Nickel Beryllium 360-H and Nickel Beryllium 360-TH04 are two conditions of the same nickel alloy grade, Nickel Beryllium 360: H (hardened) versus TH04 (TD04 and precipitation hardened). The chemistry is identical, so every difference below comes from the condition. Nickel Beryllium 360-TH04 is the stronger of the two: yield strength 1,650 MPa (239 ksi) against 970 MPa (141 ksi) for Nickel Beryllium 360-H, about 70% more; tensile strength follows at 1,900 MPa (276 ksi) vs 1,140 MPa (165 ksi). In exchange, Nickel Beryllium 360-H is the more ductile: elongation 6% versus 3% for Nickel Beryllium 360-TH04, and Nickel Beryllium 360-TH04 is harder (57 HRC vs 33 HRC). Nickel Beryllium 360-TH04 runs hotter in service (400°C vs 300°C continuous) and Nickel Beryllium 360-TH04 conducts heat better (48 W/m·K vs 30 W/m·K). On the shop floor, Nickel Beryllium 360-H machines more easily (30 vs 18 out of 100) and Nickel Beryllium 360-H welds better (fair vs poor).

Nickel Beryllium 360-HChoose it when the part is bent, formed or impact-loaded, or when the part is machined in volume.

Nickel Beryllium 360-TH04Choose it when strength drives the design, or when the part sees heat.

Nickel Beryllium 360-H vs Nickel Beryllium 360-TH04: properties

Nickel Beryllium 360-HNickel Beryllium 360-TH04

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

200 GPa29 Msi
207 GPa30 Msi

Tensile Strength (Ultimate)

1,140 MPa165 ksi
1,900 MPa276 ksi

Yield Strength (0.2% offset)

970 MPa141 ksi
1,650 MPa239 ksi

Elongation at Break

6%
3%

Reduction in Area

25%
15%

Shear Strength

690 MPa100 ksi
1,050 MPa152 ksi

Fatigue Strength (Endurance Limit)

420 MPa60.9 ksi
560 MPa81.2 ksi

Charpy V-Notch Impact (RT)

25 J18.4 ft·lbf
12 J8.9 ft·lbf

Hardness, Rockwell C

33 HRC
57 HRC

Hardness, Vickers

330 HV
640 HV

Same in both: Shear Modulus 79 GPa11.5 Msi · Bulk Modulus 171 GPa24.8 Msi · Poisson's Ratio 0.3 · Compressive Strength 1,250 MPa181 ksi

Physical

Density and transition temperatures.

Same in both: Density 8.26 g/cm³0.3 lb/in³ · Melting Point (Solidus) 1,300°C2,372 °F · Liquidus Temperature 1,370°C2,498 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

30 W/m·K17.3 BTU/hr·ft·°F
48 W/m·K27.7 BTU/hr·ft·°F

Thermal Expansion (CTE, 20–100 °C)

13.5 µm/m·K7.5 µin/in·°F
13.2 µm/m·K7.3 µin/in·°F

Max Service Temperature (continuous)

300°C572 °F
400°C752 °F

Same in both: Specific Heat Capacity 420 J/kg·K0.1 BTU/lb·°F · Latent Heat of Fusion 295 J/g127 BTU/lb · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

5 % IACS
7 % IACS

Electrical Resistivity

3.4×10⁻⁷ Ω·m13.4 µΩ·in
2.5×10⁻⁷ Ω·m9.84 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

62 / 100
65 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.15 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

30 / 100
18 / 100

Machinability Rating (AISI 1212 = 100 %)

20%
15%

Weldability

45 / 100
30 / 100

Formability (cold)

35 / 100
8 / 100

Polishability

75 / 100
85 / 100

Same in both: Castability 45 / 100 · Brazeability / Solderability 45 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 320 MJ/kg137,575 BTU/lb · Embodied Carbon (primary production) 22 kg CO₂/kg · Embodied Water 600 L/kg71.9 gal/lb · Typical Recycled Content 20%

Strength versus weight

Yield strength against density for every nickel alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0006.577.588.59Density (g/cm³)Yield strength (MPa) — log scaleNickel Beryllium 360

Nickel Beryllium 360-H vs Nickel Beryllium 360-TH04 — frequently asked

Is Nickel Beryllium 360-TH04 stronger than Nickel Beryllium 360-H?

Yes. Nickel Beryllium 360-TH04 has a typical yield strength of 1,650 MPa (239 ksi) against 970 MPa (141 ksi) for Nickel Beryllium 360-H — about 70% more. Tensile strength is 1,900 MPa (276 ksi) vs 1,140 MPa (165 ksi).

Which condition does FabDigit quote by default, H or TH04?

AT is the default Nickel Beryllium 360 condition in the FabDigit quote flow (neither H nor TH04). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, Nickel Beryllium 360-H or Nickel Beryllium 360-TH04?

Nickel Beryllium 360-H, by a small margin. Both rate poor for machinability — 30/100 against 18/100 for Nickel Beryllium 360-TH04; for welding the order is Nickel Beryllium 360-H first (fair, 45/100) then Nickel Beryllium 360-TH04 (poor, 30/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in Nickel Beryllium 360-H and Nickel Beryllium 360-TH04 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.