Nickel Alloy N07776 CW+A-120 vs N07776-STA

Nickel Alloy · N07776 temper comparison

N07776 CW+A-120 and N07776-STA are two conditions of the same nickel alloy grade, N07776: CW+A-120 (CW+A 120 ksi) versus STA (solution treated and aged). The chemistry is identical, so every difference below comes from the condition. N07776-STA is the stronger of the two: yield strength 1,010 MPa (146 ksi) against 880 MPa (128 ksi) for N07776 CW+A-120, about 15% more; tensile strength follows at 1,300 MPa (189 ksi) vs 1,170 MPa (170 ksi). In exchange, N07776 CW+A-120 is the more ductile: elongation 25% versus 22% for N07776-STA, and N07776-STA is harder (340 HB vs 302 HB).

N07776 CW+A-120Choose it when the part is bent, formed or impact-loaded.

N07776-STAChoose it when strength drives the design.

N07776 CW+A-120 vs N07776-STA: properties

N07776 CW+A-120N07776-STA

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

1,170 MPa170 ksi
1,300 MPa189 ksi

Yield Strength (0.2% offset)

880 MPa128 ksi
1,010 MPa146 ksi

Elongation at Break

25%
22%

Reduction in Area

45%
40%

Shear Strength

700 MPa102 ksi
780 MPa113 ksi

Fatigue Strength (Endurance Limit)

450 MPa65.3 ksi
500 MPa72.5 ksi

Fracture Toughness (K_IC)

115 MPa·√m105 ksi·√in
100 MPa·√m91 ksi·√in

Charpy V-Notch Impact (RT)

80 J59 ft·lbf
60 J44.3 ft·lbf

Hardness, Brinell

302 HB
340 HB

Hardness, Rockwell C

32 HRC
36 HRC

Hardness, Vickers

318 HV
360 HV

Same in both: Elastic (Young's) Modulus 204 GPa29.6 Msi · Shear Modulus 79 GPa11.5 Msi · Bulk Modulus 175 GPa25.4 Msi · Poisson's Ratio 0.31

Physical

Density and transition temperatures.

Same in both: Density 8.3 g/cm³0.3 lb/in³ · Melting Point (Solidus) 1,265°C2,309 °F · Liquidus Temperature 1,340°C2,444 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 10.8 W/m·K6.2 BTU/hr·ft·°F · Specific Heat Capacity 435 J/kg·K0.1 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12.8 µm/m·K7.1 µin/in·°F · Latent Heat of Fusion 290 J/g125 BTU/lb · Max Service Temperature (continuous) 650°C1,202 °F · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 1.4 % IACS · Electrical Resistivity 1.25×10⁻⁶ Ω·m49.2 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

88 / 100
86 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.1 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

17 / 100
15 / 100

Machinability Rating (AISI 1212 = 100 %)

14%
12%

Formability (cold)

26 / 100
25 / 100

Same in both: Weldability 40 / 100 · Brazeability / Solderability 50 / 100 · Polishability 75 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 215 MJ/kg92,433 BTU/lb · Embodied Carbon (primary production) 14.5 kg CO₂/kg · Embodied Water 400 L/kg47.9 gal/lb · Typical Recycled Content 35%

Strength versus weight

Yield strength against density for every nickel alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0006.577.588.59Density (g/cm³)Yield strength (MPa) — log scaleN07776

N07776 CW+A-120 vs N07776-STA — frequently asked

Is N07776-STA stronger than N07776 CW+A-120?

Yes. N07776-STA has a typical yield strength of 1,010 MPa (146 ksi) against 880 MPa (128 ksi) for N07776 CW+A-120 — about 15% more. Tensile strength is 1,300 MPa (189 ksi) vs 1,170 MPa (170 ksi).

Which condition does FabDigit quote by default, CW+A-120 or STA?

STA is the default N07776 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose N07776 CW+A-120 over N07776-STA?

Pick N07776 CW+A-120 when the part is bent, formed or impact-loaded. Pick N07776-STA when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in N07776 CW+A-120 and N07776-STA side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.