FabDigitFabDigit

Nickel Alloy N10624-CD vs N10624-SA

Nickel Alloy · N10624 temper comparison

N10624-CD and N10624-SA are two conditions of the same nickel alloy grade, N10624: CD (cold drawn) versus SA (solution annealed). The chemistry is identical, so every difference below comes from the condition. N10624-CD is the stronger of the two: yield strength 700 MPa (102 ksi) against 400 MPa (58 ksi) for N10624-SA, about 75% more; tensile strength follows at 1,000 MPa (145 ksi) vs 890 MPa (129 ksi). In exchange, N10624-SA is the more ductile: elongation 55% versus 30% for N10624-CD, and N10624-CD is harder (260 HB vs 210 HB). N10624-SA runs hotter in service (480°C vs 430°C continuous).

N10624-CDChoose it when strength drives the design.

N10624-SAChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

N10624-CD vs N10624-SA: properties

N10624-CDN10624-SA

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

1,000 MPa145 ksi
890 MPa129 ksi

Yield Strength (0.2% offset)

700 MPa102 ksi
400 MPa58 ksi

Elongation at Break

30%
55%

Reduction in Area

40%
60%

Shear Strength

610 MPa88.5 ksi
540 MPa78.3 ksi

Fatigue Strength (Endurance Limit)

400 MPa58 ksi
350 MPa50.8 ksi

Charpy V-Notch Impact (RT)

110 J81.1 ft·lbf
180 J133 ft·lbf

Hardness, Brinell

260 HB
210 HB

Hardness, Rockwell B

100 HRB
95 HRB

Hardness, Vickers

275 HV
220 HV

Same in both: Elastic (Young's) Modulus 216 GPa31.3 Msi · Shear Modulus 83 GPa12 Msi · Bulk Modulus 190 GPa27.6 Msi · Poisson's Ratio 0.31

Physical

Density and transition temperatures.

Same in both: Density 9.22 g/cm³0.33 lb/in³ · Melting Point (Solidus) 1,330°C2,426 °F · Liquidus Temperature 1,380°C2,516 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

430°C806 °F
480°C896 °F

Same in both: Thermal Conductivity 11 W/m·K6.4 BTU/hr·ft·°F · Specific Heat Capacity 373 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 10.3 µm/m·K5.7 µin/in·°F · Latent Heat of Fusion 290 J/g125 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 1.3 % IACS · Electrical Resistivity 1.37×10⁻⁶ Ω·m53.9 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

85 / 100
88 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.12 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

25 / 100
20 / 100

Machinability Rating (AISI 1212 = 100 %)

15%
12%

Weldability

60 / 100
65 / 100

Formability (cold)

45 / 100
70 / 100

Same in both: Castability 35 / 100 · Brazeability / Solderability 55 / 100 · Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 145 MJ/kg62,339 BTU/lb · Embodied Carbon (primary production) 13.5 kg CO₂/kg · Embodied Water 300 L/kg35.9 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every nickel alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0006.577.588.59Density (g/cm³)Yield strength (MPa) — log scaleN10624

N10624-CD vs N10624-SA — frequently asked

Is N10624-CD stronger than N10624-SA?

Yes. N10624-CD has a typical yield strength of 700 MPa (102 ksi) against 400 MPa (58 ksi) for N10624-SA — about 75% more. Tensile strength is 1,000 MPa (145 ksi) vs 890 MPa (129 ksi).

Which condition does FabDigit quote by default, CD or SA?

SA is the default N10624 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, N10624-CD or N10624-SA?

N10624-CD, by a small margin. Both rate poor for machinability — 25/100 against 20/100 for N10624-SA; for welding the order is N10624-SA first (good, 65/100) then N10624-CD (good, 60/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in N10624-CD and N10624-SA side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.