FabDigitFabDigit

Precious Metal Pt90Ir10-H04 vs Pt90Ir10-SR

Precious Metal · Pt90Ir10 temper comparison

Pt90Ir10-H04 and Pt90Ir10-SR are two conditions of the same precious metal grade, Pt90Ir10: H04 (full hard) versus SR (stress relieved). The chemistry is identical, so every difference below comes from the condition. Pt90Ir10-H04 is the stronger of the two: yield strength 830 MPa (120 ksi) against 480 MPa (69.6 ksi) for Pt90Ir10-SR, about 73% more; tensile strength follows at 950 MPa (138 ksi) vs 620 MPa (89.9 ksi). In exchange, Pt90Ir10-SR is the more ductile: elongation 10% versus 2.5% for Pt90Ir10-H04, and Pt90Ir10-H04 is harder (245 HB vs 166 HB). Pt90Ir10-SR runs hotter in service (800°C vs 500°C continuous). On the shop floor, Pt90Ir10-SR welds better (good vs fair).

Pt90Ir10-H04Choose it when strength drives the design.

Pt90Ir10-SRChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

Pt90Ir10-H04 vs Pt90Ir10-SR: properties

Pt90Ir10-H04Pt90Ir10-SR

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

205 GPa29.7 Msi
200 GPa29 Msi

Tensile Strength (Ultimate)

950 MPa138 ksi
620 MPa89.9 ksi

Yield Strength (0.2% offset)

830 MPa120 ksi
480 MPa69.6 ksi

Elongation at Break

2.5%
10%

Shear Strength

570 MPa82.7 ksi
390 MPa56.6 ksi

Hardness, Brinell

245 HB
166 HB

Hardness, Rockwell B

100 HRB
86 HRB

Hardness, Vickers

260 HV
175 HV

Same in both: Shear Modulus 72 GPa10.4 Msi · Bulk Modulus 255 GPa37 Msi · Poisson's Ratio 0.39

Physical

Density and transition temperatures.

Same in both: Density 21.54 g/cm³0.78 lb/in³ · Melting Point (Solidus) 1,780°C3,236 °F · Liquidus Temperature 1,800°C3,272 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

29.5 W/m·K17 BTU/hr·ft·°F
30.8 W/m·K17.8 BTU/hr·ft·°F

Max Service Temperature (continuous)

500°C932 °F
800°C1,472 °F

Same in both: Specific Heat Capacity 133 J/kg·K0.03 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 8.8 µm/m·K4.9 µin/in·°F · Latent Heat of Fusion 118 J/g50.7 BTU/lb · Min Service Temperature -269°C-452 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

6.6 % IACS
6.9 % IACS

Electrical Resistivity

2.62×10⁻⁷ Ω·m10.3 µΩ·in
2.52×10⁻⁷ Ω·m9.92 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) 0.25 V · Corrosion Resistance 99 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

35 / 100
29 / 100

Machinability Rating (AISI 1212 = 100 %)

28%
24%

Weldability

50 / 100
68 / 100

Formability (cold)

25 / 100
55 / 100

Same in both: Castability 40 / 100 · Brazeability / Solderability 60 / 100 · Polishability 92 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 250,000 MJ/kg1.07×10⁸ BTU/lb · Embodied Carbon (primary production) 14,500 kg CO₂/kg · Embodied Water 260,000 L/kg31,155 gal/lb · Typical Recycled Content 45%

Strength versus weight

Yield strength against density for every precious metal grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

50100200500101520Density (g/cm³)Yield strength (MPa) — log scalePt90Ir10

Pt90Ir10-H04 vs Pt90Ir10-SR — frequently asked

Is Pt90Ir10-H04 stronger than Pt90Ir10-SR?

Yes. Pt90Ir10-H04 has a typical yield strength of 830 MPa (120 ksi) against 480 MPa (69.6 ksi) for Pt90Ir10-SR — about 73% more. Tensile strength is 950 MPa (138 ksi) vs 620 MPa (89.9 ksi).

Which condition does FabDigit quote by default, H04 or SR?

Annealed is the default Pt90Ir10 condition in the FabDigit quote flow (neither H04 nor SR). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, Pt90Ir10-H04 or Pt90Ir10-SR?

Pt90Ir10-H04. Its machinability rates fair (35/100) against poor (29/100) for Pt90Ir10-SR; for welding the order is Pt90Ir10-SR first (good, 68/100) then Pt90Ir10-H04 (fair, 50/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in Pt90Ir10-H04 and Pt90Ir10-SR side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.