FabDigitFabDigit

Nickel Alloy N06210-CD vs N06210-HF

Nickel Alloy · N06210 temper comparison

N06210-CD and N06210-HF are two conditions of the same nickel alloy grade, N06210: CD (cold drawn) versus HF (hot Finished / Hot Worked and Annealed). The chemistry is identical, so every difference below comes from the condition. N06210-CD is the stronger of the two: yield strength 620 MPa (89.9 ksi) against 300 MPa (43.5 ksi) for N06210-HF, about 107% more; tensile strength follows at 860 MPa (125 ksi) vs 680 MPa (98.6 ksi). In exchange, N06210-HF is the more ductile: elongation 42% versus 25% for N06210-CD, and N06210-CD is harder (240 HB vs 175 HB). N06210-HF runs hotter in service (1,150°C vs 550°C continuous). On the shop floor, N06210-HF welds better (very good vs good).

N06210-CDChoose it when strength drives the design.

N06210-HFChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

N06210-CD vs N06210-HF: properties

N06210-CDN06210-HF

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

208 GPa30.2 Msi
210 GPa30.5 Msi

Tensile Strength (Ultimate)

860 MPa125 ksi
680 MPa98.6 ksi

Yield Strength (0.2% offset)

620 MPa89.9 ksi
300 MPa43.5 ksi

Elongation at Break

25%
42%

Reduction in Area

40%
52%

Compressive Strength

640 MPa92.8 ksi
300 MPa43.5 ksi

Shear Strength

540 MPa78.3 ksi
450 MPa65.3 ksi

Fatigue Strength (Endurance Limit)

345 MPa50 ksi
280 MPa40.6 ksi

Charpy V-Notch Impact (RT)

80 J59 ft·lbf
120 J88.5 ft·lbf

Hardness, Brinell

240 HB
175 HB

Hardness, Rockwell B

99 HRB
86 HRB

Hardness, Vickers

252 HV
184 HV

Same in both: Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 175 GPa25.4 Msi · Poisson's Ratio 0.31

Physical

Density and transition temperatures.

Same in both: Density 7.9 g/cm³0.29 lb/in³ · Melting Point (Solidus) 1,350°C2,462 °F · Liquidus Temperature 1,400°C2,552 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

550°C1,022 °F
1,150°C2,102 °F

Same in both: Thermal Conductivity 11.5 W/m·K6.6 BTU/hr·ft·°F · Specific Heat Capacity 450 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 13 µm/m·K7.2 µin/in·°F · Latent Heat of Fusion 290 J/g125 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Resistivity

1.23×10⁻⁶ Ω·m48.4 µΩ·in
1.22×10⁻⁶ Ω·m48 µΩ·in

Same in both: Electrical Conductivity 1.4 % IACS

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

76 / 100
77 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

20 / 100
18 / 100

Machinability Rating (AISI 1212 = 100 %)

14%
12%

Weldability

60 / 100
70 / 100

Formability (cold)

35 / 100
55 / 100

Same in both: Brazeability / Solderability 60 / 100 · Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 200 MJ/kg85,985 BTU/lb · Embodied Carbon (primary production) 14 kg CO₂/kg · Embodied Water 380 L/kg45.5 gal/lb · Typical Recycled Content 40%

Strength versus weight

Yield strength against density for every nickel alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0006.577.588.59Density (g/cm³)Yield strength (MPa) — log scaleN06210

N06210-CD vs N06210-HF — frequently asked

Is N06210-CD stronger than N06210-HF?

Yes. N06210-CD has a typical yield strength of 620 MPa (89.9 ksi) against 300 MPa (43.5 ksi) for N06210-HF — about 107% more. Tensile strength is 860 MPa (125 ksi) vs 680 MPa (98.6 ksi).

Which condition does FabDigit quote by default, CD or HF?

SA is the default N06210 condition in the FabDigit quote flow (neither CD nor HF). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which welds better, N06210-CD or N06210-HF?

N06210-HF. Its weldability rates very good (70/100) against good (60/100) for N06210-CD.

Ready to make it?

Upload a CAD file and FabDigit prices the part in N06210-CD and N06210-HF side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.