Pt90Ir10-H01 and Pt90Ir10-H04 are two conditions of the same precious metal grade, Pt90Ir10: H01 (quarter hard) versus H04 (full hard). The chemistry is identical, so every difference below comes from the condition. Pt90Ir10-H04 is the stronger of the two: yield strength 830 MPa (120 ksi) against 420 MPa (60.9 ksi) for Pt90Ir10-H01, about 98% more; tensile strength follows at 950 MPa (138 ksi) vs 550 MPa (79.8 ksi). In exchange, Pt90Ir10-H01 is the more ductile: elongation 12% versus 2.5% for Pt90Ir10-H04, and Pt90Ir10-H04 is harder (245 HB vs 143 HB). Pt90Ir10-H01 runs hotter in service (600°C vs 500°C continuous). On the shop floor, Pt90Ir10-H01 welds better (good vs fair).

Pt90Ir10-H01Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

Pt90Ir10-H04Choose it when strength drives the design.

Pt90Ir10-H01 vs Pt90Ir10-H04: properties

Pt90Ir10-H01Pt90Ir10-H04

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

200 GPa29 Msi
205 GPa29.7 Msi

Tensile Strength (Ultimate)

550 MPa79.8 ksi
950 MPa138 ksi

Yield Strength (0.2% offset)

420 MPa60.9 ksi
830 MPa120 ksi

Elongation at Break

12%
2.5%

Shear Strength

350 MPa50.8 ksi
570 MPa82.7 ksi

Hardness, Brinell

143 HB
245 HB

Hardness, Rockwell B

79 HRB
100 HRB

Hardness, Vickers

150 HV
260 HV

Same in both: Shear Modulus 72 GPa10.4 Msi · Bulk Modulus 255 GPa37 Msi · Poisson's Ratio 0.39

Physical

Density and transition temperatures.

Same in both: Density 21.54 g/cm³0.78 lb/in³ · Melting Point (Solidus) 1,780°C3,236 °F · Liquidus Temperature 1,800°C3,272 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

30.5 W/m·K17.6 BTU/hr·ft·°F
29.5 W/m·K17 BTU/hr·ft·°F

Max Service Temperature (continuous)

600°C1,112 °F
500°C932 °F

Same in both: Specific Heat Capacity 133 J/kg·K0.03 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 8.8 µm/m·K4.9 µin/in·°F · Latent Heat of Fusion 118 J/g50.7 BTU/lb · Min Service Temperature -269°C-452 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

6.8 % IACS
6.6 % IACS

Electrical Resistivity

2.55×10⁻⁷ Ω·m10 µΩ·in
2.62×10⁻⁷ Ω·m10.3 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) 0.25 V · Corrosion Resistance 99 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

28 / 100
35 / 100

Machinability Rating (AISI 1212 = 100 %)

23%
28%

Weldability

65 / 100
50 / 100

Formability (cold)

60 / 100
25 / 100

Same in both: Castability 40 / 100 · Brazeability / Solderability 60 / 100 · Polishability 92 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 250,000 MJ/kg1.07×10⁸ BTU/lb · Embodied Carbon (primary production) 14,500 kg CO₂/kg · Embodied Water 260,000 L/kg31,155 gal/lb · Typical Recycled Content 45%

Strength versus weight

Yield strength against density for every precious metal grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

50100200500101520Density (g/cm³)Yield strength (MPa) — log scalePt90Ir10

Pt90Ir10-H01 vs Pt90Ir10-H04 — frequently asked

Is Pt90Ir10-H04 stronger than Pt90Ir10-H01?

Yes. Pt90Ir10-H04 has a typical yield strength of 830 MPa (120 ksi) against 420 MPa (60.9 ksi) for Pt90Ir10-H01 — about 98% more. Tensile strength is 950 MPa (138 ksi) vs 550 MPa (79.8 ksi).

Which condition does FabDigit quote by default, H01 or H04?

Annealed is the default Pt90Ir10 condition in the FabDigit quote flow (neither H01 nor H04). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, Pt90Ir10-H01 or Pt90Ir10-H04?

Pt90Ir10-H04. Its machinability rates fair (35/100) against poor (28/100) for Pt90Ir10-H01; for welding the order is Pt90Ir10-H01 first (good, 65/100) then Pt90Ir10-H04 (fair, 50/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in Pt90Ir10-H01 and Pt90Ir10-H04 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.