%
30%

Reduction in Area

45%
35%

Shear Strength

33 MPa4.8 ksi
40 MPa5.8 ksi

Fatigue Strength (Endurance Limit)

11 MPa1.6 ksi
14 MPa2 ksi

Hardness, Brinell

11 HB
14 HB

Hardness, Vickers

12 HV
15 HV

Same in both: Elastic (Young's) Modulus 17 GPa2.5 Msi · Shear Modulus 6.2 GPa0.9 Msi · Bulk Modulus 44 GPa6.4 Msi · Poisson's Ratio 0.43

Physical

Density and transition temperatures.

Same in both: Density 10.88 g/cm³0.39 lb/in³ · Melting Point (Solidus) 252°C486 °F · Liquidus Temperature 281°C538 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

26 W/m·K15 BTU/hr·ft·°F
25 W/m·K14.4 BTU/hr·ft·°F

Max Service Temperature (continuous)

95°C203 °F
100°C212 °F

Same in both: Specific Heat Capacity 130 J/kg·K0.03 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 27 µm/m·K15 µin/in·°F · Latent Heat of Fusion 24 J/g10.3 BTU/lb · Min Service Temperature -60°C-76 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

6.6 % IACS
6 % IACS

Electrical Resistivity

2.6×10⁻⁷ Ω·m10.2 µΩ·in
2.9×10⁻⁷ Ω·m11.4 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

62 / 100
63 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.55 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

75 / 100
78 / 100

Machinability Rating (AISI 1212 = 100 %)

110%
115%

Formability (cold)

70 / 100
60 / 100

Same in both: Weldability 62 / 100 · Castability 88 / 100 · Brazeability / Solderability 78 / 100 · Polishability 25 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 27 MJ/kg11,608 BTU/lb · Embodied Carbon (primary production) 2.2 kg CO₂/kg · Embodied Water 130 L/kg15.6 gal/lb · Typical Recycled Content 65%

Strength versus weight

Yield strength against density for every solder & low-melting alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

125102050891011Density (g/cm³)Yield strength (MPa) — log scaleAntimonial Lead 6%

Antimonial Lead 6%-O vs Antimonial Lead 6% ROLLED — frequently asked

Is Antimonial Lead 6% ROLLED stronger than Antimonial Lead 6%-O?

Yes. Antimonial Lead 6% ROLLED has a typical yield strength of 30 MPa (4.35 ksi) against 20 MPa (2.9 ksi) for Antimonial Lead 6%-O — about 50% more. Tensile strength is 55 MPa (7.98 ksi) vs 45 MPa (6.53 ksi).

Which condition does FabDigit quote by default, O or ROLLED?

F is the default Antimonial Lead 6% condition in the FabDigit quote flow (neither O nor ROLLED). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose Antimonial Lead 6%-O over Antimonial Lead 6% ROLLED?

Pick Antimonial Lead 6%-O when the part is bent, formed or impact-loaded. Pick Antimonial Lead 6% ROLLED when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in Antimonial Lead 6%-O and Antimonial Lead 6% ROLLED side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.