FabDigitFabDigit

Precious Metal IC-Ag99.95 Cast vs IC-Ag99.95-H08

Precious Metal · IC-Ag99.95 temper comparison

IC-Ag99.95 Cast and IC-Ag99.95-H08 are two conditions of the same precious metal grade, IC-Ag99.95: Cast (as cast) versus H08 (spring hard). The chemistry is identical, so every difference below comes from the condition. IC-Ag99.95-H08 is the stronger of the two: yield strength 320 MPa (46.4 ksi) against 45 MPa (6.53 ksi) for IC-Ag99.95 Cast, about 7.1 times as much; tensile strength follows at 360 MPa (52.2 ksi) vs 130 MPa (18.9 ksi). In exchange, IC-Ag99.95 Cast is the more ductile: elongation 35% versus 2% for IC-Ag99.95-H08, and IC-Ag99.95-H08 is harder (102 HB vs 25 HB). IC-Ag99.95-H08 is stiffer (78 GPa vs 74 GPa) and IC-Ag99.95 Cast runs hotter in service (300°C vs 130°C continuous). On the shop floor, IC-Ag99.95-H08 machines more easily (good vs fair) and IC-Ag99.95 Cast welds better (very good vs good).

IC-Ag99.95 CastChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

IC-Ag99.95-H08Choose it when strength drives the design, or when the part is machined in volume.

IC-Ag99.95 Cast vs IC-Ag99.95-H08: properties

IC-Ag99.95 CastIC-Ag99.95-H08

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

74 GPa10.7 Msi
78 GPa11.3 Msi

Tensile Strength (Ultimate)

130 MPa18.9 ksi
360 MPa52.2 ksi

Yield Strength (0.2% offset)

45 MPa6.5 ksi
320 MPa46.4 ksi

Elongation at Break

35%
2%

Reduction in Area

50%
6%

Shear Strength

100 MPa14.5 ksi
215 MPa31.2 ksi

Fatigue Strength (Endurance Limit)

55 MPa8 ksi
130 MPa18.9 ksi

Hardness, Brinell

25 HB
102 HB

Hardness, Vickers

27 HV
108 HV

Same in both: Shear Modulus 29 GPa4.2 Msi · Bulk Modulus 100 GPa14.5 Msi · Poisson's Ratio 0.37

Physical

Density and transition temperatures.

Same in both: Density 10.49 g/cm³0.38 lb/in³ · Melting Point (Solidus) 962°C1,763 °F · Liquidus Temperature 962°C1,763 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

429 W/m·K248 BTU/hr·ft·°F
415 W/m·K240 BTU/hr·ft·°F

Max Service Temperature (continuous)

300°C572 °F
130°C266 °F

Same in both: Specific Heat Capacity 235 J/kg·K0.06 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 19.5 µm/m·K10.8 µin/in·°F · Latent Heat of Fusion 105 J/g45.1 BTU/lb · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

106 % IACS
102 % IACS

Electrical Resistivity

1.63×10⁻⁸ Ω·m0.642 µΩ·in
1.69×10⁻⁸ Ω·m0.665 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) 0.05 V · Corrosion Resistance 82 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

45 / 100
55 / 100

Machinability Rating (AISI 1212 = 100 %)

50%
60%

Weldability

75 / 100
65 / 100

Formability (cold)

92 / 100
25 / 100

Same in both: Castability 85 / 100 · Brazeability / Solderability 97 / 100 · Polishability 95 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 1,600 MJ/kg687,877 BTU/lb · Embodied Carbon (primary production) 110 kg CO₂/kg · Embodied Water 2,500 L/kg300 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every precious metal grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

50100200500101520Density (g/cm³)Yield strength (MPa) — log scaleIC-Ag99.95

IC-Ag99.95 Cast vs IC-Ag99.95-H08 — frequently asked

Is IC-Ag99.95-H08 stronger than IC-Ag99.95 Cast?

Yes. IC-Ag99.95-H08 has a typical yield strength of 320 MPa (46.4 ksi) against 45 MPa (6.53 ksi) for IC-Ag99.95 Cast — about 7.1 times as much. Tensile strength is 360 MPa (52.2 ksi) vs 130 MPa (18.9 ksi).

Which condition does FabDigit quote by default, Cast or H08?

Cast is the default IC-Ag99.95 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, IC-Ag99.95 Cast or IC-Ag99.95-H08?

IC-Ag99.95-H08. Its machinability rates good (55/100) against fair (45/100) for IC-Ag99.95 Cast; for welding the order is IC-Ag99.95 Cast first (very good, 75/100) then IC-Ag99.95-H08 (good, 65/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in IC-Ag99.95 Cast and IC-Ag99.95-H08 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.