FabDigitFabDigit

Refractory Metal R04251 Annealed vs R04251-SR

Refractory Metal · R04251 temper comparison

R04251 Annealed and R04251-SR are two conditions of the same refractory metal grade, R04251: Annealed versus SR (stress relieved). The chemistry is identical, so every difference below comes from the condition. R04251-SR is the stronger of the two: yield strength 260 MPa (37.7 ksi) against 140 MPa (20.3 ksi) for R04251 Annealed, about 86% more; tensile strength follows at 340 MPa (49.3 ksi) vs 250 MPa (36.3 ksi). In exchange, R04251 Annealed is the more ductile: elongation 30% versus 18% for R04251-SR, and R04251-SR is harder (140 HV vs 100 HV).

R04251 AnnealedChoose it when the part is bent, formed or impact-loaded.

R04251-SRChoose it when strength drives the design.

R04251 Annealed vs R04251-SR: properties

R04251 AnnealedR04251-SR

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

250 MPa36.3 ksi
340 MPa49.3 ksi

Yield Strength (0.2% offset)

140 MPa20.3 ksi
260 MPa37.7 ksi

Elongation at Break

30%
18%

Reduction in Area

80%
65%

Shear Strength

160 MPa23.2 ksi
210 MPa30.5 ksi

Fatigue Strength (Endurance Limit)

130 MPa18.9 ksi
170 MPa24.7 ksi

Hardness, Rockwell B

58 HRB
75 HRB

Hardness, Vickers

100 HV
140 HV

Same in both: Elastic (Young's) Modulus 100 GPa14.5 Msi · Shear Modulus 37 GPa5.4 Msi · Bulk Modulus 170 GPa24.7 Msi · Poisson's Ratio 0.38

Physical

Density and transition temperatures.

Same in both: Density 8.6 g/cm³0.31 lb/in³ · Melting Point (Solidus) 2,410°C4,370 °F · Liquidus Temperature 2,450°C4,442 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

45 W/m·K26 BTU/hr·ft·°F
44 W/m·K25.4 BTU/hr·ft·°F

Same in both: Specific Heat Capacity 270 J/kg·K0.06 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 7.2 µm/m·K4 µin/in·°F · Latent Heat of Fusion 288 J/g124 BTU/lb · Max Service Temperature (continuous) 400°C752 °F · Min Service Temperature -253°C-423 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

8.5 % IACS
8.3 % IACS

Electrical Resistivity

2×10⁻⁷ Ω·m7.87 µΩ·in
2.08×10⁻⁷ Ω·m8.19 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.2 V · Corrosion Resistance 85 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

28 / 100
32 / 100

Machinability Rating (AISI 1212 = 100 %)

25%
27%

Weldability

80 / 100
78 / 100

Formability (cold)

90 / 100
65 / 100

Same in both: Castability 20 / 100 · Brazeability / Solderability 60 / 100 · Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 900 MJ/kg386,931 BTU/lb · Embodied Carbon (primary production) 55 kg CO₂/kg · Embodied Water 600 L/kg71.9 gal/lb · Typical Recycled Content 15%

Strength versus weight

Yield strength against density for every refractory metal grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

1502003005007001,0001,5005101520Density (g/cm³)Yield strength (MPa) — log scaleR04251

R04251 Annealed vs R04251-SR — frequently asked

Is R04251-SR stronger than R04251 Annealed?

Yes. R04251-SR has a typical yield strength of 260 MPa (37.7 ksi) against 140 MPa (20.3 ksi) for R04251 Annealed — about 86% more. Tensile strength is 340 MPa (49.3 ksi) vs 250 MPa (36.3 ksi).

Which condition does FabDigit quote by default, Annealed or SR?

Annealed is the default R04251 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose R04251 Annealed over R04251-SR?

Pick R04251 Annealed when the part is bent, formed or impact-loaded. Pick R04251-SR when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in R04251 Annealed and R04251-SR side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.