FabDigitFabDigit

Solder & Low-Melting Alloy Antimonial Lead 6% Aged vs Antimonial Lead 6%-O

Solder & Low-Melting Alloy · Antimonial Lead 6% temper comparison

Antimonial Lead 6% Aged and Antimonial Lead 6%-O are two conditions of the same solder & low-melting alloy grade, Antimonial Lead 6%: Aged (cast + natural age hardening) versus O (annealed). The chemistry is identical, so every difference below comes from the condition. Antimonial Lead 6% Aged is the stronger of the two: yield strength 38 MPa (5.51 ksi) against 20 MPa (2.9 ksi) for Antimonial Lead 6%-O, about 90% more; tensile strength follows at 68 MPa (9.86 ksi) vs 45 MPa (6.53 ksi). In exchange, Antimonial Lead 6%-O is the more ductile: elongation 40% versus 14% for Antimonial Lead 6% Aged, and Antimonial Lead 6% Aged is harder (18 HB vs 11 HB).

Antimonial Lead 6% AgedChoose it when strength drives the design.

Antimonial Lead 6%-OChoose it when the part is bent, formed or impact-loaded.

Antimonial Lead 6% Aged vs Antimonial Lead 6%-O: properties

Antimonial Lead 6% AgedAntimonial Lead 6%-O

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

68 MPa9.9 ksi
45 MPa6.5 ksi

Yield Strength (0.2% offset)

38 MPa5.5 ksi
20 MPa2.9 ksi

Elongation at Break

14%
40%

Reduction in Area

16%
45%

Shear Strength

48 MPa7 ksi
33 MPa4.8 ksi

Fatigue Strength (Endurance Limit)

16 MPa2.3 ksi
11 MPa1.6 ksi

Hardness, Brinell

18 HB
11 HB

Hardness, Vickers

19 HV
12 HV

Same in both: Elastic (Young's) Modulus 17 GPa2.5 Msi · Shear Modulus 6.2 GPa0.9 Msi · Bulk Modulus 44 GPa6.4 Msi · Poisson's Ratio 0.43

Physical

Density and transition temperatures.

Same in both: Density 10.88 g/cm³0.39 lb/in³ · Melting Point (Solidus) 252°C486 °F · Liquidus Temperature 281°C538 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

25 W/m·K14.4 BTU/hr·ft·°F
26 W/m·K15 BTU/hr·ft·°F

Same in both: Specific Heat Capacity 130 J/kg·K0.03 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 27 µm/m·K15 µin/in·°F · Latent Heat of Fusion 24 J/g10.3 BTU/lb · Max Service Temperature (continuous) 95°C203 °F · Min Service Temperature -60°C-76 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

6 % IACS
6.6 % IACS

Electrical Resistivity

2.9×10⁻⁷ Ω·m11.4 µΩ·in
2.6×10⁻⁷ Ω·m10.2 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.55 V · Corrosion Resistance 62 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

83 / 100
75 / 100

Machinability Rating (AISI 1212 = 100 %)

125%
110%

Weldability

55 / 100
62 / 100

Formability (cold)

35 / 100
70 / 100

Same in both: Castability 88 / 100 · Brazeability / Solderability 78 / 100 · Polishability 25 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 27 MJ/kg11,608 BTU/lb · Embodied Carbon (primary production) 2.2 kg CO₂/kg · Embodied Water 130 L/kg15.6 gal/lb · Typical Recycled Content 65%

Strength versus weight

Yield strength against density for every solder & low-melting alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

125102050891011Density (g/cm³)Yield strength (MPa) — log scaleAntimonial Lead 6%

Antimonial Lead 6% Aged vs Antimonial Lead 6%-O — frequently asked

Is Antimonial Lead 6% Aged stronger than Antimonial Lead 6%-O?

Yes. Antimonial Lead 6% Aged has a typical yield strength of 38 MPa (5.51 ksi) against 20 MPa (2.9 ksi) for Antimonial Lead 6%-O — about 90% more. Tensile strength is 68 MPa (9.86 ksi) vs 45 MPa (6.53 ksi).

Which condition does FabDigit quote by default, Aged or O?

F is the default Antimonial Lead 6% condition in the FabDigit quote flow (neither Aged nor O). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, Antimonial Lead 6% Aged or Antimonial Lead 6%-O?

Antimonial Lead 6% Aged, by a small margin. Both rate very good for machinability — 83/100 against 75/100 for Antimonial Lead 6%-O; for welding the order is Antimonial Lead 6%-O first (good, 62/100) then Antimonial Lead 6% Aged (good, 55/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in Antimonial Lead 6% Aged and Antimonial Lead 6%-O side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.