FabDigitFabDigit

Precious Metal B617-H02 vs B617-O

Precious Metal · B617 temper comparison

B617-H02 and B617-O are two conditions of the same precious metal grade, B617: H02 (half hard) versus O (annealed). The chemistry is identical, so every difference below comes from the condition. B617-H02 is the stronger of the two: yield strength 240 MPa (34.8 ksi) against 65 MPa (9.43 ksi) for B617-O, about 3.7 times as much; tensile strength follows at 345 MPa (50 ksi) vs 265 MPa (38.4 ksi). In exchange, B617-O is the more ductile: elongation 40% versus 20% for B617-H02, and B617-H02 is harder (86 HB vs 58 HB). B617-O runs hotter in service (200°C vs 150°C continuous).

B617-H02Choose it when strength drives the design.

B617-OChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

B617-H02 vs B617-O: properties

B617-H02B617-O

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

345 MPa50 ksi
265 MPa38.4 ksi

Yield Strength (0.2% offset)

240 MPa34.8 ksi
65 MPa9.4 ksi

Elongation at Break

20%
40%

Shear Strength

215 MPa31.2 ksi
175 MPa25.4 ksi

Fatigue Strength (Endurance Limit)

125 MPa18.1 ksi
95 MPa13.8 ksi

Hardness, Brinell

86 HB
58 HB

Hardness, Vickers

90 HV
60 HV

Same in both: Elastic (Young's) Modulus 79 GPa11.5 Msi · Shear Modulus 29 GPa4.2 Msi · Bulk Modulus 100 GPa14.5 Msi · Poisson's Ratio 0.37 · Reduction in Area 70%

Physical

Density and transition temperatures.

Same in both: Density 10.31 g/cm³0.37 lb/in³ · Melting Point (Solidus) 779°C1,434 °F · Liquidus Temperature 875°C1,607 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

356 W/m·K206 BTU/hr·ft·°F
360 W/m·K208 BTU/hr·ft·°F

Max Service Temperature (continuous)

150°C302 °F
200°C392 °F

Same in both: Specific Heat Capacity 237 J/kg·K0.06 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 18.7 µm/m·K10.4 µin/in·°F · Latent Heat of Fusion 105 J/g45.1 BTU/lb · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

84 % IACS
85 % IACS

Same in both: Electrical Resistivity 2.03×10⁻⁸ Ω·m0.799 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) 0.05 V · Corrosion Resistance 78 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

60 / 100
55 / 100

Formability (cold)

72 / 100
92 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 55% · Weldability 55 / 100 · Castability 72 / 100 · Brazeability / Solderability 95 / 100 · Polishability 95 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 1,500 MJ/kg644,885 BTU/lb · Embodied Carbon (primary production) 100 kg CO₂/kg · Embodied Water 3,000 L/kg359 gal/lb · Typical Recycled Content 45%

Strength versus weight

Yield strength against density for every precious metal grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

50100200500101520Density (g/cm³)Yield strength (MPa) — log scaleB617

B617-H02 vs B617-O — frequently asked

Is B617-H02 stronger than B617-O?

Yes. B617-H02 has a typical yield strength of 240 MPa (34.8 ksi) against 65 MPa (9.43 ksi) for B617-O — about 3.7 times as much. Tensile strength is 345 MPa (50 ksi) vs 265 MPa (38.4 ksi).

Which condition does FabDigit quote by default, H02 or O?

O is the default B617 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, B617-H02 or B617-O?

B617-H02, by a small margin. Both rate good for machinability — 60/100 against 55/100 for B617-O.

Ready to make it?

Upload a CAD file and FabDigit prices the part in B617-H02 and B617-O side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.